Search Submissions 🔎

Results for "measured calculated": 135 found

A Comparative Analysis of the Dosimetric, Alignment, and Setup Efficiency in Left Breast Cancer Radiotherapy Treated with Dibh Using ABC and Sgrt

Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin

Affiliation: Johns Hopkins University

Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...

A Comparative Evaluation of CT Global Noise Calculation Methods for Upcoming CMS Image Quality Measure

Authors: Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The recently introduced CMS regulation on CT dose and image quality mandates the use of global noise as the metric for image quality assessment. The regulation cites two methods for calculati...

A Comparison of Segment-By-Segment Versus Cumulative Signal Evaluation for Patient-Specific QA Using the Integral Quality Monitor

Authors: John J. DeMarco, Farideh Pak, Olivia Grahm C Valadie

Affiliation: Cedars Sinai, Cedars-Sinai, Cedars-Sinai Medical Center

Abstract Preview: Purpose: To investigate the performance of the Integral Quality Monitor (IQM) device for patient-specific QA, focusing on segment-by-segment signal evaluation compared to cumulative signal evaluation....

A Deep Learning Approach to the Prediction of Gamma Passing Rates in VMAT Radiotherapy Plans for Adaptive Treatment.

Authors: Jenghwa Chang, Kuan Huang, Lyu Huang, Jason Lima, Jian Liu, Farzin Motamedi

Affiliation: Northwell, Department of Computer Science and Technology, Kean University, Physics and Astronomy, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Title: A Deep Learning Approach to the Prediction of Gamma Passing Rates in VMAT Radiotherapy Plans for Adaptive Treatment.
Purpose: This study aims to develop a deep learning algorithm to predict ...

A Dosimeter Independent Method for Measuring Dose from Contrast Enhanced Mammography Exposure.

Authors: Mitya M. Barreto, Nichole A. Harris

Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center

Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...

A GPU Accelerated Monte Carlo Dose Engine for Small Animal Proton Radiotherapy

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Topological Technique to Unify Image Texture and Morphology to Enhance Radiomic Feature Representations

Authors: David Brizel, Kyle J. Lafata, Jian-Guo Liu, Yvonne M Mowery, Yvonne M Mowery, William Paul Segars, Jack B Stevens

Affiliation: Department of Physics, Duke University, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh

Abstract Preview: Purpose: To develop a technique to quantify tumor topology using a unifying mathematical framework that integrates texture and morphology and to evaluate its feasibility as a prognostic biomarker for ...

Absolute Measurement of HDR Ir-192 Air-Kerma Strength Using an Exradin A3 Known-Volume Ionization Chamber

Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Advancing Cardiac Sparing with Upright Patient Geometry and Deep Learning

Authors: Shae Gans, Carri K. Glide-Hurst, Mark Pankuch, Chase Ruff, Niek Schreuder, Nicholas R. Summerfield, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center, Leo Cancer Care

Abstract Preview: Purpose: Novel upright patient positioners coupled with diagnostic-quality vertical CT at treatment isocenter introduce a significant opportunity for improved image-guided particle therapy. Treating p...

An Adjustable Wool Fiber Phantom for Investigating the Detection of Anisotropy with Ultrasound Speckle Statistics

Authors: Alexandra Christensen, Timothy J. Hall, Ivan M. Rosado-Mendez

Affiliation: University of Wisconsin, Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: Quantitative ultrasound techniques based on the statistical analysis of speckle are currently being deployed commercially and clinically as sources of biomarkers associated with tissue micros...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Analysis of Inter-Organ Noise Variability for Clinical CT Images across 3133 Image Series

Authors: Lavsen Dahal, Francesco Ria, Ehsan Samei, Justin B. Solomon, Liesbeth Vancoillie, Yakun Zhang

Affiliation: Duke University, Carilion Clinic, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Clinical diagnostic task-based optimization of CT procedures require precise and organ-specific assessments. This study investigates inter-organ noise variability to highlight the limitations...

