Search Submissions 🔎

Results for "mid position": 44 found

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

An Integrated Optimization Method for Joint Lattice Positioning and Dose Planning in Lattice Therapy

Authors: Hao Gao, Xue Hong, Harold Li, Yuting Lin, Jufri Setianegara, Xin Tong, Chao Wang, Weijie Zhang, Ya-Nan Zhu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Lattice radiotherapy (LATTICE) is a form of spatially fractionated radiation therapy (SFRT) designed to deliver high radiation doses to specific tumor regions (vertices) while sparing surroun...

CNN-Based Reconstruction for 3D Scintillation Dosimetry of Proton Pencil Beams

Authors: Sam Beddar, Jason Michael Holmes, Daniel G. Robertson, James J. Sohn, Ethan D. Stolen

Affiliation: Department of Radiation Oncology, Mayo Clinic, MD Anderson Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago

Abstract Preview: Purpose: Camera-based scintillation dosimetry incorporating large volumes have shown promise for fast and comprehensive evaluation of external beam treatment fields. While some efforts have been made ...

Computational Prototype Single-Channel Vaginal Cylinder with Integrated Filter to Address Dose Uniformity in High-Dose-Rate Brachytherapy for Endometrial Cancer

Authors: Brett Bocian, Patrick James Jensen, Luis Augusto Perles, Christopher J. Tien

Affiliation: Yale University School of Medicine, University of Miami, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Guidelines for dose prescriptions in endometrial cancer are based upon depth from the cylinder, traditionally 5 mm or 0 mm (i.e., surface). There are no current single-channel vaginal cylinde...

Daily Adaptive Treatment Planning with Radixact for Head and Neck Cancer: A Dosimetric Evaluation

Authors: Yong Chen, Christina Henson, Yuchen Qiu, Marti Roper

Affiliation: University of Oklahoma HSC, University of Oklahoma Health Sciences Center, University of Oklahoma, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Traditionally, Head and Neck cancer patients have one or two treatment replans through their treatment course, which fails to account for anatomical changes in position, weight loss, or tumor...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development and Clinical Validation of an Analytical Approach for 3D Positron Emitter Distribution Prediction in Carbon Ion Therapy

Authors: Julia Bauer, Tianxue Du, Katia Parodi, Marco Pinto, Thomas Tessonnier

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose:
Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing irradiation-induced PE...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Enhancement of Adaptive Collimation Precision on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate aperture collimation on a C-shape gantry-mounted proton accelerator. Mevion S250i Hyper scanning machine implemented aperture collimation utilizing adaptive aperture (AA). The AA ...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Time Delays in a Surface-Guided Radiotherapy-Based Gating System Using Exactrac Dynamic and Truebeam Linear Accelerator

Authors: Hiroki Katayama, Hiroki Kawasaki, Motonori Kitaoka, Yosuke Takahashi, Takashi Tanii, Masato Tsuzuki

Affiliation: Kagawa University Hospital

Abstract Preview: Purpose:
Surface-guided radiotherapy (SGRT) with ExacTrac Dynamic (ETD) allows motion tracking and beam gating during treatment delivery. Accurate evaluation of beam-on and beam-off delays is essen...

Evaluation of an Offline Adaptive CBCT Planning Workflow for Halcyon with Hypersight

Authors: Michelle Alonso-Basanta, Joshua Bryer, Lei Dong, Barbara Garcia, Elissa Khoudary, Brandon M. Koger, Taoran Li, Michael Salerno, Karen Tang, Boon-Keng Kevin Teo

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: The Varian HyperSight imaging solution features a workflow for planning on CBCT images (CBCTp). This study evaluates the feasibility of CBCTp images in the setting of an offline adaptive plan...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

First in-Vivo Proton Radiography Experiments for an Image-Guided Small Animal Irradiation Platform with a TimePix3-Based Detector Setup

Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl

Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam

Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.

