Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun
Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute
Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...
Authors: Bryan Bednarz, Malick Bio Idrissou, Campbell Haasch, Reinier Hernandez
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, University of Wisconsin - Madison
Abstract Preview: Purpose: Quantitative optical imaging is a powerful tool in murine models for assessing tumor growth and metastatic spread using bioluminescence imaging (BLI) and for detecting radiopharmaceutical upt...
Authors: Zilei Fu, Yi Guo, Wanli Huo, Hongdong Liu, Laishui Lyu, Zhao Peng, Yaping Qi, Senting Wang
Affiliation: Department of Radiotherapy, cancer center, The First Affiliated Hospital of Fujian Medical University, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Division of lonizing Radiation Metrology, National Institute of Metrology, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, China Jiliang University, Department of Oncology, Xiangya Hospital, Central South University
Abstract Preview: Purpose: Medical image boundaries are commonly characterized by smooth gray-level transitions, resulting in pixel-level segmentation errors near these blurred boundaries. To address this, we developed...
Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...
Authors: Denis Bergeron, Ryan P Fitzgerald, Ravneet Kaur, Rao Khan
Affiliation: John Hopkins University, NIST Radiation Physics Division, Howard University, National Institute of Standards and Technology
Abstract Preview: Purpose: There is growing interest in short-lived alpha-emitting radionuclides for cancer therapy due to their ability to selectively target and destroy cancer cells while sparing healthy tissue. Howe...
Authors: Wenhua Cao, Hadis Moazami Goudarzi, Madison Emily Grayson, Zongsheng Hu, Gino Lim, Steven Hsesheng Lin, Radhe Mohan
Affiliation: The University of Texas MD Anderson Cancer Center, Department of Industrial Engineering, University of Houston, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Proton Arc Therapy (PAT) offers significant potential in treating complex cancer cases by delivering a continuous radiation dose as the gantry rotates. This study aims to investigate the pote...
Authors: Justus Adamson, Wesley Andrew Cunningham, Caleb Logan Smith
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: Radiation induced bowel toxicity is a persistent issue for abdominal Stereotactic Body Radiation Therapy (SBRT). Remote magnetic navigation systems (RMNS) have been developed for use in magne...
Authors: David Alejandro Collazos Burbano, Antonio Adilton Oliveira Carneiro, Paul L. Carson, Jose Eduardo Freire, Theo Zeferino Pavan, Joao Henrique Uliana, Nicholas Zufelato
Affiliation: University of São Paulo, University of Michigan, University of Sao Paulo
Abstract Preview: Purpose: Develop a theranostic platform that integrates magnetic hyperthermia (MH), ultrasound, and magnetic nanoparticles (MNPs) to improve diagnosis, treatment, and monitoring of hyperthermia proced...
Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng
Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University
Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...
Authors: Yunfei Dong, Dongyang Guo, Zhenyu Yang, Fang-Fang Yin, Zeyu Zhang
Affiliation: Duke University, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
To develop a Biomechanically Guided Deep Learning Registration Network (BG-DRNet) that improves both accuracy and physiological plausibility in liver image registration. While cone-beam CT...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Elsa Bifano Pimenta
Affiliation: University of São Paulo (USP), Institute of Physics
Abstract Preview: Purpose: This study evaluates the similarity between the linear attenuation coefficients of soft tissues and 3D printing materials in diagnostic imaging range using the Euclidean distance approach.
Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang
Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine
Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...
Authors: Meghan Lubner, Krista McClure, Aria M. Salyapongse, Timothy P. Szczykutowicz, Giuseppe Toia, Ming Yan, Zhye Yin, Meghan Yue
Affiliation: GE HealthCare, Departments of Radiology and Medical Physics, University Wisconsin-Madison, GE Healthcare, University of Wisconsin-Madison, UW-Madison, University of Wisconsin Madison, Department of Radiology
Abstract Preview: Purpose: To evaluate virtual unenhanced (VUE) and true unenhanced (TUE) human subject images on a prototype deep silicon photon-counting detector (PCD) CT with prototype algorithms.
Methods: 5 subj...
Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...
Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...
Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed
Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...
Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav
Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)
Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...
Authors: Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert
Affiliation: Dartmouth College
Abstract Preview: Purpose: The rigid needle-like EPR sensor, OxyTrack, was developed to provide minimally invasive, reliable, and quantitative measurements of oxygen distribution (pO2) in deep tissues. EPR oximetry's c...
Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu
Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou
Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...
Authors: Yi-Fang Wang, Yading Yuan
Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...
Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder
Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...
Authors: Enhui Chang, Yunfei Dong, Yifei Hao, Chengliang Jin, Shengsheng Lai, Yi Long, Mengni Wu, Yulu Wu, Ruimeng Yang, Zhenyu Yang, Yue Yuan, Lei Zhang, Wanli Zhang, Yaogong Zhang
Affiliation: Duke Kunshan University, Department of Radiology, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: Macrotrabecular-Massive Hepatocellular Carcinoma (MTM-HCC) is one type of liver cancer showed minimum image signature for accurate non-invasive diagnosis. This study aims to develop and evalu...
Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler
Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...
Authors: Michalis Aristophanous, Laura I. Cervino, Maria F. Chan, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Y Lee, Xiang Li, Seng Boh Gary Lim, Usman Mahmood, Jean M. Moran, Jason Ocana
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To determine the limits of iodine concentration detection (LOD) and quantification (LOQ) in dual-energy computed tomography using a 3D printed phantom while considering different background, ...
Authors: Liang Cui, Xingyu Lu, Hang Shang, LingHong Zhou
Affiliation: Southern Medical University
Abstract Preview: Purpose: This study examines how varying dose rates of radiotherapy impact normal tissues outside the target area and analyzes the protective effects and regulatory mechanisms of ultra-high dose rate ...
Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink
Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems
Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...
Authors: Martin Frank, Oliver Jäkel, Niklas Wahl
Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Karlsruhe Institute of Technology (KIT)
Abstract Preview: Purpose: Machine learning (ML) models on normal tissue complication and tumor control probability ((N)TCP) exploiting e.g. dosiomic and radiomic features are playing an increasingly important role in ...
Authors: Wesley E. Bolch, Emily L. Marshall, Dhanashree Rajderkar, Wyatt Smither
Affiliation: University of Florida
Abstract Preview: Purpose: To determine the accuracy of TotalSegmentator, an AI-based automatic segmentation toolkit, on pediatric CT scans as the original software was trained on adult image datasets with a mean patie...
Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq
Affiliation: Khalifa University
Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...
Authors: David Alcorta, Joseph Farina, Timothy Haystead, Yiping He, Philip Hughes, David Loiselle, Marybeth Nedrud, Victoria J. P. Radosova, Jianpeng Yu
Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Duke University School of Medicine, Duke Cancer Institute
Abstract Preview: Purpose: Targeted radiopharmaceuticals have become of widespread interest in the scientific community given their ability to detect and treat metastatic disease. We aim to validate the use of novel ch...
Authors: Richard Bakst, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Minglei Kang, Nancy Y Lee, Haibo Lin, Hang Qi, Charles B. Simone, Pingfang Tsai, Milo Vermeulen, Shouyi Wei, Xiaodong Wu, Lee Xu, Irini Yacoub, Xingyi Zhao, Ajay Zheng
Affiliation: University of Miami, Peking University, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, icahn school of medicine at mount sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose:
Three-dimensional lattice radiation therapy (3D-LRT) effectively achieves local tumor control with limited morbidity. Pencil beam scanning (PBS) proton therapy provides precise dose confor...
Authors: Rico Castillo, Katherine Gonzalez, Casey C. Heirman, Kyle J. Lafata, Xiang Li, Yvonne M Mowery, Yvonne M Mowery, Allison Pittman, Ashlyn G. Rickard, Breylon Riley
Affiliation: Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh
Abstract Preview: Purpose: To evaluate the relationships between quantitative imaging biomarkers and chemoradiation resistance in head and neck squamous cell carcinoma (HNSCC) using preclinical mouse models.
Met...
Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl
Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)
Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...
Authors: Trevor McKeown, Deshan Yang, Zhendong Zhang
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose: Accurate delineation of liver blood vascular structures is crucial for planning and executing therapeutic interventions in liver-related medical procedures. However, current auto-segmentation...
Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University
Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...
Authors: Chingyun Cheng, Ben Durkee, Carri K. Glide-Hurst, Minglei Kang, Haibo Lin, Bhudatt R. Paliwal, Charles B. Simone, Zhizhen Wei, Tengda Zhang, Xingyi Zhao
Affiliation: University of Wisconsin, Department of Mechanical Engineering, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Transmission Beam (TB), Single-Energy Bragg Peak (SEBP), and Single-Energy Spread-Out Bragg Peak (SESOBP) are primary proton conformal FLASH techniques. However, each comes with significant l...
Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni
Affiliation: Mercy Hospital Springfield
Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...
Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...