Applicability of Online Dose Measurement in Trilogy Linear Accelerators: Using Target Current Pulse Counting Method

Authors: Daming LI, Jinsen Xie, Zhe Zhang

Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China

Abstract Preview: Purpose:
This study aims to investigate the feasibility of online dose measurement of the Trilogy linear accelerator output based on target current pulse signals.
Methods:
A data acquisition ...

Application of a Conditional Diffusion Model to Improve Real-Time MR Imaging in Online Adaptive MR-Guided Radiotherapy

Authors: Hideaki Hirashima, Haruo Inokuchi, Nobutaka Mukumoto, Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao, Keiko Shibuya, Linna Zhang

Affiliation: Kyoto University, Osaka Metropolitan University

Abstract Preview: Purpose:
To transform the quality of 2D cine MR images acquired during online adaptive MR-guided radiotherapy (OA-MRgRT) by utilizing a conditional diffusion model to achieve image quality comparab...

Artificial Intelligence Based Auto-Contouring for Organs at Risk in Head and Neck

Authors: Mylinh Dang, Laila A Gharzai, Xinlei Mi, Poonam Yadav

Affiliation: Northwestern Feinberg School of Medicine, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine

Abstract Preview: Purpose: Delineation of organs at risk (OAR) in the head/neck region requires substantial physician time. Many artificial intelligence (AI) based auto-contouring software are commercially available. T...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Assessing the Impact of Weighting Dose Volume Histograms By Variable Relative Biological Effectiveness for Radiation-Induced Lymphopenia Risk Prediction

Authors: Yan Chu, Madison Emily Grayson, Radhe Mohan, Pablo P. Yepes

Affiliation: UT Health Science Center at Houston, Rice University, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Radiation-induced lymphopenia (RIL) is a common adverse effect of radiation therapy, negatively impacting overall survival and anti-PD1 immunotherapy efficacy. Our lab previously developed a ...

Assessment of Alpha-Fetoprotein As a Prognostic Factor of Overall Survival for HCC Patients Undergoing 90Y-Glass Trans-Arterial Radioembolization

Authors: Srinivas Cheenu Kappadath, James Long, Armeen Mahvash, Anna Marks, Ajalaya Teyateeti

Affiliation: Mahidol University, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Alpha-fetoprotein (AFP) has been implicated as prognostic factor of overall survival (OS) for hepatocellular carcinoma (HCC). We present a statistical approach to determine optimal AFP-cut...

Assessment of Material Discrimination Slopes in Dual Energy CT Imaging

Authors: Izabella L. Barreto, Aroon Pressram

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Our clinical dual energy CT (DECT) head protocol reconstructs iodine-suppressed virtual non-contrast (VNC) images using the vendor-recommended slope for material discrimination. However, this...

Assessment of Off-Target Dose for Curative Treatment of Pregnant Head and Neck Cancer Case: A Monte-Carlo Study

Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park

Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital

Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...

Assessment of Plan Quality Metrics for Iroc Houston SRS Phantom Performance Evaluation

Authors: Derek Matthew Garcia, Mallory Glenn, Stephen F. Kry, Ruitao Lin, Dennis S. Mackin, Tucker J. Netherton

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas’ MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: This study aims to investigate the feasibility of implementing clinically relevant quality metrics for evaluating IROC SRS phantom plans, including conformity index (CI) and homogeneity index...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Automated Review of Radiation Treatment Delivery Reports Using Openai

Authors: Ramesh Boggula, Nikhil Jordan Shad

Affiliation: Wayne State University

Abstract Preview: Purpose: To evaluate the effectiveness of OpenAI in reviewing large volumes of radiation delivery reports from Mobius3D/FX. The goal was to assess whether automating this process could identify potent...

Automatic Specific Absorption Rate (SAR) Prediction for Hyperthermia Treatment Planning (HTP) Using Deep Learning Method

Authors: Yankun Lang, Lei Ren, Dario B. Rodrigues

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose:
HTP of microwave (MW) phased-array systems determine MW antenna settings to maximize energy absorption (SAR in W/kg) in tumor. Conventional HTP algorithms calculate SAR based on electromag...

