Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts
Affiliation: University of Michigan, Oregon Health & Science University
Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...
Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta
Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...
Authors: Xiu tong Lin, Tao Sun
Affiliation: Department of Radiation physics and technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation physics and technology, Shandong Second Provincial General Hospital
Abstract Preview: Purpose: To compare the positioning accuracy and time efficiency of "Sphere-Mask" Optical Positioning System (OPS) and traditional laser light positioning method in breast cancer radiotherapy, and to ...
Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price
Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.
Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...
Authors: Michael Cuddy, Samuel J. Fahrenholtz, Khushnood Hamdani, Saman Jirjes, Robert G. Paden, Jeremiah W. Sanders, William F. Sensakovic, Wolfgang Stefan, Jeffrey Xiao, Yuxiang Zhou
Affiliation: Mayo, Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Title: An automated system for MRI coil performance evaluation
Purpose: To develop an automated quality control (QC) system for MRI coils to assess element-level signal-to-noise ratio (SNR), ar...
Authors: David Alejandro Collazos Burbano, Antonio Adilton Oliveira Carneiro, Paul L. Carson, Jose Eduardo Freire, Theo Zeferino Pavan, Joao Henrique Uliana, Nicholas Zufelato
Affiliation: University of São Paulo, University of Michigan, University of Sao Paulo
Abstract Preview: Purpose: Develop a theranostic platform that integrates magnetic hyperthermia (MH), ultrasound, and magnetic nanoparticles (MNPs) to improve diagnosis, treatment, and monitoring of hyperthermia proced...
Authors: Hajar Moradmand, Lei Ren
Affiliation: University of Maryland School of Medicine, University of Maryland
Abstract Preview: Purpose:
The Sharp-van der Heijde (SvH) score is essential for assessing joint damage in rheumatoid arthritis (RA) from radiographic images. However, manual scoring is time-intensive and prone to v...
Authors: Rachael Blair, Les Butler, Lillian Dickson, Kyungmin Ham, Charles Hartman, Kenneth (Kip) Matthews, Corinne Vanya
Affiliation: Louisiana State University, University of Minnesota, Refined Imaging LLC, Center for Advanced Microstructures and Devices
Abstract Preview: Purpose:
To develop and evaluate an x-ray interferometry system (XIS) for low-dose, high-sensitivity diagnostic imaging of lung diseases such as chronic obstructive pulmonary disease (COPD), asthma...
Authors: Xiaoda Cong, Rohan Deraniyagala, Xuanfeng Ding, Xiaoqiang Li, Jian Liang, Peilin Liu, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose:
Commission a step-and-shoot arc therapy(SPArc-step&shoot) for treating head-neck cancer patients as a desired interim milestone toward full dynamic treatment.
Methods:
An in-house de...
Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie
Affiliation: Novant Health Cancer Institute, Novant Health
Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...
Authors: Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Vikas Vikas, Brian C. Wilson, Weibing Yang, Timothy C. Zhu
Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania
Abstract Preview: Purpose:
Multispectral Singlet Oxygen Luminescent Dosimetry (MSOLD) has been developed as a real-time in vivo dosimetry technique for Photodynamic Therapy (PDT). This study investigates the feasibi...
Authors: Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Surface imaging has been used clinically more regularly. The accuracy of several commercial products has been studied. AAPM TG302 also has proposed the system quality assurance and commission...
Authors: Sorour Hosseini, YuHuei Jessica Huang, Jeremy Kunz, Nicholas Pierre Nelson, Ryan G. Price, Prema Rassiah, Hui Zhao
Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah
Abstract Preview: Purpose: To investigate the feasibility and clinical implications of creating customized workflows in a new SGRT system: LUNA 3D (LAP, Florida).
Methods: Three clinical SGRT workflows were designed...
Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai
Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...
Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang
Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison
Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...
Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler
Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...
Authors: Theresa Busch, Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Brian C. Wilson, Weibing Yang, Timothy C. Zhu
Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania
Abstract Preview: Purpose: Direct detection of singlet-state oxygen (¹O₂) is crucial for advancing type II photodynamic therapy (PDT), but its short lifetime makes in vivo measurement highly challenging. Although Photo...
