Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...
Authors: Dale Black, David Clymer, Huanjun Ding, Hamidreza Khodajou Chokami, Sabee Molloi, Christine Vy Nguyen, Tim Sananikone, Alireza Shojazadeh, Randy Wang
Affiliation: Department of Radiological Sciences, University of California, University of California, Department of Radiological Sciences, University of California, Irvine, Department of Radiological Sciences, University of California, Irvine
Abstract Preview: Purpose: We present a novel multi-material decomposition (MMD) algorithm for accurate quantification of material concentration in reconstructed dual-energy CT images. This method addresses limitations...
Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...
Authors: Amir Abdollahi, Oliver Jรคkel, Maxmillian Knoll, Rakshana Murugan, Adithya Raman, Patrick Salome
Affiliation: UKHD & DKFZ, Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), German Cancer Research Centre(DKFZ), DKFZ, MGH
Abstract Preview: Purpose:
Missing MRI sequences, due to technical issues in data handling or clinical constraints like contrast agent intolerance, limit the use of medical imaging datasets in computational analysis...
Authors: Anzi Zhao
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: This study investigates the utility of Dual-Energy Computed Tomography (DECT) material decomposition in resolving Magnetic Resonance Imaging (MRI) safety concerns for patients with unidentifi...
Authors: Zhiqiang Chen, Hewei Gao, Li Zhang, Guoxi Zhu
Affiliation: Tsinghua University
Abstract Preview: Purpose: Spectral cone-beam CT has better performance in material identification and quantitative analysis compared to single-energy cone-beam CT. However, X-ray scattering introduces significant scat...
Authors: Izabella L. Barreto, Aroon Pressram
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: Our clinical dual energy CT (DECT) head protocol reconstructs iodine-suppressed virtual non-contrast (VNC) images using the vendor-recommended slope for material discrimination. However, this...
Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago
Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...
Authors: Carlos E. Cardenas, Udbhav S. Ram, Marcin Wierzbicki
Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham, Juravinski Cancer Centre
Abstract Preview: Purpose:
This study aims to systematically evaluate the dosimetric properties and delivery efficiency of 6X-FFF and 10X-FFF beams for lung SBRT on the Varian TrueBeam STx using the Eclipse TPS 16.1...
Authors: Yi-Fang Wang, Yading Yuan
Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...
Authors: Yufeng Cao, Luigi Marchionni, William Silva Mendes, Cem Onal, Lei Ren, Amit Sawant, Nicole L Simone, Philip Sutera, Phuoc Tran
Affiliation: University of Maryland School of Medicine, 9Department of Radiation Oncology, Thomas Jefferson University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, University of Maryland, Baltimore, Baskent University Faculty of Medicine, Department of Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, 8Department of Pathology and Laboratory Medicine, Weill Cornell Medicine
Abstract Preview: Purpose: This study aims to predict 2-yr Metastasis-free survival (MFS) for oligometastatic castration-sensitive prostate cancer (omCSPC) patients treated by metastasis-directed therapy (MDT) by devel...
Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe
Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences โMario Serioโ, University of Florence
Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...
Authors: Giavanna Luisa Jadick, Patrick J La Riviere
Affiliation: University of Chicago
Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...
Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Womenโs Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute
Abstract Preview: Purpose: Multi-layer flat-panel imagers can improve for clinical image-guided radiotherapy applications, including the enhanced visualization of soft tissue and a reduction in image artifacts. Each im...
Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Maria F. Chan, Yabo Fu, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Lee, Tianfang Li, Xiang Li, Jean M. Moran
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Iodine maps derived from Dual-Energy CT (DECT) provide critical biological information for radiotherapy treatment planning, but clinical iodine maps often mistakenly include bones due to insu...
Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...