Search Submissions πŸ”Ž

Results for "multi distance": 34 found

A Method to Expedite Quality Assurance for Head and Neck Ctvs with Lymph Node Level Auto-Autocontouring and Identification

Authors: Beth M. Beadle, Adrian Celaya, Laurence Edward Court, David Fuentes, Anna Lee, Tze Yee Lim, Dragan Mirkovic, Amy Moreno, Raymond Mumme, Tucker J. Netherton, Callistus M. Nguyen, Jaganathan A Parameshwaran, Jack Phan, Carlos Sjogreen, Sara L. Thrower, Congjun Wang, He C. Wang, Xin Wang

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, Stanford University, The University of Texas MD Anderson Cancer Center, MD Anderson Cancer Center, MD Anderson, Rice University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Quality assurance of target volumes from radiotherapy clinical trials is a labor and resource intensive task. The purpose of this work is to quantify the accuracy of a tool that automatically...

A Multi-Agent Approach for Fully Automated Nephrometry Feature Extraction in CT

Authors: Matthew S Brown, Joshua Genender, John M. Hoffman, Gabriel Melendez-Corres, Muhammad W. Wahi-Anwar

Affiliation: David Geffen School of Medicine at UCLA, UCLA Department of Radiology

Abstract Preview: Purpose: Renal lesions are evaluated using scoring systems based on visual assessments and manual measurements. The purpose of this work is to develop a multi-agent system for automated anatomic landm...

AI Auto-Contouring for CT-Based High-Dose-Rate Interstitial Brachytherapy of Cervical Cancer: Implications for Organ-at-Risk (OAR) Contouring and Dosimetric Analysis

Authors: Indrin J. Chetty, Jing Cui, Mitchell Kamrava, Tiffany M. Phillips, Jennifer M. Steers, Brad Stiehl

Affiliation: Department of Radiation Oncology,Cedars-Sinai Medical Center, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Auto-contouring for HDR interstitial brachytherapy can be confounded by large deformation in anatomy and image quality. Here we evaluated the performance of an AI-based auto-contouring softwa...

An Assessment of the Potential Impact of the Elekta Unity’s 1.5T Magnetic Field upon the Performance of a Conventional Linac Installed in an Adjacent Vault: A Case Study

Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang

Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health

Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...

An Efficient Deep Learning Model with Multi-Scale Integration for Automated Pancreas Segmentation on MR Images

Authors: Jingyun Chen, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology

Abstract Preview: Purpose: To develop and evaluate the Scale-attention network (SANet) for automated pancreas segmentation on MR images.
Methods: To develop SANet, we extended the classic U-Net design with a dynamic...

Automatic Tumor Segmentation and Catheter Detection from MRI for Cervical Cancer Brachytherapy Using Uncertainty-Aware Dual Convolution-Transformer Unet

Authors: Majd Antaki, Rohini Bhatia, Gayoung Kim, Yosef Landman, Junghoon Lee, Akila N. Viswanathan

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Physics and Advanced Development Elekta

Abstract Preview: Purpose: Brachytherapy is a standard radiation therapy approach for cervical cancer, which directly delivers radiation source to the tumor using catheters. Treatment planning requires identification o...

Brachyplancheck: An Independent Monte Carlo Dose Calculation Tool for Brachytherapy Using Egs_Brachy

Authors: Amy Tien Yee Chang, Chi Wai Cheung, Tin Lok Chiu, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study introduces BrachyPlanCheck, an independent Monte Carlo (MC)-based dose calculation tool for 192Ir brachytherapy retrospective study or algorithm commissioning.
Methods: BrachyPl...

Characterization of Linear Energy Transfer Spectra in Mini Beam Spatially Fractionated Proton Therapy

Authors: Serdar Charyyev, Kaan Dere, Edgar Gelover, Mohammad Khurram Khan, Liyong Lin, Mark McDonald, Cristina Oancea, Alexander Stanforth, Sibo Tian, Suk Whan (Paul) Yoon, Mingyao Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Advacam

Abstract Preview: Purpose: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) utilizes physical collimators with apertures to generate minibeams, creating alternating regions of high-d...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Deep Learning Based Automatic Cerebrovascular Segmentation in Multi-Center TOF-MRA Datasets

Authors: Gayoung Kim, Junghoon Lee

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University

Abstract Preview: Purpose: 3D time-of-flight magnetic resonance angiography (TOF-MRA) is widely used for visualizing cerebrovascular structures. Accurate segmentation of cerebrovascular structures is critical for relia...

