Search Submissions 🔎

Results for "modulated proton": 51 found

A Causal Machine Learning Analysis of Dosimetric and Clinical Predictors of Osteoradionecrosis in Head and Neck Cancer Radiotherapy

Authors: Jingyuan Chen, Sheng Li, Tianming Liu, Wei Liu, Zhengliang Liu, Zhong Liu, Daniel Ma, Samir H. Patel, Guangya Wang, Yunze Yang

Affiliation: University of Miami, Mayo Clinic, School of Data Science, University of Virginia, School of Computing, University of Georgia, Department of Radiation Oncology, Mayo Clinic, Institute of Western China Economic Research, Southwestern University of Finance and Economics

Abstract Preview: Purpose:
Traditional patient outcome analyses relied heavily on conventional statistical models that primarily elucidate correlation rather than causal relationships. In this study, we aim to ident...

A Deep Learning-Based Method for Rapid Generation of Spot Weights in Single Field Optimization for Proton Therapy in Prostate Cancer

Authors: Yu Chang, Mei Chen

Affiliation: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine

Abstract Preview: Purpose: Spot weights optimization, as a critical step in the proton therapy, is often time-consuming and labor-intensive. Deep learning, with its powerful learning and computational efficiency, can e...

A Dosimetric Investigation into the Potential of Aperture-Based Techniques to Improve the Clinical Outcomes of Single-Energy Proton Bragg Peak Flash Therapy for Ocular Cancers

Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng

Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...

A Dosimetric Study of Range-Compensated Proton Arc Therapy

Authors: Alonso N. Gutierrez, Daniel E. Hyer, Blake R. Smith

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To perform a feasibility study of optimizing and producing a compact range compensator to deliver single-energy pencil beam scanning (PBS) proton arc therapy treatments. Omitting energy chang...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A Novel Lattice Technique Based Spot Scanning Proton Arc Therapy Via Spot Sparsity Optimization and LET Optimization

Authors: Zhitao Dai, Riao Dao, Xuanfeng Ding, Qingkun Fan, Yajun Jia, Gang Liu, Gang Peng, Yujia Qian, Hong Quan, Kunyu Yang, Sheng Zhang, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Corewellhealth William Beaumont University Hospital, School of Mathematics and Statistics, Wuhan University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Chinese Academy of Medical Sciences Cancer Hospital Shenzhen Hospital, School of Physics and Technology,Wuhan University, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: Lattice radiation therapy (LRT) is an innovative three-dimensional(3D) implementation type of spatially fractionated radiation therapy (SFRT). This study aims to develop a novel spot-scanning...

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

A Quantitative Metric for Evaluating Treatment Plan Robustness in Intensity Modulated Proton Therapy

Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Stephen Shang

Affiliation: South Florida Proton Therapy Institute, SFPRF

Abstract Preview: Purpose: Proton pencil beam scanning therapy is particularly sensitive to field translational shifts and beam range variations, which can degradation of dose distribution and compromise the treatment....

An Energy Layer Optimization Approach for Spot Scanning Proton Arc Therapy

Authors: Wenhua Cao, Hadis Moazami Goudarzi, Madison Emily Grayson, Zongsheng Hu, Gino Lim, Steven Hsesheng Lin, Radhe Mohan

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Industrial Engineering, University of Houston, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) offers significant potential in treating complex cancer cases by delivering a continuous radiation dose as the gantry rotates. This study aims to investigate the pote...

Automated Decision Workflow Using Fast Monte Carlo Dose Calculations for Daily Adaptive Proton Therapy

Authors: Ergun E. Ahunbay, Abdul Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao

Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Online adaptive replanning is often necessary in Intensity Modulated Proton Therapy (IMPT) due to the sensitivity of proton dose distributions to daily anatomical changes. A rapid, automated ...

Automated IMPT Treatment Planning for CSI: Enhancing Efficiency with Auto-Segmentation and Scripting

Authors: Katja M. Langen, William Andrew LePain, Robert Muiruri, Vivi Nguyen, Mosa Pasha, Roelf L. Slopsema, Alexander Stanforth, Yinan Wang, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) treatment planning for craniospinal irradiation (CSI) is complex and requires extensive effort from the planner. This study aims to enhance planning ...

BEST IN PHYSICS MULTI-DISCIPLINARY: Evaluation of Spot-Level N-12 PET Imaging for Online Range Verification in Multi-Field Intensity Modulated Proton Therapy

Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos

Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen

Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...

