Search Submissions 🔎

Results for "liver lungs": 42 found

4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

A Dynamic Reconstruction and Motion Estimation Framework for Cardiorespiratory Motion-Resolved Real-Time Volumetric MR Imaging (DREME-MR)

Authors: Jie Deng, Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Based on a 3D pre-treatment MRI scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a moti...

An Efficient Workflow for X-Ray Imaging-Based IGRT/ART

Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...

An Energy Layer Optimization Approach for Spot Scanning Proton Arc Therapy

Authors: Wenhua Cao, Hadis Moazami Goudarzi, Madison Emily Grayson, Zongsheng Hu, Gino Lim, Steven Hsesheng Lin, Radhe Mohan

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Industrial Engineering, University of Houston, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) offers significant potential in treating complex cancer cases by delivering a continuous radiation dose as the gantry rotates. This study aims to investigate the pote...

Analysis of Inter-Organ Noise Variability for Clinical CT Images across 3133 Image Series

Authors: Lavsen Dahal, Francesco Ria, Ehsan Samei, Justin B. Solomon, Liesbeth Vancoillie, Yakun Zhang

Affiliation: Duke University, Carilion Clinic, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Clinical diagnostic task-based optimization of CT procedures require precise and organ-specific assessments. This study investigates inter-organ noise variability to highlight the limitations...

Automated Full-Body Tumor Segmentation from PET/CT Images

Authors: Austin Castelo, Xinru Chen, Caroline Chung, Laurence Edward Court, Jaganathan A Parameshwaran, Zhan Xu, Jinzhong Yang, Yao Zhao

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose:
To develop a deep learning-based segmentation model to automatically delineate tumors from full-body PET/CT images.
Methods:
PET/CT image pairs of 91 patients were collected for this...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

Clinical Validation of a Deep-Learning Segmentation Tool for Head and Neck Cancer Patients and Thoracic and Abdominal Cancer Patients

Authors: Haijian Chen, Katja M. Langen, William Andrew LePain, Claire Tran, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Georgia Institute of Technology

Abstract Preview: Purpose: To validate the performance of a commercial deep-learning segmentation (DLS) tool for head and neck cancer (HNC) and thoracic and abdominal cancer (TAC) by comparing it to manual segmentation...

Comparative Analysis of Soft Tissues and 3D Printing Materials Using Euclidean Distance for Linear Attenuation Coefficient

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Elsa Bifano Pimenta

Affiliation: University of São Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study evaluates the similarity between the linear attenuation coefficients of soft tissues and 3D printing materials in diagnostic imaging range using the Euclidean distance approach.

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Decreasing the Dependence of CT Number on the Position in the Field-of-View Using Photon Counting Detector CT

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...

Design and Testing of a Portable Microwave Scanner for Imaging Soft Tissue and Tumors in Cancer Patients

Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed

Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...

Development and Validation of an MR-Compatible Anthropomorphic Motion Phantom for Liver Motion Assessment and MR-Linac Gating System Optimization

Authors: Tsuicheng D. Chiu, Weiguo Lu, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: To develop and validate an MR-compatible anthropomorphic motion phantom to assess liver motion, real-time dosimetry, and gating system performance under controlled and reproducible respirator...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Dosimetric Comparison of Lattice and 3D Grid VMAT Planning for Spatially Fractionated Radiotherapy

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to conduct a dosimetric comparison between lattice radiotherapy (LRT) and 3D grid treatment planning techniques, focusing on their differences in delivering three-dimensional ...

Evaluating Commercial Auto-Segmentation Software: Is Performance on Pediatric Organs-at-Risk Accurate?

Authors: Gregory T. Armstrong, James E. Bates, Lei Dong, Ralph Ermoian, Jie Fu, Christine Hill-Kayser, Rebecca M. Howell, Sharareh Koufigar, John T. Lucas, Thomas E. Merchant, Tucker J. Netherton, Sogand Sadeghi

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Epidemiology and Cancer Control, St. Jude Children’s Research Hospital, St. Jude Children's Research Hospital, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiation Oncology, St. Jude Children’s Research Hospital, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, University of Washington/ Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study evaluates the adaptability and limitations of commercially available (MIM, RayStation) tools trained on predominately adult datasets (ages 20–60+ years) for delineating organs at r...

Evaluation of AI-Generated Synthetic 4DCT from 3DCT for Radiotherapy Planning

Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin

Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center

Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

From Concept to Clinic: A Phase-Based Approach for Implementing Auto-Segmentation in Radiation Therapy

Authors: Elizabeth L. Covington, Robert T. Dess, Charles S. Mayo, Michelle L. Mierzwa, Dan Polan, Jennifer Shah, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: Auto-segmentation improves contour consistency and standardization in radiation therapy but may introduce variations from current practices, potentially impacting treatment outcomes and toxic...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Image-Based Dosimetry for Tumor, Liver and Lungs in Y90 Radioembolization

Authors: Srinivas Cheenu Kappadath

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: N/A...

Impact of Arc Number Variation on VMAT Lattice Radiotherapy Plans

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to evaluate the effects of varying the number of arcs on treatment plans created using Volumetric Modulated Arc Therapy (VMAT) for Lattice radiotherapy (LRT).
Methods: Thre...

Influence of Treatment Site on Lung Shunt Fraction Estimation in 90y-Radioembolization Planning: Comparison of Planar and SPECT Imaging-Based Quantification

Authors: Lukas M. Carter, Jazmin Schwartz

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Accurate lung shunt fraction (LSF) estimation is essential for the safety and efficacy of 90Y-radioembolization therapy. This study compares planar gamma camera imaging and tomographic SPECT-...

