Search Submissions 🔎

Results for "multi leaf": 24 found

23na Magnetic Resonance Imaging k-Space Denoising

Authors: Lorenzo Arsini, Andrea Ciardiello, Fabio Massimo D'Amore, Stefano Giagu, Federico Giove, Carlo Mancini-Terracciano, Cecilia Voena

Affiliation: Istituto Superiore di Sanità, Sapienza University of Rome, Università Sapienza Roma, Magnetic Resonance for Brain Investigation Laboratory, Museo Storico della Fisica e Centro di Studi e Ricerche Enrico Fermi

Abstract Preview: Purpose: To leverage newly developed heteronuclear magnetic resonance imaging (MRI) techniques, particularly sodium (23Na) imaging, for identifying potential biomarkers of Alzheimer's disease—such as ...

A Dual Energy CT-Guided Intelligent Radiation Therapy Platform

Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

Brain Tumor Segmentation from Multi-Parametric MRI with Integrated Evidential Uncertainty Estimation

Authors: Sahaja Acharya, Matthew Ladra, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University

Abstract Preview: Purpose: Multi-parametric MRI (mpMRI) is widely used for deep learning (DL)-based automatic segmentation of brain tumors. While multi-contrast images concatenated as channels are typically input to ne...

Centralizing Resources with a Microsoft-Based Wiki Platform: Enhancing Collaboration and Efficiency in Radiation Oncology

Authors: Simon Brundage, Jiajin Fan, Ulrich Langner, Qiongge Li, Jian Liu, Wei Nie, Edwin Quashie, Xiaofeng Zhu

Affiliation: Brown University Health, Hofstra University Medical Physics Program, Inova Hospital, Inova Schar Cancer Institute, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Managing departmental policies, clinical protocols, QA procedures, workflows, and troubleshooting documentation is critical in radiation oncology. A Microsoft-based wiki platform was devel...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Development of a Beam Profile Variation Observation Model for Intensity Modulated Radiotherapy

Authors: Kaile Li

Affiliation: Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...

Development of an Ultrafast MR Technique to Detect Linac Radiation Pulses for Biological Imaging on a Clinical 0.35T MR-Linac

Authors: Pierre Gardair, Johnathan E Leeman, Claire Keun Sun Park, Atchar Sudhyadhom

Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School, Harvard Medical School

Abstract Preview: Purpose: Dose is a poor surrogate for radiobiological damage but no in vivo technology exists to directly measure damage such as DNA strand breaks and free radical generation (FRG). Recent advances in...

Diffusion-Based PET Image Enhancement in Bgrt

Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie

Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The RefleXion® X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...

Dosimetric Impact of Catheter Length Changes in HDR Brachytherapy for Accelerated Partial Breast Irradiation

Authors: Dylan Richeson, Dorin A. Todor

Affiliation: Inova Schar Cancer Institute, Virginia Commonwealth University

Abstract Preview: Purpose: High dose-rate (HDR) brachytherapy is prone to errors that can lead to incorrect dose delivery and potential medical events. One common issue is applicator length discrepancies, either due to...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Evaluating Target Isocenter Accuracy in Off-Isocenter Treatments Using an Extended Winston-Lutz Test

Authors: Maria de la Luz De Ornelas, Yunze Yang

Affiliation: University of Miami

Abstract Preview: Purpose:
An extended Winston-Lutz test (EWL), also known as off-axis Winston-Lutz, was performed to assess the linear accelerator’s (linac) deviations at isocenter and five off-iso targets. The imp...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Investigation of the Impact of Dlg Changes on Plan Quality and Patient Specific QA

Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold

Affiliation: Scripps Cancer Center

Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...

Monte Carlo Simulation of Surface Radiation Dose for Cherenkov Imaging: Comparison with Commissioning Data for Truebeam and Halcyon

Authors: Hongjing Sun, Weibing Yang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to compare the commissioning results of TrueBeam and Halcyon linear accelerators with Monte Carlo (MC) simulations conducted using TOPAS. The ultimate goal is to leverage MC s...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Precise Measurement of Leaf Open Time in Tomotherapy Using Advanced Plastic Scintillators

Authors: Marcos Feijoo, Mamoru Ichiki, Tatsuya Maeda, Tatsuhiro Makino, Tomonori Megumi, Tadashi Nakabayashi, Yukino Nakata, Shuichi Ozawa, Daishi Takayama

Affiliation: Hiroshima High-Precision Radiotherapy Cancer Center, Blue Physics LLC, Imamura General Hospital, Accuray Inc.

Abstract Preview: Purpose: This study aims to accurately measure the leaf open time (LOT) of the multi-leaf collimator (MLC) in tomotherapy using an advanced plastic scintillator detector (PSD) with high time resolutio...

Real-Time 3D Dose Verification for MR-Guided Online Adaptive Radiotherapy (ART) Via Geometry-Encoded Deep Learning Framework

Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Fast dose verification is essential for the safety and efficiency of MR-guided adaptive radiotherapy (ART) as patients anxiously waiting on the treatment couch. Conventional tools often requi...

Reinforcement Learning Based Machine Parameter Optimization for Two-Arc Prostate VMAT Planning

Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...