Beam Orientation Optimization in IMRT Using Sparse Mixed Integer Programming and Non-Convex IMRT Fluence Map Optimization

Authors: Yabo Fu, Yang Lei, Yu Lei, Haibo Lin, Ruirui Liu, Tian Liu, Kenneth Rosenzweig, Charles B. Simone, Shouyi Wei, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York Proton Center

Abstract Preview: Purpose: Beam orientation optimization (BOO) in intensity-modulated radiation therapy (IMRT) is traditionally a complex, non-convex problem tackled with heuristic methods. This study benchmarks global...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

CT-on-Rails Longitudinal Image Quality Stability for Intensity Modulated Adaptive Proton Therapy

Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao

Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...

Comparison of Linear Energy Transfer Volume Histograms from Two Beam Geometries in a Pediatric Chordoma Patient Treated with Intensity Modulated Proton Therapy

Authors: Michael Confer, Mark A. Newpower

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: A pediatric patient recently presented to our clinic for treatment for chordoma, which was near the brainstem. The clinician elected to treat this patient using intensity modulated proton the...

Comprehensive Assessment of Intra-Fractional and Inter-Fractional Motion in Intensity-Modulated Proton Therapy for Esophageal Cancer

Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin

Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: The purpose of this study was to investigate the interplay effect during intra-fractional motion and the effect of the robust optimization parameters for inter-fractional motion in the intens...

Correlating Cochlear Hearing Loss from Head and Neck Proton Therapy to Variable Relative Biological Effectiveness Dose

Authors: Angela Gathers, Christina Henson, Sakuntala Jagabattuni, Mark A. Newpower

Affiliation: University of Oklahoma HSC, Department of Otolaryngology, University of Oklahoma HSC, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: A previous departmental study showed an increase in ototoxicity (hearing loss) rates in head & neck cancer (HNC) patients treated with Intensity Modulated Proton Therapy (IMPT) vs. x-ray radi...

Development and Experimental Validation of an in-House Proton Treatment Planning System with Energy Layer Optimization

Authors: Hao Gao, Yuting Lin, Jufri Setianegara, Aoxiang Wang, Peng Xiao, Qingguo Xie, Yanan Zhu

Affiliation: Department of Biomedical Engineering, Huazhong University of Science and Technology, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity-modulated proton therapy (IMPT) achieves uniform tumor dose distribution while sparing organs-at-risk (OAR) by optimizing spot weights across energy layers. Accelerating IMPT delive...

Development of a Beam Profile Variation Observation Model for Intensity Modulated Radiotherapy

Authors: Kaile Li

Affiliation: Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...

Development of a Knowledge-Based Planning Model for Intensity Modulated Proton Therapy in Breast Cancer Treatment

Authors: Parker Anderson, Elizabeth L. Bossart, Jonathan Cyriac, Nesrin Dogan, Robert Kaderka, Yihang Xu

Affiliation: University of Miami, University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
Knowledge-based planning (KBP) can enhance the treatment planning process in cancer radiotherapy (RT). By training a KBP model with high-quality treatment plans developed by experts, dose-...

Development of a Quantitative Surface Mapping Analysis Framework Involving a Robust Mask Removal Algorithm for Improved Objective Patient Setup Assessment in Head and Neck Intensity Modulated Proton Therapy

Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Michael H. Shang, Stephen Shang, Timothy R Williams

Affiliation: South Florida Proton Therapy Institute, SFPRF, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose:
Daily image guidance for head and neck intensity-modulated proton therapy (IMPT) presents significant challenges due to large target volumes and anatomical changes. Geometric deviations al...

Dosimetric Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT Techniques: Analysis with Central and Peripheral Lung Tumors

Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav

Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute

Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...

Efficient Denoising of Low-Statistic Influence Matrices Using a Diffusion Transformer-Based Framework for Adaptive Proton Therapy

Authors: Yuzhen Ding, Hongying Feng, Jason Michael Holmes, Baoxin Li, Wei Liu, Daniel Ma, Lisa McGee, Samir H. Patel, Jean Claude M. Rwigema, Sujay A. Vora

Affiliation: Arizona State University, Department of Radiation Oncology, Mayo Clinic, Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
Intensity-modulated proton therapy (IMPT) is a preferred treatment modality for head and neck (H&N) cancer patients, offering precise tumor targeting while sparing surrounding organs at ri...