BEST IN PHYSICS IMAGING: Population-Based Cardio-Respiratory Motion Model to Simulate 4D CT Angiography and 2D+t Fluoroscopy for Percutaneous Coronary Intervention

Authors: Debarghya China, Junghoon Lee, Ali Uneri

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins Univ

Abstract Preview: Purpose: This study aims to develop a population-based cardio-respiratory motion model and apply it to patient-specific 3D CTA to simulate 4D CTA and 2D+t fluoroscopy sequences. The developed motion m...

BEST IN PHYSICS RADIOPHARMACEUTICALS, THERANOSTICS AND NUCLEAR MEDICINE: Characterization and Dose Rate Calibration of a Semiconductor-Based Radiation Imaging Survey Meter

Authors: Steven Brown, Mike Hopkins, Jerimy C. Polf, Scott Sawyer, Benjamin L. Viglianti

Affiliation: H3D, inc, University of Michigan, M3D, Inc, M3D Imaging

Abstract Preview: Purpose: We characterized the sensitivity, energy dependence, and calibrated dose rate for a radiation imaging survey meter (RAVIN Cam; M3d inc., Ann Arbor MI) based on cadmium zinc telluride (CZT) cr...

CBCT Dose Measurement for Common Protocols on Elekta Versahd and Varian Truebeam

Authors: Yingxuan Chen, Jun Li, Alexis N. Webb

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...

CBCT-Based Synthetic CT Imaging for Proton and Photon Dose Monitoring and Adaption in Supine Breast Radiotherapy

Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang

Affiliation: UF Health Proton Therapy Institute, University of Florida

Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...

Characterization and Validation of Cerenkov Radiation Extraction Methods from a Plastic Scintillation Detector in 0.35T MR-Linac Environments

Authors: Mateb Ali Alghamwa, Haya Aljuaid, Siyong Kim, Tianjun Ma, William Song

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: The integration of Plastic Scintillation Detectors (PSDs) into 0.35T MR-Linac systems represents a significant advancement in radiotherapy, offering substantial benefits due to their tissue-e...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Clinical Validation of a Deep-Learning Segmentation Tool for Head and Neck Cancer Patients and Thoracic and Abdominal Cancer Patients

Authors: Haijian Chen, Katja M. Langen, William Andrew LePain, Claire Tran, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Georgia Institute of Technology

Abstract Preview: Purpose: To validate the performance of a commercial deep-learning segmentation (DLS) tool for head and neck cancer (HNC) and thoracic and abdominal cancer (TAC) by comparing it to manual segmentation...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning and Validation of Monaco Proton Treatment Planning System on a Compact Proton Therapy System

Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Commissioning, Validation and Pilot Study of New Rpld System for Dosimetry Audits in Bulgaria

Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov

Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital

Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Decreasing the Dependence of CT Number on the Position in the Field-of-View Using Photon Counting Detector CT

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...

Deep Learning-Based Eye Monitoring and Tracking System for Ocular Proton Therapy in a Regular Gantry Room

Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai

Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...

Deep Learning-Based Metric Vs Global Noise for CT Image Quality Assessment

Authors: Gary Y. Ge, Abdullah-Al-Zubaer Imran, Kazi Ramisa Rifa, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: With renewed attention on CT radiation dose management following CMS approval of new dose measures, establishing image quality–based target doses for every protocol has become essential. Whil...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Development of Sphere Phantoms for Quantitative Evaluation of Computed Tomography Systems Resolution

Authors: Hyo-Min Cho, Changwoo Lee

Affiliation: Korea Research Institute of Standards and Science

Abstract Preview: Purpose: We develop sphere phantoms to assess spatial resolution of computed tomography (CT) systems and validate its usability using table-top X-ray experiment systems.
Methods: We manufactured sp...

