Search Submissions 🔎

Results for "multiple different": 56 found

A Clinical Evaluation of Two Commercially Available Deep-Learning Algorithms for Automated Organs at Risk Contouring

Authors: Steven DiBiase, Gurtej S. Gill, Haohua Billy Huang, Nicholas J. Lavini, Luxshan Shanmugarajah, Salar Souri, Samantha Wong

Affiliation: Stony Brook University, Northwell Health, Cornell University, NewYork-Presbyterian, New York-Presbyterian

Abstract Preview: Purpose: Clinical applications of deep learning-based algorithms have come to the radiation oncology field as organ at risk (OAR) auto contouring programs. We evaluated two of these algorithms’ (Radfo...

A Deformable Registration-Based Pipeline for the Characterisation of Respiratory Motion from 2D Lung Cine MRI

Authors: Michael W. Kissick, Chung Tin Lo, Jamie R McClelland, Niek Schreuder, Tracy Underwood

Affiliation: Hawkes Institute, University College London, Leo Cancer Care

Abstract Preview: Purpose: The emerging field of upright radiotherapy raises the question of how respiratory motion differs between upright and supine treatment postures. Therefore, we have developed a versatile pipeli...

A Dosimetric Analysis of Lu-177-Based Radiopharmaceutical Therapy for Optimizing Therapeutic Ratio

Authors: Travis James McCaw, Ravi Patel, Abdelhamid Saoudi, Joseph Shields

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, University of Pittsburgh Medical Center, UPMC

Abstract Preview: Purpose: The current treatment approach for Lu-177-based radiopharmaceutical therapy involves multiple administrations, each delivering a constant activity of 200 mCi. This study evaluates whether the...

A Multi-Institutional Survey of Current Therapeutic Medical Physics Residents’ Satisfaction and Interview Experience

Authors: Seifallah Emam, Gilberto Gonzalez, Anna E. Rodrigues

Affiliation: Duke University, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose:
To survey current therapeutic medical physics residents on 1) the accuracy with which residency programs were represented during interviews, 2) factors that most strongly impacted resident...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

A Study of Large Model Alignment Techniques for MRI Images of Small Sample Meningioma

Authors: Xiangli Cui, Man Hu, Wanli Huo, Da Yao, Jianguang Zhang, Yingying Zhang, Shanyang Zhao

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Departments of Radiation Oncology, Zibo Wanjie Cancer Hospital, Department of Oncology, Xiangya Hospital, Central South University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University, Shandong Academy of Medical Sciences

Abstract Preview: Purpose:
To study the fine-tuning strategy of pre-trained AI image generation model to adapt to the generation of small sample meningioma MRI images, explore its impact on observer performance, and...

AI-Assisted 3D Microscale Mesh Models of Human Lungs from Iodine-Stained Serial-Sectioned Histology Images and Their Dosimetry Applications

Authors: John P. Aris, Wesley E. Bolch, Robert Joseph Dawson, Bonnie N. C. President, Yitian Wang

Affiliation: Johns Hopkins University, University of Florida

Abstract Preview: Purpose: Generation of a mesh-based microscale lung model is essential for accurate dosimetry analysis. Lungs exchange air with the environment and may be exposed to alpha-particle-emitting radionucli...

Advanced Modeling of Singlet Oxygen Distribution in Pleural Cavity Photodynamic Therapy Using Validated Geometric Standardization

Authors: Hongjing Sun, Timothy C. Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to develop a model of singlet oxygen distribution in pleural photodynamic therapy (PDT) by combining standardized anatomical coordinates with CT-validated geometry reconstruct...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

An Accelerated Scatter Estimation for Spectral CBCT Based on Linear Boltzmann Transport Equation

Authors: Zhiqiang Chen, Hewei Gao, Li Zhang, Guoxi Zhu

Affiliation: Tsinghua University

Abstract Preview: Purpose: Spectral cone-beam CT has better performance in material identification and quantitative analysis compared to single-energy cone-beam CT. However, X-ray scattering introduces significant scat...

An Efficient Deep Learning Model with Multi-Scale Integration for Automated Pancreas Segmentation on MR Images

Authors: Jingyun Chen, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology

Abstract Preview: Purpose: To develop and evaluate the Scale-attention network (SANet) for automated pancreas segmentation on MR images.
Methods: To develop SANet, we extended the classic U-Net design with a dynamic...

Application of Team Science in Medical Physics Research for Undergraduate Students

Authors: Ashley Cetnar

Affiliation: The Ohio State University - James Cancer Hospital

Abstract Preview: Purpose: Undergraduate students are eager to learn more about potential career opportunities. While many physics majors are aware of research opportunities within the physics department, students may ...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Attention-Based Multiple Instance Learning of Head and Neck Cancer Grading on Digital Pathology Using Vision-Language Foundational Models

Authors: Kyle J. Lafata, Xiang Li, Megan K. Russ, Zion Sheng

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: To adapt Vision-Language Foundational Models (VLFM) to perform HNSCC tumor grading on H&E whole slide images (WSI) via attention-based multiple instance learning (ABMIL).
Methods: We utili...