Methods:...

Foundation Models with Balanced Data Sampling Enhance Auto-Segmentation for Cardiac Substructures

Authors: Chloe Min Seo Choi, Nikhil Mankuzhy, Aneesh Rangnekar, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Cardiac substructure irradiation predisposes patients for poor outcomes in thoracic radiation therapy. A deep learning model was developed to segment the cardiac substructures invariant to co...

Frameless and Maskless Stereotactic Radiosurgery: Evaluating a Novel Robotic Head Motion Compensation Device

Authors: Michelle Alonso-Basanta, Carl Denis, Wenbo Gu, Xinmin Liu, Ahmad Sakaamini, Rodney D. Wiersma

Affiliation: UCLA, University of Pennsylvania, CDR Systems

Abstract Preview: Purpose: Stereotactic radiosurgery (SRS) is a non-invasive technique used to treat functional abnormalities and small brain tumors. Traditional SRS relies on a rigidly fixed metal head ring, causing d...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Geographic Disparities in Medical Physics Training and Employment: Implications for Rural Workforce Recruitment

Authors: Seth Amofa, Erli Chen, Samuel A. Einstein, Ekinadoese Imudia Frias, Nupur Karmaker, Yinus Kawthara, Dulguun Myagmarsuren, Travis C. Salzillo, Joseph Weygand, Afua A. Yorke

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, University of Washington, Federal University Oye-Ekiti, Cheshire Medical Center, Dartmouth College, Penn State College of Medicine, Dept. of Medical Physics and Biomedical Engineering, Gono Bishwabidyalay, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Virginia Tech Carilion School of Medicine

Abstract Preview: Purpose: Recent developments in the medical physics job market have made it increasingly difficult for radiotherapy centers, particularly in rural areas, to recruit qualified therapeutic medical physi...

High-Temporal Dynamic CBCT Imaging Via Gaussian Neural Representation

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Impact of Jaw Reproducibility and Source Occlusion on Small Field Dosimetry

Authors: Mylinh Dang, Indra J. Das, George X. Ding, Ahtesham Ullah U Khan, Andrew J. White

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine, Vanderbilt University Medical Center

Abstract Preview: Purpose: The large variability in field output factor (FOF) observed among various studies is speculated to be due to uncertainty in jaw reproducibility that is linked directly with source occlusion. ...

Impact of Respiratory Motion and MRI Sequences on Tumour Volume Determination in MR-Guided Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu, Chi To Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose:
The Elekta Unity system facilitates daily adaptive radiotherapy using MRI-based treatment planning. However, MR images are prone to motion artefacts caused by respiratory motion, potential...

Investigation of Prompt Gamma Imaging Using a Three Axis Rotating Compton Camera

Authors: Molokotima Kekana, Dennis S. Mackin, Stephen W. Peterson, Jerimy C. Polf

Affiliation: Department of Physics, University of Cape Town, M3D, Inc, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: To study the imaging characteristics of a prototype prompt gamma (PG) imaging system consisting of multiple rotating Compton cameras (CC).

Methods: The prototype CC imaging system is c...

Measurement of 90 Y Bremsstrahlung Dose with Thermoluminescent Dosimeters

Authors: David P. Adam, Bryan Bednarz, Tyler J Bradshaw, Wesley S. Culberson, Clifford G. Hammer, Sean Jollota, Ohyun Kwon, Jordan Teague

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiology, University of Wisconsin - Madison

Abstract Preview: Purpose: To quantify absorbed dose to water from 90YCl using thermoluminescent dosimeters (TLDs) and to acquire partial volume corrections for 90YCl positron emission tomography (PET).
Methods: Six...

Mid-Range Planning for Efficient and Robust Proton Arc Therapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...

