Search Submissions 🔎

Results for "mlc parameters": 57 found

4DCT Contrast Protocol for Cardiac Radioablation

Authors: Jeremy S. Bredfeldt, Cindy I. Hancox, Arianna Liles, Alex Marques, Usha Tedrow

Affiliation: Department of Cardiology, Brigham and Women's Hospital, Harvard Medical School, Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School

Abstract Preview: Purpose: Ventricular tachycardia (VT) can be treated using cardiac radioablation. 4DCT simulation is commonly used, however, contrast injection timing is challenging. This study aimed to develop a pro...

A Framework for Automated Selection of Dose-Volume Objectives to Improve Radiation-Induced Immune Suppression (RIIS)-Related Overall Survival (OS) Following Chemo-Radiotherapy

Authors: Gabriel Lucas Andrade de Sousa, Einsley-Marie Janowski, Cam Nguyen, Krishni Wijesooriya

Affiliation: Department of Radiation Oncology, University of Virginia, Department of Physics, University of Virginia

Abstract Preview: Purpose: Optimizing radiation therapy (RT) to spare the immune system may improve Overall Survival (OS) in cancer patients. This study develops a computational algorithm to identify optimal dose-volum...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

AI-Assisted Algorithm to Generate Patient Postures for Tset Dose Evaluation

Authors: Kostas Danniidis, Agelos Kratimenos, Yufu Wang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to develop software and algorithms utilizing artificial intelligence (AI) to seamlessly create 3D patient postures during Total Skin Electron Therapy (TSET). The resulting mes...

Adapting Newer Treatment Planning Strategy for Uveal Melanoma Cases Using Gamma Knife Radiosurgery

Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan

Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences

Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:

An Efficient Workflow for X-Ray Imaging-Based IGRT/ART

Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Application of the Lymphodose Framework to Brain Tumors: Unveiling the Prognostic Power of Circulating Lymphocyte Doses

Authors: Sophie Bockel, Eric Deutsch, Frederic Dhermain, Ibrahima Diallo, Anh Thu Le, Elaine Limkin, Pauline Maury, Charlotte Robert, Killian Sambourg, Camilla Satragno, Cristina Veres, François de Kermenguy

Affiliation: Gustave Roussy, Département de radiothérapie, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose:
To study the correlation between the dose to circulating lymphocytes as evaluated by the LymphoDose framework and the incidence of severe radiation-induced lymphopenia (sRIL) in patients t...

Assessing the Impact of Weighting Dose Volume Histograms By Variable Relative Biological Effectiveness for Radiation-Induced Lymphopenia Risk Prediction

Authors: Yan Chu, Madison Emily Grayson, Radhe Mohan, Pablo P. Yepes

Affiliation: UT Health Science Center at Houston, Rice University, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Radiation-induced lymphopenia (RIL) is a common adverse effect of radiation therapy, negatively impacting overall survival and anti-PD1 immunotherapy efficacy. Our lab previously developed a ...

Assessment of Material Discrimination Slopes in Dual Energy CT Imaging

Authors: Izabella L. Barreto, Aroon Pressram

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Our clinical dual energy CT (DECT) head protocol reconstructs iodine-suppressed virtual non-contrast (VNC) images using the vendor-recommended slope for material discrimination. However, this...

Big Data in-Vivo Epid Image Prediction for VMAT Radiotherapy

Authors: Casey E. Bojechko, Lance C Moore

Affiliation: University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: EPID images collected during treatment can serve as an in-vivo error detection mechanism. Previous works have shown that comparing in-vivo EPID images to AI-predicted EPID images for IMRT pla...

Brachyplancheck: An Independent Monte Carlo Dose Calculation Tool for Brachytherapy Using Egs_Brachy

Authors: Amy Tien Yee Chang, Chi Wai Cheung, Tin Lok Chiu, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study introduces BrachyPlanCheck, an independent Monte Carlo (MC)-based dose calculation tool for 192Ir brachytherapy retrospective study or algorithm commissioning.
Methods: BrachyPl...

Breathing New Life into Pulmonary Imaging: Development and Clinical Validation of an X-Ray Interferometry System

Authors: Rachael Blair, Les Butler, Lillian Dickson, Kyungmin Ham, Charles Hartman, Kenneth (Kip) Matthews, Corinne Vanya

Affiliation: Louisiana State University, University of Minnesota, Refined Imaging LLC, Center for Advanced Microstructures and Devices

Abstract Preview: Purpose:
To develop and evaluate an x-ray interferometry system (XIS) for low-dose, high-sensitivity diagnostic imaging of lung diseases such as chronic obstructive pulmonary disease (COPD), asthma...