Efficient Robustness Optimization in Intensity Modulated Proton Therapy for Head and Neck Cancer Via Visual State Space Attention Generative Adversarial Networks (VSSA-GAN)

Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang

Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...

Evaluating Discrete Proton Arcs Converted to Pencil Beam Scanning Plans for Glioma and Chordoma in Raystation with a Mevion s250i Hyperscan Proton Therapy System

Authors: Mark A. Newpower, Jill Taylor

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: RayStation 2024A allows planners to optimize intensity modulated proton therapy (IMPT) plans using discrete arcs which can then be converted to traditional pencil beam scanning (PBS) beams fo...

Evaluation of Dose-Rate Metrics in Intensity Modulated Proton Therapy for Prostate Cancer Treatments

Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University

Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...

Evaluation of Dosimetric Variations from Anatomical Changes in Head and Neck Cancer Patients Treated with Intensity Modulated Proton Therapy

Authors: Chia-Lung Chien, Wen C. Hsi, Romy Megahed, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
The dosimetric variations induced by inter-fractional anatomical changes in intensity-modulated proton therapy could impact the clinic outcomes for head-and-neck (HN) cancer patients. This...

Evaluation of Fast Monte Carlo Secondary Dose Calculation for Intensity Modulated Proton Therapy in Heterogeneous Materials

Authors: Ergun E. Ahunbay, Abdul Kareem Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao

Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Secondary dose calculations (SDC) facilitate patient-specific quality assurance for online adaptive intensity-modulated proton therapy (IMPT). However, there is currently a lack of commercial...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Feasibility and Dosimetric Impact of Intensity-Modulated Radiotherapy for Cervical Cancer Patients in Nepal: A Retrospective Analysis

Authors: Daniela Branco, John M Bryant, Surendra Bahadur Chand, Pratiksha Shahi, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, B.P. Koirala Memorial Cancer Hospital, , B.P Koirala Memorial Cancer Hospital, University of California San Diego / California Protons, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose:
Cervical cancer remains a significant health burden in Nepal, with 2169 new cases and 1313 deaths recorded in 2022. This study evaluates the feasibility of implementing step-and-shoot IMRT...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

Implementation of a Visual Feedback System for Respiratory Gated Intensity Modulated Proton Therapy

Authors: Shen Fu, Jun Hou, Zuofeng LI, Taize Yuan, Qingyuan Zhang, Yuanshui Zheng

Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center, 广州泰和肿瘤医院

Abstract Preview: Purpose: A visual feedback system is beneficial for patients to maintain consistent respiratory signal during gated radiotherapy, especially for intensity modulated proton therapy (IMPT) where motion ...

Investigation of the Correlation between Proton Linear Energy Transfer and Treatment Field Hinge Angles in Brain Tumor Patients Treated with Intensity Modulated Proton Therapy

Authors: Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Minesh P. Mehta, Andrew J. Wroe, Jen Yu

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: Linear energy transfer (LET) is directly related to relative-biological-effectiveness dose in proton therapy. This study aims to investigate how the treatment field hinge angles affect LET of...

Investigations on Intensity-Modulated Proton Therapy Robust-Optimization Strategies and Their Dosimetric Effects on Head and Neck Cancers

Authors: Shen Fu, Zhangmin LI, Zuofeng LI, Yuanshui Zheng

Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center

Abstract Preview: Purpose: To investigate the influence of different robustness optimization strategies and parameters in proton therapy plans for head and neck tumors on target coverage and OAR (organ at risk) sparing...

Knowledge-Based Planning in Proton Therapy: Validation and Model Size Considerations with Limited Data

Authors: Gregory A Azzam, Michael Butkus, Nesrin Dogan, Robert Kaderka, Nhan Vu, Yihang Xu

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, University of Miami, Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Knowledge-based planning (KBP) has demonstrated potential for improving planning quality and efficiency. Adoption of KBP in particle therapy has been slow due to limited number of plans to tr...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Maximum Conformity IMPT Planning with the Dynamic Collimation System

Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care

Abstract Preview: Purpose:
To perform end-to-end treatment planning and delivery verification of energy-specific collimated treatments optimized to achieve the maximum obtainable high-dose conformity using the dynam...

Mid-Range Planning for Efficient and Robust Proton Arc Therapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...