Authors: Kristina Bjegovic, Yong Chen, Lucia Rodriguez Gonzalez, Marti Roper, Liangzhong Xiang
Affiliation: University of California, Irvine, University of California Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center
Abstract Preview: Purpose: Proton therapy is an increasingly popular cancer treatment due to its precision, enabled by the Bragg Peak (BP), which minimizes side effects. This profile necessitates in-patient localizatio...
Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous, Roman Vasyltsiv, Rongxiao Zhang
Affiliation: Dartmouth Health, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri
Abstract Preview: Purpose: On-patient dosimeters assist in clinical decision-making by measuring surface dose, but single-point measurements cannot monitor area-wide distributions and are misleading in high-gradient re...
Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan
Affiliation: University of California, Irvine
Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...
Authors: Adi Robinson, Michael J. Tallhamer
Affiliation: Centura Health, AdventHealth Orlando
Abstract Preview: Purpose: This study aims to evaluate the integration of Cherenkov imaging into radiation therapy practices, focusing on its utility in enhancing treatment precision, patient safety, and clinical decis...
Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng
Affiliation: UC San Diego, UCSD, University of California San Diego
Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...
Authors: Neha Devi, Deon M. Dick
Affiliation: Jaeger Corporation
Abstract Preview: Purpose: To evaluate the impact of bladder volume variation on small bowel dose in prostate cancer patients with nodal involvement and assess the efficacy of a 'half-full bladder' guideline for minimi...
Authors: Victoria Noelle Bry, Tamara Egan, Eric C. Ford, Angelia Landers, Juergen Meyer
Affiliation: Fred Hutch Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington
Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) can improve patient safety, however, its complex integration may expose processes to increased risk of error. This work identifies potential failures f...
Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...
Authors: Ingrid S. Reiser
Affiliation: University of Chicago
Abstract Preview: N/A...
Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang
Affiliation: Levine Cancer Institute, Atrium Health
Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...
Authors: Wookjin Choi, James M. Lamb, David Romanofski, David H. Thomas, Yevgeniy Vinogradskiy
Affiliation: Drexel, Department of Radiation Oncology, University of California, Los Angeles, Thomas Jefferson University
Abstract Preview: Purpose: To develop an intelligent Black Box Recorder for radiation therapy (RT) that monitors patient treatments using a vision language model.
Methods: The system captures synchronized screen rec...
Authors: Ananta Raj Chalise, Matthias K Gobbert, Hajar Moradmand, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang
Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, University of Maryland, Baltimore County, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc
Abstract Preview: Purpose: We are developing a novel Compton Camera (CC) system mounted orthogonally on the treatment nozzle for prompt gamma (PG) imaging-based proton range verification during treatment. This study in...
Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater
Affiliation: Saint Louis University
Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patients’ setups. MAHR complements current image-guidance...
Authors: Zhongping Chen, Yuchen Song, Leshan Sun, Liangzhong Xiang, Yifei Xu
Affiliation: University of California, Irvine, University of California Irvine
Abstract Preview: Purpose: Electroacoustic tomography (EAT) monitors the distribution of electrical energy in tissues by detecting acoustics signals induced by electrical pulses during irreversible electroporation (IRE...
Authors: Hisham Assi, Lexi Dowdy, Muhannad N. Fadhel, Michael C. Kolios, Carl Kumaradas, Rasha S Makkia, Tanay N Mannikar
Affiliation: Toronto Metropolitan University, Augusta University, Institute for Biomedical Engineering, Science and Technology (iBEST), Li Ka Shing Knowledge Institute, St. Michael’s Hospital, Northwestern University, Medical College of Georgia, Augusta University
Abstract Preview: Introduction: Hyperthermia is an emerging strategy for cancer treatment due to its few side effects and low cost. Hyperthermia is used in conjunction with other treatments, such as radiation therapy, ...
Authors: Stephen F. Kry, Andrea Molineu
Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center
Abstract Preview: Purpose: This study aims to introduce knowledge and tools from the fields of implementation science and change management to the medical physicist.
Methods: Medical physicists often implement new t...
Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu
Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health
Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...