Chat with Oncology Information System Via Large Language Model

Authors: Michael Dohopolski, Xuejun Gu, Hao Jiang, Steve B. Jiang, Christopher Kabat, Jingying Lin, Weiguo Lu, Michael Tang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Neuralrad LLC, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: To streamline access to clinical data stored in Oncology Information Systems such as MOSAIQ or ARIA, we developed an AI-powered chatbot capable of querying, summarizing, and interactively ans...

Comparing SPECT Dose Reconstruction Algorithm Accuracy As a Function of Imaging Parameters

Authors: Srinivas Cheenu Kappadath, Brian Michael Kelley, Benjamin P. Lopez

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Imaging systems are subject to errors from finite spatial resolution and voxel size. This work demonstrates their effect on dose algorithm {Monte Carlo (MC), dose-volume kernel (DVK), and ...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Deep Learning-Based Multileaf Collimator Sequence Prediction for Automated VMAT Treatment Planning in Pancreatic Cancer

Authors: Zixu Guan, Takahiro Iwai, Takashi Mizowaki, Mitsuhiro Nakamura, Michio Yoshimura

Affiliation: Kyoto University, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose:
The goal of this study is to develop a fully automated treatment planning approach for VMAT in pancreatic cancer that can convert patient anatomy into LINAC machine parameters. In this wor...

Determine the Isocenter and Its Size for MR Linac Unity Part2: (u v) of BB and Isocenter Position and Size

Authors: Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...

Developing a Comprehensive Multi-Modal Framework for Population-Scale Liver Volumetry: Insights and Predictive Models

Authors: Mustafa Bashir, Diana Kadi, Kyle J. Lafata, Jacob A. Macdonald, Mark Martin, Yuqi Wang, Marilyn Yamamoto

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Electrical and Computer Engineering, Duke University, Department of Radiology, Duke Unversity

Abstract Preview: Purpose: To develop a high-throughput, automated-data-interrogation pipeline for integrating imaging and clinical information to identify key determinants of liver volume (LV), enabling population-sca...

Enhanced Prediction of Iroc Stereotactic Radiosurgery Phantom Audit Results with Treatment Parameters, Complexity Metrics, DVH, and Dosiomics Using Machine Learning

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Experience in Commissioning and Quality Assurance of Halcyon Linear Accelerator Ver3.0 at a Community Hospital and an Academic Institution

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose:
The Varian Halcyon Linear Accelerator has become increasingly popular in both community hospitals and academic institutions due to its user-friendly design and operational efficiency. This...

Feasibility Study on Creating a Digital Twin of Digital Subtraction Angiography Data Utilizing Monte Carlo and Computational Fluid Dynamic Simulations

Authors: Ciprian N. Ionita, Parisa Naghdi, Ahmad Rahmatpour

Affiliation: University at Buffalo, SUNY: University at Buffalo

Abstract Preview: Purpose: Quantitative angiography (QA) evaluates neurovascular hemodynamics, but is affected by X-ray parameters, vessel foreshortening, and imaging chain factors like detector efficiency, pixel size,...

Impact of Time-of-Flight Reconstruction and Motion Correction on PET-Based Dosimetry in 90y Radioembolization for Hepatocellular Carcinoma

Authors: Spencer Behr, Joseph Grudzinski, Youngho Seo, Jaehoon Shin, Yiran Wang, Frederick J. Wilson

Affiliation: University of California San Francisco, University of California, San Francisco, Voximetry, Inc., Voximetry, Inc

Abstract Preview: Purpose: Voxel-level imaging-based dosimetry enables a significant improvement in accurate and personalized treatment planning in radiopharmaceutical therapy, potentially leading to optimized disease ...

Investigating Interstitial Fluid Pressure and Hydraulic Conductivity By Examining the Biophysical Properties of Drug Transport Using Cross Voxel Exchange Model and Dynamic Contrast Enhanced MRI

Authors: Catherine Coolens, Janny Yeyoung Kim, Michael Milosevic, Noha Sinno

Affiliation: Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: In solid tumors, Interstitial fluid pressure (IFP) acts as a barrier to molecular transport to the tumor center and serves as a predictor of cancer patients’ treatment responsiveness. The nov...