Development of Treatment Planning System for Carbon Ion Radiotherapy in Yonsei Cancer Center

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...

Development of a Computational Immunohistochemical Stained Tissue Analysis of Intracellular Flash Induced Radiochemical Oxygen Depletion

Authors: Najah Curtis, Michele M. Kim, Cameron Koch, Ioannis I Verginadis, Rodney D. Wiersma, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: FLASH has been shown to have increased normal tissue sparing compared to standard dose rate radiation and, separately, has been shown to rapidly consume oxygen intercellularly in vivo through...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Development of an MRI Guided Precision Small Animal Radiotherapy System

Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...

Direct in-Vivo Real-Time Singlet Oxygen Detection in Photofrin-Mediated Photodynamic Therapy (PDT) Using Multispectral Singlet Oxygen Dosimetry (MSOLD)

Authors: Theresa Busch, Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Brian C. Wilson, Weibing Yang, Timothy C. Zhu

Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania

Abstract Preview: Purpose: Direct detection of singlet-state oxygen (ÂčO₂) is crucial for advancing type II photodynamic therapy (PDT), but its short lifetime makes in vivo measurement highly challenging. Although Photo...

Does the Method Matter? How in Hominum, In Vivo, in silico, and in Phantasma Measures Compare and Contrast Is Assessing the Utility of Photon Counting CT?

Authors: Ehsan Abadi, Njood Alsaihati, Steven T. Bache, Mridul Bhattarai, Cindy Marie McCabe, Francesco Ria, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Duke University Health System, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: To compare and contrast alternative methods including reader (in hominum), phantom (in phantasma), in vivo, and in silico methods deployed to assess the performance of photon counting (PCCT) ...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Dosimetric Characteristics of a Commercially Available Platinum Cured Silicone Rubber Material As a Custom Bolus Option

Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon

Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center

Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Ensuring Consistency in Digital Pathology: Medical Physics Approaches to Comparison of Scanner Contrast and Chromaticity

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Medical physicists have traditionally supported radiation-based medicine, but their expertise can translate to other image-based fields including pathology. As pathology transitions to digita...

Equivalent Uniform Dose and Duodenal Toxicity Correlation in Pancreatic Cancer Irradiation

Authors: Samira Dabaghmanesh, Beth A. Erickson, William Hall, Jason Hirshberg, An Tai

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Treatment plan evaluation for minimizing duodenal toxicity often involves multiple dose-volume constraints that vary based on fractionation. The Equivalent Uniform Dose (EUD) has emerged as a...

Evaluating Longitudinal Amyloid Burden Related to Alzheimer’s Disease When Transitioning between PET ÎČ-Amyloid Radiotracers

Authors: Brecca Bettcher, Tobey J Betthauser, Bradley T Christian, Sterling Johnson, Lisette LeMerise, Max McLachlan, Andrew McVea, Dhanabalan Murali, Ali Pirasteh, Matthew Zammit

Affiliation: University of Wisconsin-Madison School of Medicine and Public Health and Waisman Center

Abstract Preview: Purpose: The radiotracer [18F]NAV4694 is a desirable alternative to [11C]PiB for measuring amyloid neuropathology related to Alzheimer’s disease (AD), possessing similar imaging characteristics and fa...

Evaluating Variability in Luminance Measurements Among Calibrated Light Meters for Mammography Review Workstation Surveys

Authors: Weiyuan Wang

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose:
This study investigates the variability between popular light meters by measuring mammography review workstation monitors using three calibrated light meters.
Methods:
Three calibrat...

Evaluating the Aktina Isopoint System for Quality Assurance in Linear Accelerators

Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...

Evaluating the Impact of an Average Versus Machine-Specific Dosimetric Leaf Gap on Dose Calculation

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...

Evaluating the Interchangeability of Two Similar but Not Beam-Matched Varian Truebeam Linear Accelerators in the Delivery of Patient-Specific Quality Assurance

Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...

