Search Submissions 🔎

Results for "measurements uniform": 18 found

A Comparative Study of Hypersight and Truebeam Cone Beam Computed Tomography Image Quality

Authors: Sorour Hosseini, YuHuei Jessica Huang, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To evaluate image quality—including noise, contrast-to-noise ratio (CNR), uniformity, and low-contrast visibility (LCV)—on the HyperSight and TrueBeam cone-beam computed tomography (CBCT) pla...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

An Efficient, Low-Cost, and Accessible Film Dosimetry Scanning System

Authors: Parminder S. Basran, Wyatt Flanders, Skylar Sylvester

Affiliation: Cornell University

Abstract Preview: Purpose: To develop a reliable, efficient, and low-cost methodology for quantifying radiation doses using radiochromic film and a custom-built lightbox and to evaluate the system's performance compare...

Commissioning of a 3D-CRT Planning Software for a Machine with Only Flattening-Filter Free Energy

Authors: Michalis Aristophanous, Steven Blum, Laura I. Cervino, Antonio L. Damato, Karen Episcopia, Chi Huang, Shih-Chi Lin, Michelle K. Savacool

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Varian Ethos (Varian Medical Systems, Palo Alto, CA) is a 6 MV flattening-filter-free (FFF) only machine, posing a challenge in creating homogeneous dose distributions when using manual 3D-CR...

Dosimetric Validation and Algorithmic Limitations of Pencil Beam Scanning Proton Therapy for Thin Chest-Wall Treatments

Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng

Affiliation: New York Proton Center, Scarsdale High School

Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...

Dynamic 2.5D Surface Dosimetry Using Deformable Scintillator Array Imaging

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous, Roman Vasyltsiv, Rongxiao Zhang

Affiliation: Dartmouth Health, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri

Abstract Preview: Purpose: On-patient dosimeters assist in clinical decision-making by measuring surface dose, but single-point measurements cannot monitor area-wide distributions and are misleading in high-gradient re...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

First-Time Live Imaging of Radiopharmaceutical Administration with a Hybrid Compton Camera

Authors: Ramesh Boggula, Jay W. Burmeister

Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine

Abstract Preview: Purpose: This study evaluated the performance of a hybrid Compton camera for real-time imaging during the administration of Lu-177-based radiopharmaceuticals, including Pluvicto and Lutathera. The aim...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Ir-192 Percentage Depth Ionization of PLA and Ballistic Gelatin Compared to Water

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell

Affiliation: Northwell, Mount Sinai Beth Israel

Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Serial PET-CT Activity Concentration during Small Target Lung Tumor SBRT

Authors: Joseph Barbiere, Joseph Hanley, Brett Lewis, Jay Mistry, Alois M. Ndlovu, Roland Teboh

Affiliation: Hackensack University Medical Center, HUMC, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Quantitative PET-CT can evaluate clinical response to radiotherapy. For tumors less than approximately 3cm partial volume effects due to the poor PET resolution makes accurate measurement ...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Synthetic Spheres: Ultrasound Image Quality Assessment with a Uniform Phantom

Authors: Ted Lynch

Affiliation: Sun Nuclear, a Mirion Medical Company

Abstract Preview: Purpose: A novel ultrasound quality assurance method is presented that constructs “synthetic spheres” at arbitrary locations within the image frame by combining correlation length measurements from a ...

Total Body Irradiation Using Field-in-Field Treatment Planning Techniques

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Validation of a Pharmacokinetic Model for Dosimetry in Nuclear Medicine

Authors: Farhad Jafari, Brandon Hai Nguyen

Affiliation: Department of Radiation Oncology, University of Minnesota Medical School, Department of Radiology, University of Minnesota

Abstract Preview: Purpose: To validate a bottom-up approach to dosimetry in nuclear medicine.

Methods: A pharmacokinetic model is developed to represent the flow of activity between different compartments of the...