Multi-Region Multiomic Features Improve Random Forest Toxicity Modeling of Radiation Pneumonitis

Authors: Laurence Edward Court, Alexandra Olivia Leone, Zhongxing Liao, Saurabh Shashikumar Nair, Joshua S. Niedzielski, Ramon Maurilio Salazar, Ting Xu

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Radiation Pneumonitis (RP) predictive models often rely on clinical and DVH parameters, but multiomic features from CT imaging and 3D dose distributions from various regions could provide add...

Optimizing Minimum Monitor Unit Thresholds for Proton Breast Therapy on the Iba Proteusone

Authors: Chia-Lung Chien, Wen C. Hsi, Faraz Kalantari, Pouya Sabouri, Man Yam

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Reducing treatment delivery time is critical to improving patient throughput and minimizing the risk of intrafraction motion, which can compromise treatment accuracy. This study identifies...

Patient-Specific Deep Reinforcement Learning Framework for Automatic Replanning in Proton Therapy for Head-and-Neck Cancer

Authors: Malvern Madondo, Mark McDonald, Zhen Tian, Christopher Valdes, Ralph Weichselbaum, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Emory University, Department of Radiology, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Head-and-neck (HN) cancer patients often experience significant anatomical changes during treatment course. Proton therapy, particularly intensity-modulated proton therapy (IMPT), is sensitiv...

Patient-Specific Orthogonal Projection Based Real-Time Volumetric X-Ray Imaging for Proton Therapy

Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...

Proton Pencil Beam Scanning Ultra-High Dose Rate 3D Lattice Radiotherapy: A Proof-of-Concept Flash Sfrt Study

Authors: Richard Bakst, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Minglei Kang, Nancy Y Lee, Haibo Lin, Hang Qi, Charles B. Simone, Pingfang Tsai, Milo Vermeulen, Shouyi Wei, Xiaodong Wu, Lee Xu, Irini Yacoub, Xingyi Zhao, Ajay Zheng

Affiliation: University of Miami, Peking University, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, icahn school of medicine at mount sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Three-dimensional lattice radiation therapy (3D-LRT) effectively achieves local tumor control with limited morbidity. Pencil beam scanning (PBS) proton therapy provides precise dose confor...

Radial Waveguide Structures for Enhanced Power Transmission Efficiency in Dielectric Wall Accelerators

Authors: Julien Bancheri, Chau Giang Bui, David G Cooke, Christopher M Lund, Morgan J Maher, Jan P. Seuntjens, Jason Z Yuan

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Medical Biophysics, University of Toronto, University of Toronto, Medical Physics Unit, McGill University, Department of Physics, McGill University

Abstract Preview: Purpose: The dielectric wall accelerator (DWA) offers a low-cost solution for proton therapy, using non-resonant waveguides to accelerate particles. Radial waveguides (RWGs), consisting of a dielectri...

The Impact of Implant Position and Different Radiotherapy Techniques on Dosimetry in Post-Mastectomy Breast Reconstruction for Breast Cancer

Authors: Xiu tong Lin

Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...

Two Radiochemical Monte Carlo Models to Investigate the Radical Yields Under Proton Flash Irradiations

Authors: Yujie Chi, Yao Hao, Xun Jia, Youfang Lai, Yuting Peng, Francisco Javier Reynoso, Lingshu Yin, Tianyu Zhao, Xiandong Zhao

Affiliation: Johns Hopkins University, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Physics, University of Texas at Arlington, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, University of South Florida

Abstract Preview: Purpose: FLASH radiation therapy has shown remarkable tissue sparing effects compared to radiation therapy at conventional dose rates (CDR). Yet, its mechanism remains unclear. Radical production modu...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Using Single-Energy Bragg Peak (SEBP) Flash Combined with Intensity-Modulated Proton Therapy (IMPT) for Flash Treatment in a Clinical Synchrotron-Based Proton System

Authors: Chingyun Cheng, Ben Durkee, Carri K. Glide-Hurst, Minglei Kang, Haibo Lin, Bhudatt R. Paliwal, Charles B. Simone, Zhizhen Wei, Tengda Zhang, Xingyi Zhao

Affiliation: University of Wisconsin, Department of Mechanical Engineering, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Transmission Beam (TB), Single-Energy Bragg Peak (SEBP), and Single-Energy Spread-Out Bragg Peak (SESOBP) are primary proton conformal FLASH techniques. However, each comes with significant l...

When Protons Are Unavailable: Study of High Quality Knowledge-Based Planning Models for the Treatment of Unilateral Head and Neck Patients

Authors: Kenny Guida, Daniel Johnson, Wesley Tucker

Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...