Evaluation of Charge Collection Performance in the A30 Prototype Parallel Plate Ion Chamber in Ultra-High Dose Rate Beam

Authors: Mervat A. Alharbi, Wesley S. Culberson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Medical Physics Department, School of medicine and Public Health, University of Wisconsin-Madison

Abstract Preview: Purpose: The charge collection using ionization chambers is challenging at ultra-high dose rates (UHDR) due to the high ion recombination The Exradin A30 prototype parallel-plate ion chamber manufactu...

Evaluation of Color Display Performance of Pathology Relevant Colors Using the Macbeth Colorchecker

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Display image accuracy is critical for digital diagnostic fields, such as radiology and digital pathology. While the AAPM TG-18 test patterns are established for grayscale radiology monitor Q...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

Evaluation of Dose-Rate Metrics in Intensity Modulated Proton Therapy for Prostate Cancer Treatments

Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University

Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...

Evaluation of Four Different Dose Calculation Algorithms for Commissioning of a New Tyoe of Scanned Proton Therapy System

Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga

Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University

Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Evaluation of the Reflexion X1 As a Standalone PET/CT Simulator for Treatment Planning and Treatment Adaptation

Authors: Chunhui Han, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the RefleXion X1 imaging system as a standalone positron emission tomography and computed tomography (PET/CT) simulator for radiotherapy treatment planning and adaptive re-plannin...

Fast 3D Scintillation Dosimetry Using Single View Deep Learning Reconstruction

Authors: Louis Archambault, Nicolas Drouin, Alexis Horik, Simon Thibault

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de Physique, de Génie Physique et D'optique, et Centre d'optique, photonique et laser, Université Laval

Abstract Preview: Purpose: To develop a novel type of real-time 3D dosimeter for the quality assurance of linear accelerators used in external beam radiotherapy.
Methods: An experimental setup was constructed using ...

Feasibility Analysis of Applying a Remote Magnetic Navigation System for Bowel Sparing during SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Chang-Sei Kim, Yeongoh Ko

Affiliation: Duke University, Chonnam National University, Duke University Medical Center

Abstract Preview: Purpose: Toxicity to bowel remains a challenge for radiotherapy, particularly for abdominal SBRT . We propose a noninvasive method to reposition bowel using a remote magnetic navigation system (RMNS) ...

Feasibility of Using a Dynamic-Platform with High-Resolution Patient-Specific QA Device for Periodic and Patient-Specific-QA in Respiratory-Gated Radiotherapy Lung SBRT Treatment

Authors: Tae Kyu Lee

Affiliation: Allina Health

Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...

Feasibility of Zap-X Beam Quality Assurance Using Cherenkov Radiation

Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao

Affiliation: University of Miami

Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

First Phantom Testing of Biology-Guided Radiotherapy for Sequential Integrated Boost Radiotherapy

Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...

GPU-Accelerated Beamlet and Full Dose Calculations for Efficient Radiation Therapy Planning

Authors: Girish Bal, Jan Kralj, Ayan Mitra, PhD, Ling Shao, Matjaz Subic, Yevgen Voronenko

Affiliation: RefleXion Medical, Cosylab

Abstract Preview: Purpose: This work enhances the efficiency of radiation therapy treatment planning by optimizing the beamlet dose matrix and full patient dose computations using GPU acceleration. The Collapsed-Cone C...

HDR End-to-End Testing of Horizontal Leipzig Skin Applicators with Ir-192 Calibrated Oslds

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell

Affiliation: Mount Sinai Beth Israel

Abstract Preview: Purpose: Commissioning of Flexitron HDR horizontal Leipzig applicators typically includes indirect or direct output verification, using a well chamber specific Revised Correspondence Factor (CFrev) or...