Automatic 4D Lung PET-CT Segmentation Using Hybrid Deep Neural Network

Authors: Hongyi Jiang, Fang-Fang Yin

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. TomĂŠ

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Confidence in a Tattoo-Less Transition

Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak

Affiliation: Christiana Care

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...

Convergence Speed Advantages of a Machine Learning Assisted Framework in IMRT Fluence Map Optimization – a Comparison Study Using Multiple Convergence Criteria

Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang

Affiliation: Duke University Medical Center

Abstract Preview: Purpose: Convergence speed is crucial for an optimizer. Faster convergence leads to better solutions with fewer iterations and less time. Recently, a machine learning (ML)-assisted framework employing...

Deep Learning Aided Oropharyngeal Cancer Autoplanning

Authors: Mark Bowers, Gabriel Carrizo, Jimmy Caudell, Vladimir Feygelman, Kevin Greco, Christian Hahn, Jihye Koo, Kujtim Latifi, Fredrik Lofman, Jacopo Parvizi, Muqeem Qayyum, Caleb Sawyer

Affiliation: RaySearch Laboratories, Moffitt Cancer Center

Abstract Preview: Purpose: Head and neck (H&N) radiotherapy planning is complex, with multiple competing objectives. We endeavored to improve efficiency of planning by developing a deep learning (DL) model trained to p...

Denoising Diffusion-Weighted Images of Rectal Cancer Acquired on a 0.35 T Magnetic Resonance Imaging-Guided Linear Accelerator Using Singular Value Decomposition

Authors: Jacqueline M. Andreozzi, Tess Armstrong, Shiva Bhandari, John M Bryant, Jessica M Frakes, David J. Gladstone, Sarah E Hoffe, Kujtim Latifi, Arash Naghavi, Steven Nichols, Ibrahim M. Oraiqat, Russell Palm, Gage H. Redler, Stephen A Rosenberg, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Thayer School of Engineering, Dartmouth College, Department of Radiation Oncology, Ohio State University, Moffitt Cancer Center, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose: The MR-linac provides unique opportunities for integrating advanced imaging into radiotherapy workflows, but the lower sensitivity of systems like the 0.35T model can pose challenges for diff...

Design and Testing of a Portable Microwave Scanner for Imaging Soft Tissue and Tumors in Cancer Patients

Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed

Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...

Developing 3D-Printed Synthetic Vertebrae with Realistic Surgical Haptic Feedback and Biomechanical Properties

Authors: Chloe Duncan, Andrew Kanawati, Peter Malek, Tess Reynolds

Affiliation: University of Sydney, Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: Pedicle screw fixation, a standard spinal surgery procedure, has high misplacement rates (~40%) which decrease with surgeon experience. However, opportunities for surgical rehearsal, training...

Development and Evaluation of Fat Fraction Reference Materials for Magnetic Resonance Imaging

Authors: Hyo-Min Cho, Cheolpyo Hong, Changwoo Lee, Sunyoung Lee

Affiliation: Daegu Catholic University, Korea Research Institute of Standards and Science (KRISS), Korea Research Institute of Standards and Science

Abstract Preview: Purpose: With the increasing prevalence of metabolic syndrome, the importance of diagnosing obesity and fatty liver diseases has grown significantly. As a result, there is a rising demand for non-inva...

Development of Cross-Platform Application for Radiation Contamination Assessment

Authors: Wesley E. Bolch, Lotem Buchbinder Shadur, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Shaheen Dewji, John Francis, Emmanual Mate-Kole, Wyatt Smither, Yitian Wang

Affiliation: Georgia Tech, University of Florida, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: Develop a software application capable of assessing the radiation contamination of military service members and members of the general public for fast, on-site radiological triage. The softwa...

Dose Distribution Analysis for Different Geometries of a Multiple-X-Ray Source Array (MXA) CT Scanner

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A Multiple-X-ray Source Array (MXA) for CT (MXA-CT) is under development to mitigate cone beam artifacts in axial CT scans using wide collimation. The purpose of this study is to assess the i...

Enhanced 3D Volumetric Denoising for Low-Dose CT Images Using Hformer

Authors: Edward Robert Criscuolo, Chenlu Qin, Deshan Yang, Zhendong Zhang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose:
Low-dose CT (LDCT) imaging minimizes radiation exposure but introduces significant noise, compromising image quality. While deep learning-based denoising models such as HFormer achieve sta...