Deep Learning-Based Auto-Segmentation in Cervical High-Dose-Rate Brachytherapy with Clinical Considerations

Authors: Benjamin Haibe-Kains, Ruiyan Ni, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, University Health Network

Abstract Preview: Purpose: Accurate auto-segmentation for targets and organs-at-risk (OARs) using deep learning reduces the delineating time in radiotherapy. In high-dose-rate brachytherapy, specific clinical criteria ...

Development and Validation of Novel Two-Stage Vascular Segmentation Model for Interventional Angiography

Authors: Abid Khan, Chad Klochko, Michael J Kovalchick, Hyeok Jun Lee, Hani Nasr, Krishnan Shyamkumar, Kundan S Thind

Affiliation: Henry Ford Radiology, Wayne State University, Henry Ford Health, HFHS

Abstract Preview: Purpose: Automated vascular segmentation in interventional angiography is challenged by contrast kinetics, vessel variations, and 2D projections, limiting the effectiveness of single-model approaches....

Development of a Beam Profile Variation Observation Model for Intensity Modulated Radiotherapy

Authors: Kaile Li

Affiliation: Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...

Dosimetric Variations Induced By Inaccurate Collimator Angles in Single-Isocenter SRS Plan for Multi-Lesion Brain Metastases

Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue

Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...

Film-Based Method for Accurate Radiation Isocenter Determination in Linear Accelerators Using 3D Starshot

Authors: Robert A. Corns, Mohammad Kanber

Affiliation: East Carolina University, East Carolina University Brody School of Medicine

Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...

Fully Automated Review of Prostate Radiotherapy Treatment Plan Quality

Authors: Yasin Abdulkadir, John Charters, Melissa Ghafarian, James M. Lamb, Dishane Chand Luximon, Jack Neylon

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose:
Assessment of radiotherapy treatment quality in large-scale multi-institutional contexts remains an outstanding challenge. Retrospective human review of treatment plans is labor intensive ...

Gaze Angle Selection in Proton Therapy for Ocular Tumors with Machine Learning

Authors: Ling Chen, Alexei V. Trofimov, Yi Wang, Dufan Wu

Affiliation: Massachusetts General Hospital, MGH

Abstract Preview: Purpose:
Selecting gaze angles of the eye is an important part of set-up of proton therapy for ocular tumors, ensuring that the treatment beam could irradiate the tumor while maximally sparing impo...

Hydrated Electron Yield Under Electron Irradiation at Ultra-High Dose Rates with Varying Physical Beam Parameters

Authors: Xu Cao, Wesley S. Culberson, Aubrey Parks, Brian W Pogue, Matthew Reed, William Scott Thomas

Affiliation: University of Wisconsin: Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison, University of Wisconsin - Madison, UW-Madison

Abstract Preview: Purpose: Under Ultra-High Dose Rate (UHDR) irradiation, radical-radical interactions are likely enhanced due higher density production in time and space and this alters the cascade of reactions that s...

Impact of Six Degrees of Freedom Intrafraction Motion on Target Coverage for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Anupama Chundury, Hyejoo Kang, John C. Roeske, Iris A. Rusu

Affiliation: Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose: To quantify the dosimetric impact of six degrees of freedom (6DoF) intrafractional errors on gross tumor volume (GTV) and planning target volumes (PTV) for single-isocenter multi-target stere...

Improving the Robustness of AI-Based Detection and Segmentation for Brain Metastasis By Optimizing Loss Function and Multi-Dataset Training

Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte

Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine

Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...

Integrating SPECT and Compton Imaging for Multi-Energy Photon Reconstruction

Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu

Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Micro-Ultrasound Guided Focal Prostate Radiotherapy: Development and Testing of a Novel Device.

Authors: Kevin Barker, David Jeffrey Contella, Chandima Edirisinghe, Aaron Fenster, Douglas A Hoover, Elizabeth Huynh

Affiliation: Robarts Research Institute, University of Western Ontario, London Health Sciences Center, Department of Radiation Oncology, London Health Sciences Centre

Abstract Preview: Purpose: We aim to develop a system that integrates micro-ultrasound into focal prostate cancer radiotherapy. This requires developing a mechatronic stepper capable of performing motorized rotation of...