Imaging of Mn Washout in the Individual Welder Brain after Wearing Powered Air-Purifying Respirators (PAPRs)

Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park

Affiliation: Purdue University

Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Impact of Tumor-to-Normal Ratio and Glass Microsphere Particle Density on Local Progression-Free Survival Following Lobar Yttrium-90 Radioembolization

Authors: Jason Chiang, Magnus Dahlbom, Veronica Hankil, Xinyi Li, Catherine (Caffi) Meyer, Kyung Hyun Sung

Affiliation: UCLA, University of California, Los Angeles

Abstract Preview: Purpose:
Yttrium-90 (90Y) radioembolization is a well-established therapy for large or multifocal liver tumors. Accurate dosimetry is critical but remains challenging, as low particle density risks...

Implementing a Physics Effort Unit Model to Quantify and Optimize Therapeutic Medical Physicist Productivity

Authors: Michael J. Price, Adam C. Riegel

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: We present a robust and scalable model to quantify the diverse responsibilities of therapeutic medical physicists (tMPs) and assess individual and team productivity comprehensively.
Method...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Improving Stroke Treatment Using Magnetic Nanoparticle Sensors to Monitor Mechanical Thrombectomy

Authors: Clifford Eskey, Scott Gordon-Wylie, Scott Gordon-Wylie, Dhrubo Jyoti, Daniel Reeves, John B. Weaver

Affiliation: Flow Aluminum, Dartmouth College, Fred Hutch Cancer Center, University of Washington, Dartmouth-Health

Abstract Preview: Purpose: Mechanical thrombectomy (MT) is the preferred treatment for ischemic stroke from large vessel occlusion. The thrombus or clot is extracted from the vessel via a catheter using a stent retriev...

In Vivo Dosimetry for Cied Management – Is It Really Needed?

Authors: Anthony J. Doemer, Aharon Feldman, Stephen J. Gardner, Brett M. Miller, Benjamin Movsas, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia

Affiliation: Henry Ford Health

Abstract Preview: Purpose: To evaluate the efficacy of calculation-only approach for CIED risk-level assessment.
Methods: A total of 86 patients were included in this retrospective analysis. For each patient, in viv...

Inconsistencies in Methods for CMS Size-Adjusted Dose Measure

Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The upcoming CMS regulation, titled “Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults”, employs two measures, size-adjusted DLP (SAD) and...

Investigating Interstitial Fluid Pressure and Hydraulic Conductivity By Examining the Biophysical Properties of Drug Transport Using Cross Voxel Exchange Model and Dynamic Contrast Enhanced MRI

Authors: Catherine Coolens, Janny Yeyoung Kim, Michael Milosevic, Noha Sinno

Affiliation: Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: In solid tumors, Interstitial fluid pressure (IFP) acts as a barrier to molecular transport to the tumor center and serves as a predictor of cancer patients’ treatment responsiveness. The nov...

Investigating the Use of a DWI Phantom for Routine QA of an MR-Linac at Room Temperature

Authors: Nicholas Carlson, Joel J. St-Aubin

Affiliation: University of Iowa Hospitals and Clinics, University of Iowa

Abstract Preview: Purpose: To establish baselines metrics and determine longitudinal accuracy and reproducibility of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) values for a 1.5T Elekta Un...

Investigation of Flash Proton Irradiation Induced DNA Double Strand Breaks Under Different Free Radical Scavenger Environments

Authors: Hansong Bai, Peter Jermain, Xun Jia, Heng Li, Devin Miles, Daniel Sforza, Michael H. Shang, Daniel Robert Strauss, Keith Unger, Lingshu Yin

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, MedStar Georgetown University Hospital, Johns Hopkins University, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose: To investigate DNA Double Strand Break (DSB) induced by FLASH proton irradiation in a repair-free plasmid DNA model under different free radical scavenging conditions in plateau and Bragg pea...

Ir-192 Percentage Depth Ionization of PLA and Ballistic Gelatin Compared to Water

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell

Affiliation: Northwell, Mount Sinai Beth Israel

Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...

Learning from Failures – Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Leveraging Photon Counting Detector CT and Advance Reconstructions to Improve the Accuracy of Vessel Tracing in Prostate Artery Embolization

Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

MR-Based Functional Liver Imaging and Dosimetry to Predict Albi Change Post-SBRT

Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei

Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan

Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...