Modeling of Novel Converging Beam Radiotherapy System in Geant4 Montel Carlo Simulation

Authors: Dirk A Bartkoski, Leonard Che Fru, Benjamin Abraham Insley, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour, Aviad Schori, Ramesh C. Tailor

Affiliation: Empyrean Medical Systems, The University of Texas MD Anderson Cancer Center, Convergent-RnR, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose: A Geant4-based model was created for a G4BraggReflection process to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (CRnR...

Monte Carlo Simulation of Dose Perturbations in HAM Applicator HDR Brachytherapy Treatments

Authors: Sam Beddar, Brett Bocian, David B. Flint, Benjamin Abraham Insley, Patrick James Jensen, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Reza Reiazi, Gabriel O. Sawakuchi

Affiliation: University of Miami, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Empyrean Medical Systems, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The Harrison-Anderson-Mick (HAM) applicator is an Ir-192 High-Dose-Rate (HDR) intraoperative radiotherapy device. It features a silicone body with embedded catheters that guide the Ir-192 sou...

Parameterized 4D Deformable Registration (p4Dreg) in Abdominal 4DCT Scans

Authors: Edward Robert Criscuolo, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose:
Deformable registration of 4DCT images has many clinical applications, but current methods are unreliable and can produce dangerous errors. Iterative, parametrized image registration does ...

Positron Emission Tomography

Authors: Osama R. Mawlawi

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: N/A...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

Radiopharmaceutical-Free Assessment of Tumor Vasculature Condition in Particle Therapy By Means of Range-Verification PET: A Feasibility Rat Study

Authors: Go Akamatsu, Han Gyu Kang, Chie Seki, Hitomi Sudo, Hideaki Tashima, Chie Toramatsu, Hidekatsu Wakizaka, Iwao Yamaya, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose:
Tumor oxygen status, which provides important information to optimize particle therapy, may constantly change during a treatment period of several weeks. However, it is impractical to perf...

Reconstructing Radiopharmaceutical Distributions Using Coded Aperture Tomography with Photon Counting Detector

Authors: David P. Adam, Xun Jia, Youfang Lai, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Radiopharmaceutical therapy is experiencing a resurgence in interest due to its potential of treating widespread metastatic disease in a patient-specific manner. Accurately measuring and desc...

Retrospective Analysis of Treatment Pauses Due to Intrafraction Movement for Frameless Single Fraction Gamma Knife Icon Radiosurgery

Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital

Abstract Preview: Purpose: Frameless gamma knife (GK) treatments use a thermoplastic mask coupled with high-definition motion management system that utilizes an infrared camera, and a reflective marker placed on the pa...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

The Impact of Implant Position and Different Radiotherapy Techniques on Dosimetry in Post-Mastectomy Breast Reconstruction for Breast Cancer

Authors: Xiu tong Lin

Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...

Tumor Density on Time-Weighted Mid-Position Images for Thoracic Tumors

Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...

Two-Stage Clustering and Auto Machine Learning to Predict Chemoradiation Response in Tumor Subregions on FDG PET for La-NSCLC

Authors: Stephen R. Bowen, Shijun Chen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Qianqian Tong, Jiajie Wang, Shouyi Wang, Faisal Yaseen

Affiliation: The University of Texas at Austin, Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Fred Hutchinson Cancer Center, University of Texas at Arlington

Abstract Preview: Purpose: Tumor subregion clustering and prediction of region-specific response can augment assessments and adaptive treatment decisions. A modeling framework was constructed to predict chemoradiation ...

Visualization of Irradiation Field in Carbon-Ion Therapy By Openpet: Preliminary Analysis of Clinical Data

Authors: Go Akamatsu, Hiroaki Ikawa, Yuma Iwao, Han Gyu Kang, Masashi Koto, Hideyuki Mizuno, Akram Mohammadi, Makoto Shinoto, Minoru Tajiri, Hideaki Tashima, Chie Toramatsu, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In-beam positron emission tomography (PET), in which positron emitters produced through fragmentation reactions are visualized, is a practical method for range verification in particle therap...