Introduce a Novel Spot-Scanning Proton Arc(SPArc) Optimization Algorithm for Single Energy Extraction(SEE) Synchrotron-Accelerator-Based Proton Therapy System (PTS)

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Jiajian Shen

Affiliation: Department of Radiation Oncology, Mayo Clinic, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study aims to develop the first SPArc optimization algorithm based on the Dynamic Programming (SPArc-DP), to improve the treatment delivery efficiency for synchrotron-accelerator-based P...

PCA-Based Future Frame Prediction for Real-Time MRI-Guided Radiotherapy

Authors: B. Gino Fallone, Gawon Han, Keith D. Wachowicz, Mark G. Wright, Eugene Yip, Jihyun Yun

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com

Abstract Preview: Purpose: MRI-radiotherapy hybrid systems can guide the therapeutic beam, dynamically adjusting to a moving tumor in real-time. However, there is a time delay from imaging and beam control, requiring p...

Pipeline for Characterizing (Dosimetric) Impact of Respiratory Motion on Cardiac SBRT

Authors: Sarah Aubert, Leigh Conroy, Tony Tadic

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: Cardiac radioablation is an emerging non-invasive treatment option for patients with refractory or life-threatening ventricular tachycardia (VT), however it is difficult to deliver highly con...

Preclinical Assessment of 68ga-Dotatate As a Surrogate for 177lu-Dotatate Dose Distribution in Radionuclide Therapy

Authors: Payman Hejazi, Faraz Kalantari, Milad Peer-Firozjaei, Romina Pourhashem, Ehsan Tajikmansoury

Affiliation: Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Medical Physics, Semnan University of Medical Sciences, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose:
Pretreatment biodistribution imaging play a crucial role in optimizing tumors and organ absorbed doses estimation in radionuclide therapy. Surrogating radionuclides for more efficient trea...

Predicting Proton Therapy Dose Delivery Accuracy: A Machine Learning Approach Using Iroc’s Proton Phantom Data

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop a machine learning model for predicting dose delivery accuracy and identifying its key factors in IROC’s proton phantom program.
Methods: IROC’s proton QA program has six proton...

Prospective Organ-Level Dose Estimation in CT Imaging Using Scout-Net: A Comparison with Established Methods

Authors: Maria Jose Medrano, Grant Stevens, Liyan Sun, Justin Ruey Tse, Adam S. Wang, Sen Wang

Affiliation: Department of Radiology, Stanford University, GE HealthCare, Stanford University

Abstract Preview: Purpose: Patient exposure to ionizing radiation is a major concern in CT imaging. Size-specific dose estimation methods can prospectively estimate organ-level radiation doses based on patient sizes an...

Proton Pencil Beam Scanning Ultra-High Dose Rate 3D Lattice Radiotherapy: A Proof-of-Concept Flash Sfrt Study

Authors: Richard Bakst, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Minglei Kang, Nancy Y Lee, Haibo Lin, Hang Qi, Charles B. Simone, Pingfang Tsai, Milo Vermeulen, Shouyi Wei, Xiaodong Wu, Lee Xu, Irini Yacoub, Xingyi Zhao, Ajay Zheng

Affiliation: University of Miami, Peking University, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, icahn school of medicine at mount sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Three-dimensional lattice radiation therapy (3D-LRT) effectively achieves local tumor control with limited morbidity. Pencil beam scanning (PBS) proton therapy provides precise dose confor...

Quantitative Analysis of Dose Perturbation from Gantry Rotational Errors in Dynamic Spot-Scanning Proton Arc Therapy (SPArc)

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose:
This study investigates the dosimetric impact of systematic and random gantry position errors (GPE) during dynamic Spot-Scanning Proton Arc Therapy (SPArc) delivery.
Methods:
Four ca...

Rectangular Aperture-Based Beam Orientation Optimization for 4π Non-Coplanar Small Animal IMRT Delivery

Authors: Dante PI Capaldi, Lu Jiang, Qihui Lyu, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Preclinical small animal studies help understand radiation-induced biological responses, toxicities, and mechanisms, facilitating the translation of new therapies to patient treatment. Int...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Supercomputing-Enabled CT Virtual Imaging Trials: A Population-Scale Pilot Study

Authors: Ehsan Abadi, Zakaria Aboulbanine, Nicholas D Felice, David Fenwick, Anuj J. Kapadia, Cindy Marie McCabe, Jayasai Ram Rajagopal, Ehsan Samei

Affiliation: Duke University, Oak Ridge National Laboratory, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose:
Virtual imaging trials (VITs) offer a computational alternative to clinical imaging trials leveraging virtual patients, scanners, and interpreters to assess imaging questions. To provide m...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...

Using Contrast-Enhanced Computed Tomography for Non-Invasive Lung Shunt Fraction Prediction in Yttrium-90 Radioembolization

Authors: Roger Eric Goldman, Adrianna Imani Johnson Carter, Talia Marx, Brahim Mehadji, Emilie Roncali, Catherine T. Vu

Affiliation: UC Davis, Department of Radiology, UC Davis Health

Abstract Preview: Purpose:
Accurate estimation of the Lung Shunt Fraction (LSF) is critical for yttrium-90 (90Y) radioembolization treatment planning to minimize risks of excessive lung irradiation due to arterio-ve...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...