Investigating Racial Differences in 68ga-PSMA-11 PET/CT Imaging for Patients with Biochemical Recurrence after Radical Prostatectomy: Preliminary Findings

Authors: Maya Ataya, Clint Bahler, Ramotallah Dami Jubril, Michael Koch, Oluwaseyi Oderinde, Mark Tann

Affiliation: Purdue University, epartment of Urology, Indiana University School of Medicine, Department of Urology, Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indiana University School of Medicine

Abstract Preview: Purpose:
To investigate racial differences in the detection of biochemical recurrence (BCR) using 68Ga-PSMA-11 PET/CT, known for its improved sensitivity and specificity in patients after radical p...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Longitudinal CMR Strain Analysis of Right Ventricular (RV) Function across Aging in Offspring of Baboons Exposed to Moderate Maternal Undernutrition

Authors: Geoffrey D. Clarke, Laura A. Cox, Alexander J Moody, Peter W Nathanielsz, Bowen Yang

Affiliation: Wake Forest University School of Medicine, University of Texas Health Science Center at San Antonio, Texas Biomedical Research Institute

Abstract Preview: Purpose:
Recent studies show diagnostic value of myocardial strain analysis for left ventricular (LV) function using cardiac magnetic resonance imaging (CMR). RV function analysis is more challengi...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Lymph Node Dose Is Associated with Immune Suppression and Poor Overall Survival in Locally Advanced Non-Small Cell Lung Cancer (NSCLC)

Authors: Ryan Gentzler, Xin He, James Larner, J.T. Morgan, Cam Nguyen, Wendy Stewart, Krishni Wijesooriya, Grant Williams

Affiliation: Department of Physics, University of Virginia, Department of Radiation Oncology, University of Virginia, Division of Hematology & Oncology, Department of Medicine, University of Virginia

Abstract Preview: Purpose: Some recent studies have shown Overall Survival (OS) of advanced-stage lung cancer patients treated with chemo-radiation therapy (CRT) is correlated with heart dose [1-5], while in other stud...

Monte Carlo Simulation of Surface Radiation Dose for Cherenkov Imaging: Comparison with Commissioning Data for Truebeam and Halcyon

Authors: Hongjing Sun, Weibing Yang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to compare the commissioning results of TrueBeam and Halcyon linear accelerators with Monte Carlo (MC) simulations conducted using TOPAS. The ultimate goal is to leverage MC s...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

Neural Network Based Differentiable Optimization for Volumetric Modulated Arc Therapy (VMAT)

Authors: Peng Dong, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University

Abstract Preview: Purpose: Volumetric Modulated Arc Therapy (VMAT) optimization is a complex, non-convex problem with numerous variables and intricate constraints. Traditional optimization methods often lack efficiency...

Optimizing the Design for a Directional Brachytherapy Source

Authors: Akire Trestrail

Affiliation: University of Wisconsin

Abstract Preview: Purpose: To investigate the feasibility of using 125I as a HDR directional brachytherapy source.
Methods: Monte Carlo (MC) simulations were performed using the EGSnrc software toolkit. Dose rate di...

Personalized Organ Dose Estimation Using Monte Carlo Simulations, Auto-Segmentation, and Anatomical Extension from Clinical CT Scans

Authors: Belen Juste, Choonsik Lee, Matthew Mille, Rafael Miró, Sergio Morato Rafet, Agustin Santos, Gumersindo Verdú

Affiliation: Division of Cancer Epidemiology and Genetics, National Cancer Institute, Universitat Politècnica de València, Servicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, National Cancer Institute

Abstract Preview: Purpose: To evaluate the differences in CT scan radiation dose estimation between personalized dose reconstruction, based on real patient CT images, and generalized phantom-based dose calculations.

Plan Optimization Parameter Impact on Gamma Pass Rates

Authors: Parham Alaei, Timothy J Allen, Tomas Agustin Montenegro

Affiliation: University of Minnesota, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose:
To assess possible relationships between treatment plan optimization parameters and gamma pass rates in quality assurance (QA) analysis of IMRT/VMAT plans.
Methods:
Plan optimization...

Proactive Quality Assurance for Adaptive Radiotherapy: Real-Time Mlc Verification with Myqa SRS

Authors: James L. Giltz, Michael J. Merrick

Affiliation: Alyzen Medical Physics, University of Kentucky

Abstract Preview: Purpose: To evaluate the capability of MyQA SRS in performing high-resolution machine QA to verify multileaf collimator (MLC) behavior and integrity for adaptive radiotherapy (ART). This study demonst...