Modality-Agnostic Image Cascade (MAGIC) for Multi-Modality Cardiac Substructure Segmentation

Authors: Ming Dong, Carri K. Glide-Hurst, Qisheng He, Anudeep Kumar, Alex Singleton Kuo, Joshua Pan, Chase Ruff, Nicholas R. Summerfield

Affiliation: Department of Computer Science, Wayne State University, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Recent evidence highlights the importance of incorporating cardiac substructures (CS) into treatment planning for thoracic cancers, however current segmentation methods are limited to a singl...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Multi-Modality Artificial Intelligence for Involved-Site Radiation Therapy: Clinical Target Volume Delineation in High-Risk Pediatric Hodgkin Lymphoma

Authors: Tyler J Bradshaw, Sharon M Castellino, Steve Y Cho, David Hodgson, Bradford S Hoppe, Kara M Kelly, Andrea Lo, Sarah Milgrom, Xin Tie

Affiliation: Department of Radiation Oncology, University of Toronto, Department of Radiology, University of Wisconsin, University of Colorado Anschutz, Department of Medical Physics, University of Wisconsin, Department of Radiation Oncology, Mayo Clinic, Department of Radiation Oncology, BC Cancer, Vancouver Center, Department of Radiology, University of Wisconsin - Madison, Roswell Park Comprehensive Cancer Center, Emory University School of Medicine

Abstract Preview: Purpose: Clinical target volume (CTV) delineation for involved-site radiation therapy (ISRT) in Hodgkin lymphoma (HL) is time-consuming due to the need to analyze multi-time-point PET/CT scans co-regi...

Multi-Organ Segmentation of Pelvic Cone-Beam Computed Tomography (CBCT) with Transformer Models to Enhance Adaptive Radiotherapy for Prostate Cancer

Authors: Ming Chao, Thomas Chum, Tenzin Kunkyab, Yang Lei, Tian Liu, Richard G Stock, Hasan Wazir, Junyi Xia, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose:
This study aims to develop effective strategies for multi-organ segmentation of pelvic cone-beam computed tomography (CBCT) images based on transformer models to facilitate adaptive radiat...

Multi-Sid Optimization for 4 Pi Robotic Radiotherapy

Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...

NA-Unetr: A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Authors: Hassan Bagher-Ebadian, Ahmed I Ghanem, Joshua P. Kim, Chengyin Li, Rafi Ibn Sultan, Kundan S Thind, Dongxiao Zhu

Affiliation: Wayne State University, Department of Radiation Oncology, Henry Ford Health-Cancer, Detroit, MI and Alexandria Department of Clinical Oncology, Faculty of Medicine, Alexandria University, Henry Ford Health

Abstract Preview: Purpose: Accurate segmentation of the Left Anterior Descending (LAD) artery in free-breathing 3D treatment planning CT is crucial for radiotherapy but remains challenging due to its small size, comple...

Off- Axis Winston Lutz on C-Arm Linac Using in-House Phantom

Authors: Colton Baley, Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, Texas Oncology, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate the accuracy of off-axis winston lutz (WLT) for linac based stereotactic radiosurgery (SRS) treatments using in-house phantom.

Methods: Traditional WLT that uses cone and s...

Patient-Specific Imaging Modality Agnostic Virtual Digital Twins Modeling Temporally Varying Digestive Motion

Authors: James M. Balter, Lando S. Bosma, Jorge Tapias Gomez, Nishant Nadkarni, Mert R Sanbuncu, William Paul Segars, Ergys D. Subashi, Neelam Tyagi, Harini Veeraraghavan

Affiliation: University of Michigan, The University of Texas MD Anderson Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Cornell University, University Medical Center Utrecht, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Develop patient-specific virtual digital twin (VDT) cohorts modeling physically realistic spatio-temporal gastrointestinal (GI) organs (stomach and duodenum) digestive motion.
Methods: Pat...

Standardized Immobilization and Setup Procedure Improves Accuracy of Multi-Time Point SPECT/CT Image Registration for Radiopharmaceutical Therapy (RPT) Dosimetry

Authors: Bryan Bednarz, Laura Bennett, Abby E. Besemer, Tyler J Bradshaw, Steve Y Cho, John M. Floberg, Joseph Grudzinski, Elissa Khoudary, Michael J. Lawless

Affiliation: Department of Radiology, University of Wisconsin, University of Wisconsin-Madison Department of Medical Physics, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Voximetry, Inc, University of Pennsylvania, Department of Radiology, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: To assess the impact of using a standardized immobilization setup for multi-time-point SPECT/CT imaging on radiopharmaceutical therapy (RPT) dosimetry image registration.

Methods: Ten ...

Uncertainty-Guided Cross-Domain Adaptation for Unsupervised Medical Image Segmentation

Authors: Yunxiang Li, Weiguo Lu, Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Curating high-quality, labeled data for medical image segmentation can be challenging and costly, considering the existence of various image domains with differing modalities/protocols. Cr...