Authors: Jeremy S. Bredfeldt, Daniel W. Cail, Maria A. Czerminska, Cindy I. Hancox, David Hu, Benjamin Karasko, Claire Keun Sun Park
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Brigham and Women's Hospital, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: To develop a robust clinical protocol for in vivo dosimetry in radiotherapy using the myOSLchip Optically Stimulated Luminescent Dosimeter (OSLD) system by performing characterization and eva...
Authors: Teh Lin, Anna Oneil
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...
Authors: Sean D. Rose
Affiliation: University of Texas at Houston Medical School
Abstract Preview: N/A...
Authors: Ali Ammar, Quan Chen, Jingwei Duan, Yi Rong, Nathan Y. Yu, Libing Zhu
Affiliation: Mayo Clinic Arizona, University of Alabama at Birmingham
Abstract Preview: Purpose: Clinical performance of deep learning-based auto-segmentation (DLAS) can degrade over time due to AI “aging” from unseen data input compared to the initial model training data. This study aim...
Authors: Robert Sánchez Casanueva
Affiliation: Servicio de Física Médica. Hospital Clínico San Carlos
Abstract Preview: N/A...
Authors: Kristina Bjegovic, Luke Connell, Emil Schueler, Leshan Sun, Lucy Whitmore, Liangzhong Xiang
Affiliation: University of California, Irvine, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: The use of FLASH-RT in the clinic would greatly reduce off-target radiation toxicity in normal tissues. However, due to the hypo-fractionated delivery of prescribed doses at FLASH dose rates,...
Authors: Jadon O Buller, Yankun Lang, Liangzhong Xiang, Andrea Paulina Yanez
Affiliation: University of Maryland School of Medicine, University of California, Irvine
Abstract Preview: Purpose: With the widespread adoption of electroporation, there is growing interest in deep-tissue electric field monitoring. Electroporation therapy ablates target regions by generating electric fiel...
Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang
Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...
Authors: Marian Axente, Mandeep Kaur
Affiliation: Emory University
Abstract Preview: Purpose: To validate a low-cost optical imaging system for respiratory monitoring by comparing its accuracy and feasibility against the clinical gold standard in human subjects.
Methods: Following ...
Authors: Joke Binst, Hilde TC Bosmans, Niki Fitousi, Bram Miseur, Dimitar Petrov, Kwinten Torfs, Janne Vignero
Affiliation: Qaelum NV, Department of radiology, UZLeuven, Department of imaging and pathology, KULeuven
Abstract Preview: Purpose: Routine quality monitoring in CT abdomen is crucial for ensuring optimal image quality and patient safety, but the simultaneous evaluation of all aspects of importance is challenging. The pur...
Authors: Amanda J. Deisher, Susannah V. Hickling, Shima Ito, Jon J. Kruse
Affiliation: CancerCare Manitoba, Mayo Clinic
Abstract Preview: Purpose:
To date, 11 ocular patients were treated with spot scanning gantry-based gaze-gated ocular proton program at Mayo Clinic, Rochester MN since 2023. Treatments are done in the half-arc gantr...
Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...
Authors: Guillermo Daniel Alvarez, Daniel Fino, Rocio Luz Gilli, Dorian Alexander Romero
Affiliation: School Foundation of Nuclear Medicine, INTECNUS Foundation, Nuclear Medicine and Radiotherapy Center of Southern Patagonia
Abstract Preview: Purpose: To evaluate the anatomical, functional, and molecular information from PET/MR images with F18-PSMA to identify intraprostatic lesions and delineate a boost in stereotactic body radiotherapy (...
Authors: Lawrence T. Dauer, Yusuf Emre Erdi, Yiming Gao, Dustin W. Lynch, Usman Mahmood
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Radiation dose to patients in CT examinations (CTDIvol, DLP) is tracked in dose monitoring solutions. Some solutions push for automatically estimating patient organ doses based on exam images...
Authors: Liang-Hsin Chen, Li-Chien Wei
Affiliation: National Taiwan University Cancer Center
Abstract Preview: Purpose: For proton therapy treatment, it is essential to ensure that the treatments are delivered safely and accurately. Quality assurance (QA) programs of proton treatment system is needed and proto...
Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy
Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College
Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...