Radiation Sub-Segmentectomy in 90y Radioembolization: Post-Therapy Dosimetry, Treatment Response, and Pathological Necrosis

Authors: Guilherme Rosa Ferreira, Dan Giardina, John Karageorgiou, Chris Malone, Allan Thomas

Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Radiation segmentectomy has become a primary strategy in 90Y radioembolization, with localized treated volumes that can include up to two liver segments. The goal is complete pathological nec...

Radio-Immune Response Model for the Personalized Ultrafractionated Stereotactic Adaptive Radiotherapy (PULSAR)

Authors: Young-Bin Cho, Robert Timmerman

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Cleveland Clinic

Abstract Preview: Purpose: Immunologically hot (MC38) and cold (LLC) tumor in mouse were treated with radiation and/or immunotherapy agent for the study of Personalized Ultrafractionated Stereotactic Adaptive Radiother...

Recovery Factor Comparisons for Reirradiation Overlapping the Spinal Cord

Authors: Xinxin Deng, Issam M. El Naqa, Jimm Grimm, Lijun Ma, Vitali Moiseenko, Timothy E. Schultheiss, Gopal Subedi, Wolfgang A. Tomé, Ellen D. Yorke, Albert van der Kogel

Affiliation: Montefiore Medical Center, Wellstar Kennestone Hospital Cancer Center, H. Lee Moffitt Cancer Center, Department of Human Oncology, University of Wisconsin–Madison, Department of Radiation Oncology, Wellstar Health System, Radiation Oncology, Keck School of Medicine of USC, Georgia Institute of Technology, University of California San Diego, City Of Hope National Medical Centre, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Reirradiation is increasingly utilized in clinical practice but dose-time recovery factors for human subjects remain uncertain. We constructed a reirradiation recovery model for spinal cord e...

Reinforcement Learning Based Machine Parameter Optimization for Two-Arc Prostate VMAT Planning

Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...

Repeatability of Quantitative 3D T1ρ Imaging in Head and Neck Cancer

Authors: Sandeep Panwar Jogi, Nancy Lee, Ricardo Otazo, Ramesh Paudyal, Qi Peng, Akash Shah, Amita Shukla-Dave, Can Wu

Affiliation: Department of Radiology, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiology, Albert Einstein College of Medicine and Montefiore Medical Center

Abstract Preview: Purpose: Quantitative T1ρ imaging provides enhanced tissue characterization beyond standard T1 and T2 parameters, potentially supporting early-stage longitudinal monitoring of head and neck cancer. Th...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

The Topas Monte Carlo Framework – Status and Outlook after 15 Years of Development

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Thongchai Masilela, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin

Affiliation: University of California San Francisco, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital

Abstract Preview: Purpose: To present the results of 15 years of developments of the TOPAS TOol for PArticle Simulation framework, and to highlight recent and new developments.

Methods: Fundamental understanding...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...

Transformations of the Coordinate System for Monte Carlo Dose Calculations of Spot Scanning Proton Therapy

Authors: Hongyu Jiang

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: This study presents a method for transforming coordinates from RayStation’s treatment planning system into the Monte Carlo (MC) coordinate system used in GEANT4 for dose calculations in spot ...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Treatment Plan Comparisons of Head and Neck Cancers on Varian Ethos/Halcyon and Truebeam Linac

Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...

Using Machine Learning to Predict Esophagitis Risk in Lung Cancer Radiotherapy Based on Clinical and Dosimetric Factors

Authors: Ibtisam Almajnooni, Siyong Kim, Nathaniel Miller, Elisabeth Weiss, Lulin Yuan

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: Radiation-induced esophagitis (RE) is a common concern in lung cancer IMRT. Recent studies have indicated that the risk of radiation side effects varies greatly with patients’ baseline clinic...

Using a Generative Adversarial Network (GAN) for Source Particle Generation in Monte Carlo Radiation Therapy Simulations

Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions

Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

VMAT Machine Parameter Optimization Using Policy Gradient Reinforcement Learning

Authors: Avinash Mudireddy, Nathan Shaffer, Joel J. St-Aubin

Affiliation: University of Iowa

Abstract Preview: Purpose: This work demonstrates preliminary results in training a reinforcement learning (RL) network to perform VMAT machine parameter optimization.
Methods: We implemented a policy gradient RL al...