Search Submissions ๐Ÿ”Ž

Results for "liver function": 18 found

A GUI-Based Python Platform for the Quantification of Pre-Clinical Planar Optical Imaging Using 3D Anatomical Information

Authors: Bryan Bednarz, Malick Bio Idrissou, Campbell Haasch, Reinier Hernandez

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsinโ€“Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: Quantitative optical imaging is a powerful tool in murine models for assessing tumor growth and metastatic spread using bioluminescence imaging (BLI) and for detecting radiopharmaceutical upt...

An Adaptive Radiotherapy Approach Sparing Preirradiated Critical Structures

Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...

Contrast-Dependent Loss of Edge Sharpness in Low-Contrast Targets with Increasing Iterative Reconstruction Strength

Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Enhanced Predictive Model for Toxicity and 3-Year Survival in HCC Patients Using Learning Health System Infrastructure and AI-Driven Statistical Profiling

Authors: Ameer Elaimy, Theodore Lawrence, Charles S. Mayo, Seyyedeh Azar Oliaei Motlagh, Benjamin S. Rosen

Affiliation: University of Michigan

Abstract Preview: Purpose: To analyze the impact of clinical features on short-term survival, toxicity, and poor outcomes in HCC patients treated with SBRT,using automated data aggregation and enhanced algorithms with ...

Evaluating DNA Damage Efficacy for 90y and 225ac Based Radiotherapy

Authors: Ramin Abolfath, Alejandro Bertolet, Kofi M. Deh, Rao Khan, Vanessa Sanders, Daniel Suarez-Garcia

Affiliation: Massachusetts General Hospital and Harvard Medical School, University of Sevilla, Brookhaven National Laboratory, Howard University

Abstract Preview: Purpose: To compare the efficacy of 225Ac to 90Y for local cancer therapy by quantifying DNA damage using Monte Carlo simulations.
Methods: The TOPAS n-Bio toolkit was used to simulate the irradiat...

First-Time Live Imaging of Radiopharmaceutical Administration with a Hybrid Compton Camera

Authors: Ramesh Boggula, Jay W. Burmeister

Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine

Abstract Preview: Purpose: This study evaluated the performance of a hybrid Compton camera for real-time imaging during the administration of Lu-177-based radiopharmaceuticals, including Pluvicto and Lutathera. The aim...

Functional Liver Image Guided Radiation Planning Using MRI with a Contrast Agent

Authors: Kenneth L. Homann, Natalie A Lockney, Hong Zhang

Affiliation: Department of Radiation Oncology, Vanderbilt University Medical Center, Vanderbilt University Medical Center

Abstract Preview: Purpose: The aim of this study is to develop a treatment planning methodology utilizing liver functional imaging via contrast-enhanced Magnetic Resonance Imaging (MRI) in patients undergoing stereotac...

Graph Neural Network with Long Short-Term Memory for CT-Based Macrotrabecular-Massive Hepatocellular Carcinoma Diagnosis

Authors: Enhui Chang, Yunfei Dong, Yifei Hao, Chengliang Jin, Shengsheng Lai, Yi Long, Mengni Wu, Yulu Wu, Ruimeng Yang, Zhenyu Yang, Yue Yuan, Lei Zhang, Wanli Zhang, Yaogong Zhang

Affiliation: Duke Kunshan University, Department of Radiology, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Macrotrabecular-Massive Hepatocellular Carcinoma (MTM-HCC) is one type of liver cancer showed minimum image signature for accurate non-invasive diagnosis. This study aims to develop and evalu...

Impact of Transfer Learning on Estimation of Intravoxel Incoherent Motion Parameters in the Liver

Authors: Marissa Brown, Geoffrey D. Clarke, Luke Norton

Affiliation: University of Texas Health Science Center at San Antonio

Abstract Preview: Purpose: To evaluate how different learning strategies affect convolutional neural network (CNN) estimates of the liver's intravoxel incoherent motion (IVIM) parameters.
Methods: A 3-stage U-Net wa...

Interplay of Relative Biological Effectiveness and Dose Rate in Eye Plaque Brachytherapy with Low Energy Photons

Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart

Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington

Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...

MR-Based Functional Liver Imaging and Dosimetry to Predict Albi Change Post-SBRT

Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei

Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan

Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...

Minimizing Abscopal Effects in Normal Tissues with Flash-RT: Mechanisms of Action and Potential Clinical Applications

Authors: Liang Cui, Xingyu Lu, Hang Shang, LingHong Zhou

Affiliation: Southern Medical University

Abstract Preview: Purpose: This study examines how varying dose rates of radiotherapy impact normal tissues outside the target area and analyzes the protective effects and regulatory mechanisms of ultra-high dose rate ...

Multi-Path Deep Learning Model for Predicting Post-Radiotherapy Functional Liver Imaging in Patients with Hepatocellular Carcinoma

Authors: Smith Apisarnthanarax, Stephen R. Bowen, Sunan Cui, Jie Fu, Clemens Grassberger, Yulun He, Yejin Kim, Matthew J. Nyflot, Sharon Pai

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington, University of Washington and Fred Hutchinson Cancer Center

Abstract Preview: Purpose: 99mTc-sulfur colloid SPECT imaging enables quantitative assessment of voxel-wise liver function in patients with hepatocellular carcinoma (HCC). Accurately predicting post-radiotherapy (RT) l...

Performance Comparison of Artificial Intelligence-Based Auto-Segmentation Software on Pediatric CT Image Datasets for the Creation of Patient Specific Computational Phantoms

Authors: Wesley E. Bolch, Emily L. Marshall, Dhanashree Rajderkar, Wyatt Smither

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the accuracy of TotalSegmentator, an AI-based automatic segmentation toolkit, on pediatric CT scans as the original software was trained on adult image datasets with a mean patie...

Unidose: A Universal Framework for IMRT Dose Prediction

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Dose prediction (DP) is essential in guiding radiotherapy planning. However, current DP models for intensity-modulated radiation therapy (IMRT) primarily rely on fixed-beam orientations and a...

Using Single-Energy Bragg Peak (SEBP) Flash Combined with Intensity-Modulated Proton Therapy (IMPT) for Flash Treatment in a Clinical Synchrotron-Based Proton System

Authors: Chingyun Cheng, Ben Durkee, Carri K. Glide-Hurst, Minglei Kang, Haibo Lin, Bhudatt R. Paliwal, Charles B. Simone, Zhizhen Wei, Tengda Zhang, Xingyi Zhao

Affiliation: University of Wisconsin, Department of Mechanical Engineering, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Transmission Beam (TB), Single-Energy Bragg Peak (SEBP), and Single-Energy Spread-Out Bragg Peak (SESOBP) are primary proton conformal FLASH techniques. However, each comes with significant l...

Validation of a Simulation Tool and in-Silico Assessment of Low Contrast Detectability for Super-Resolution Deep Learning Reconstruction

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...