Material Modulated 3D Printed Human-Tissue Simulant Phantoms for Radiation Therapy Modeling and Safety

Authors: Joseph A. Moore, Paul Rothweiler, Jussi K. Sillanpaa, Adhvaith Sridhar

Affiliation: University of Minnesota

Abstract Preview: Purpose: To investigate 3D printed human tissue simulant phantoms for use in radiation therapy and to quantify the mechanical and radiation properties of these phantoms.
Methods: We designed and 3D...

Maximum Conformity IMPT Planning with the Dynamic Collimation System

Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care

Abstract Preview: Purpose:
To perform end-to-end treatment planning and delivery verification of energy-specific collimated treatments optimized to achieve the maximum obtainable high-dose conformity using the dynam...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Moving Away from Measuring Everything - Implementing 3D Recalculation in a Large Networked Radiotherapy Institution to Replace Routine IMRT / VMAT QA

Authors: Eujin Chan, Christopher Colyer, Leon F Dunn, Jonathan Dunning, Michael Grace, Onno Kamst, Alex Livingstone, Thulani Nyathi, Vladimir Sashin, Philip Satory, Hilmar Schachenmayr, Brindha Subramanian, Lindsay J. Tremethick, Luke Webb

Affiliation: GenesisCare

Abstract Preview: Purpose: The purpose of this work is to outline the methodology and results from the implementation of a 3D recalculation software to replace IMRT/VMAT PSQA measurement across a large, networked radio...

Novel Methods to Select Patients for Functional Avoidance Radiotherapy

Authors: Vikas Aragam, Edward Castillo, Richard Castillo, Yingxuan Chen, Yevgeniy Vinogradskiy, Lydia J. Wilson

Affiliation: Thomas Jefferson University, Emory University, University of Texas at Austin

Abstract Preview: Purpose: 4DCT-based ventilation imaging (4DCT-ventilation) has been innovatively applied in radiotherapy treatment planning to minimize doses to functional portions of the lung, known as functional av...

Optimizing Calibration Radioisotope and Activity for Dose Calibrator Linearity Testing in Radiopharmaceutical Therapy and Theranostic Facilities

Authors: Kimyli Lemieux, Xingyu Nie

Affiliation: University of Kentucky/UK HealthCare

Abstract Preview: Purpose: To optimize the selection of calibration radioisotope and its activity for dose calibrator (DC) linearity testing, adhering to ALARA (As Low As Reasonably Achievable) principles while conside...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-ChacĂłn, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Preclinical Assessment of 68ga-Dotatate As a Surrogate for 177lu-Dotatate Dose Distribution in Radionuclide Therapy

Authors: Payman Hejazi, Faraz Kalantari, Milad Peer-Firozjaei, Romina Pourhashem, Ehsan Tajikmansoury

Affiliation: Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Medical Physics, Semnan University of Medical Sciences, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose:
Pretreatment biodistribution imaging play a crucial role in optimizing tumors and organ absorbed doses estimation in radionuclide therapy. Surrogating radionuclides for more efficient trea...

Quantification of Global Dosimetry Audit Performance: Assessing the Sensitivity and Specificity of Dosimetry Audits to Establish Reciprocity Among Different International Clinical Trials Credentialing Organizations

Authors: Fre'Etta Brooks, Catharine H Clark, Patricia Diez, Peter B. Greer, Hideaki Hirashima, Rebecca M. Howell, Mohammad Hussein, Stephen F. Kry, Joerg Lehmann, Jessica Lye, Mitsuhiro Nakamura, Christopher L. Nelson, Rushil Patel, Christine Peterson, Julianne M. Pollard-Larkin

Affiliation: Kyoto University, The University of Texas MD Anderson Cancer Center, Radiotherapy Trials Quality Assurance Group, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Medical Physics & Biomedical Engineering, University College London, Metrology for Medical Physics, National Physical Laboratory, Austin Health, University of Washington Medical Center, University of Newcastle

Abstract Preview: Purpose: To assess the consistency of end-to-end dosimetry audits currently used by different international clinical trial QA organizations with the goal of harmonizing audits and reducing audit overl...

