Search Submissions 🔎

Results for "lower eclipse": 19 found

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Deep Learning-Based Dose Distribution Prediction for Automation of Treatment Planning

Authors: Yaspal Badyal, Rabten Datsang, Tianjun Ma, William Song

Affiliation: MVision AI, Virginia Commonwealth University

Abstract Preview: Purpose: Deep learning (DL)-based dose distribution predictions for prostate cancer show significant potential for OAR sparing compared to manually optimized treatment plans. We aim to generate clinic...

Development of a Template-Based Planning Workflow for Offline Adaptive Head and Neck Cancer Using Ethos 2.0

Authors: Kaelyn Becker, Xenia Ray

Affiliation: University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: Ethos 2.0 with HyperSight (Varian Medical Systems) imaging enables nearly fully automated offline adaptive radiotherapy including automated deformation of targets and recalculation on the Hou...

Dosimetric Assessment of Spatially Fractionated Radiation Therapy on Prostate Cancer Cases: Our Experience in Nsia-Luth Cancer Center, Lagos

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Sylvester Entonu, Muhammad Habeebu, Adedayo O. Joseph, Oluwaseyi Oderinde, Oluwadara Ojediran, Margaret Dideolu Taiwo

Affiliation: University of Ibadan, University of Lagos, Missouri University of Science and Technology, Purdue University, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre

Abstract Preview: Purpose:
Spatially Fractionated Radiation Therapy (SFRT) is an advanced radiotherapy technique designed to deliver highly heterogeneous radiation doses, aiming to optimize tumor control while minim...

Dosimetric Comparison of 6X and 10X Flattening Filter-Free Photon Beams on a Truebeam Linac Using the Eclipse TPS

Authors: Carlos E. Cardenas, Udbhav S. Ram, Marcin Wierzbicki

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham, Juravinski Cancer Centre

Abstract Preview: Purpose:
This study aims to systematically evaluate the dosimetric properties and delivery efficiency of 6X-FFF and 10X-FFF beams for lung SBRT on the Varian TrueBeam STx using the Eclipse TPS 16.1...

Dosimetric Comparison of Lattice and 3D Grid VMAT Planning for Spatially Fractionated Radiotherapy

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to conduct a dosimetric comparison between lattice radiotherapy (LRT) and 3D grid treatment planning techniques, focusing on their differences in delivering three-dimensional ...

Dosimetric Variations Induced By Inaccurate Collimator Angles in Single-Isocenter SRS Plan for Multi-Lesion Brain Metastases

Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue

Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...

Evaluation of Hybrid Dynamic Conformal Arc Planning for SRS and SBRT Treatment

Authors: Pat Esposito, Ashley Klein, Carmine Verna, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To evaluate dosimetric parameters and treatment delivery efficiency between volumetric modulated arc therapy (VMAT) and hybrid dynamic conformal arc (HDCA) on SRS and SBRT planning through st...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexion™ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXion® X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Feasibility Study of Ethos Artificial-Intelligence Online Adaptive Prostate SBRT

Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez

Affiliation: Hospital General Universitario Santa Lucia

Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Impact of Arc Number Variation on VMAT Lattice Radiotherapy Plans

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to evaluate the effects of varying the number of arcs on treatment plans created using Volumetric Modulated Arc Therapy (VMAT) for Lattice radiotherapy (LRT).
Methods: Thre...

Personalized and Automated Head & Neck Radiotherapy Planning with AI-Guided Optimization

Authors: Michael Bowers, Patrik Brodin, Madhur Garg, Rafi Kabarriti, William P. Martin, Todd R. McNutt, Julie Shade, Wolfgang A. Tomé, Christian Velten

Affiliation: Johns Hopkins University, Oncospace, Inc., Montefiore Medical Center

Abstract Preview: Purpose: Development of an automated planning tool utilizing AI generated patient-specific dose-volume histogram predictions for rapid H&N plan generation.
Methods: Planning best-practices were dev...

Retrospective Study Using Avi Planner for Head and Neck Cancer Cases: Our Experience at Nsia-Luth Cancer Center, South - West Nigeria

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba

Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center

Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...

The Role of 3D Vane MRI in Accurate Phase Matching with 4D-CT for Motion Representation in Liver Cancer Radiotherapy

Authors: Jiayun Chen, Shengqi Chen, Junchao Li, Fei Liu, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, Tongji Medical College, Huazhong University of Science & Technology, School of Electronic Engineering, Beijing University of Posts and Telecommunications, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To assess if 3D Vane MRI can accurately depict the motion of the target volume and OARs.
Methods: This retrospective study included 54 liver cancer patients who underwent both 3D Vane MRI ...

Using Radiotherapy Dose Accumulation Routine (RADAR) for Deformable Offline Adaptive Head and Neck Dose Accumulation

Authors: Shira Abraham, Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Phillip G. Lichtenwalner, Chuan Zeng, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
We have developed a tool that uses deformable image registrations to perform deformable dose accumulation. In this work we evaluate use of this tool for adaptive head and neck dose accumul...