Quantification of Wet Towel As Bolus on Skin Dose for VMAT Partial Breast Irradiation

Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang

Affiliation: Cleveland Clinic

Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.

Methods: Two VMAT partial breast plans (3000 cGy in 5...

Quantitative Evaluation of Eclipse’s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...

Radiation Dose Variability and Predictability Versus PTV Volume and Anatomical Site

Authors: Lars Ewell, Russell J. Hamilton

Affiliation: Banner University Medical Group, Bannerhealth

Abstract Preview: Purpose: To estimate the variability and predictability of radiation dose as a function of the planning target volume (PTV) size and the anatomical sites of head & neck, brain and prostate.
Methods...

Secondary Neutron Dosimetry of Cieds Exposed to Neutron-Producing Photon Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...

Speckle Image-Based Point Spread Function Reconstruction in Clinical Diagnostic X-Ray Systems

Authors: Jonthomas Michael Box, Isaac B. Rutel

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: This study assesses the feasibility of using speckle images and a modified phase retrieval algorithm to reconstruct the point spread function (PSF) of a diagnostic x-ray system. While speckle...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...

The GYN Webapp: A Centralized Tool for Enhancing HDR Brachytherapy Treatment Quality and Clinical Outcomes

Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...

Towards Arbitrary Phantom Patient Specific IMRT QA on Reflexion X1

Authors: Andrew Groll, Ayan Mitra, PhD, Manoj Narayanan, Sanchit Sharma, Ray Yang, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: To develop a versatile QA tool enabling dose recalculation of a patient’s plan sinogram redeployed onto arbitrary replacement phantom geometry, and extract computed dose along detector planes...

Towards Higher Quality Breast Radiotherapy Treatments: A First Evaluation of the Newly Introduced Inframammary Fold Breast Wedgeℱ Device from Qlrad

Authors: Thomas Furno, Arjen Winkel, Ramtin Zakikhani

Affiliation: Genesis Care USA, QLRAD, SMH

Abstract Preview: Purpose: To quantify the dosimetric impact of the newly introduced “Inframammary Fold (IMF) Breast WedgeTM ” device by QLRAD inc. in the region of the inframammary fold during breast radiotherapy.
...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Treatment Planning System Modelling of a New Commercial Rotational Table

Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.

Methods: A commercial rotational table (CDR EquilibriumÂź) is r...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...

Uncertainty in Contralateral Breast Dose Reconstruction for Breast Cancer Radiotherapy Patients in the United States between 1990 and 2012

Authors: Amy Berrington de Gonzalez, David Borrego, Rochelle Curtis, Gretchen L Gierach, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Lene Veiga, Jacqueline Vo

Affiliation: University of Michigan, East Carolina University, Radiation Protection Division, Office of Radiation and Indoor Air, U.S. Environmental Protection Agency, National Cancer Institute, Institute of Cancer Research

Abstract Preview: Purpose: Radiotherapy is vital for treating breast cancer, but its long-term health effects remain a concern. Accurate dose reconstruction is crucial for evaluating risks in retrospective epidemiologi...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

Validating a Pre-Existing CT HU-to-Mass Density Curve for Direct Dose Calculation on High Quality Cbcts

Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray

Affiliation: University of California San Diego

Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...

Validation of Updated CT-to-SPR Calibration Method with Icrp-145 Data for Carbon-Ion Radiotherapy

Authors: Min Cheol Han, Soorim Han, Chan Hyeong Kim, Jin Sung Kim, Seok-Ho Lee, Gahee Son, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The stoichiometric calibration method proposed by Kanematsu et al. (2016) has been widely adopted for CT number to stopping-power ratio (SPR) conversion in carbon-ion radiotherapy. With the r...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...