Evaluating the Impact of Reconstruction Algorithm on Wide-Angle Digital Breast Tomosynthesis System Optimization for Microcalcification Detection

Authors: Xiaoyu Duan, Xinyu Hu, Runqiu Li, Xiang Li

Affiliation: Dukekunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Accurate detection of small-sized microcalcifications (ÎźCalcs) (< 500 Âľm) is critical for early breast cancer diagnosis, requiring optimal imaging systems and reconstruction algorithms. Ho...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

Evolution of Log File-Based Patient-Specific QA across Multiple Linac Replacements

Authors: Gweneth Andersen, Colleen M. Foote, David (Bo) McClatchy, Hannah McFarland

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To quantify the impact of MLC model differences and LINAC age on treatment plan evaluation by log file-based patient-specific QA (PSQA) through the lifetime of the machines.
Methods: 3D ga...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Fine-Tuning AI-Based Generative Models for Small-Sample Glioma MRI Generation.

Authors: Xiangli Cui, Chunyan Fu, Man Hu, Wanli Huo, Jingyu Liu, Jianguang Zhang, Yingying Zhang, Shanyang Zhao

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Departments of Radiation Oncology, Zibo Wanjie Cancer Hospital, Key Laboratory of Electromagnetic Wave Information Technology and Metrology of Zhejiang Province, College of Information Engineering, China Jiliang University, Department of Oncology, Xiangya Hospital, Central South University, College of Information Engineering, China Jiliang University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University, Shandong Academy of Medical Sciences

Abstract Preview: Purpose: To quantify the impact of fine-tuning strategies for pre-trained AI image generation models on glioma MRI image quality and observer performance, and to determine the optimal fine-tuning conf...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero LÜnnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität Mßnchen (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) Mßnchen, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Inconsistencies in Methods for CMS Size-Adjusted Dose Measure

Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The upcoming CMS regulation, titled “Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults”, employs two measures, size-adjusted DLP (SAD) and...

International Survey of Electronic Medical Device Management in Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Electronic medical devices (EMDs) must be carefully managed in radiation oncology to prevent radiation-induced device malfunction. Only one EMD, pacemaker/defibrillator, has a recommended pro...

Multi-Institutional Analysis of CT Dose Index Variability and Radiomics Features

Authors: Caroline Chung, Michael Knopp, Stephen F. Kry, Hunter S. Mehrens, John Rong

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, University of Cincinnati

Abstract Preview: Purpose: To evaluate the variability of CT dose index (CTDIvol) and radiomics features across a large cohort of radiotherapy simulation CT scans from multiple institutions.
Methods: Three IROC phan...

Multi-Institutional Evaluation of Radiographic Automatic Exposure Control Performance Testing: Methodology, Outcomes, and Failure Rates

Authors: Caroline Cheney, Nicole M. Lafata, Zaiyang Long, Dustin W. Lynch, Erin B. Macdonald, Andy Madore, Douglas E. Pfeiffer, Colin Schaeffer, Alexander W. Scott

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, UVA Health, Duke University Health System, Mayo Clinic, Henry Ford Health, Boulder Community Health, Varian, Cedars-Sinai Medical Center

Abstract Preview: Purpose: This work evaluates the significance of performing established radiography automatic exposure control (AEC) tests by comparing testing methodology, outcomes, and failure rates across multiple...

Multi-Mechanism CNN and Long Short-Term Memory Fusion Model for Improved CT-Based Thyroid Cancer Diagnosis

Authors: Yunfei Dong, Dongyang Guo, Jiongli Pan, Tao Peng, Caiyin Tang, Zhenyu Yang, Fang-Fang Yin, Lei Zhang, Tianyi Zhang, Yaogong Zhang

Affiliation: Duke Kunshan University, Department of Radiology, Taizhou People’s Hospital Affiliated to Nanjing Medical University, School of Future Science and Engineering, Soochow University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: This study aims to improve the accuracy of CT-based diagnosis of thyroid cancer by developing a hybrid model that integrates Convolutional Neural Networks (CNNs) with Long Short-Term Memory (...

Multi-Sid Optimization for 4 Pi Robotic Radiotherapy

Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...

Multi-Variat, Multi-Model, and Multi-Patient: From Pure Feasibility to Generalizability in Machine Learning Outcome Prediction Model-Based Treatment Plan Optimization

Authors: Martin Frank, Oliver Jäkel, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose: Machine learning (ML) models on normal tissue complication and tumor control probability ((N)TCP) exploiting e.g. dosiomic and radiomic features are playing an increasingly important role in ...

Neutron Dose Measurements with Multiple Dosimetry Techniques for Fetal Dose Estimation

Authors: Ahmet S. Ayan, Estelle Batin, Austin M. Faught, Peter E. Klages, Eunsin Lee, Collin Nappi, Mina Okello, Meghana Ramani, Zachary X. Richards, Parisa Sadeghi

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: Neutron doses are not modelled in proton treatment planning systems, so measurements were taken with two independent dosimeter types to quantify representative neutron fetal doses in pencil b...

Patterns of Nanoparticle Uptake for Patients with Multiple Brain Metastases: Similarities and Differences to Standard Gbca

Authors: Stephanie Bennett, Ross I. Berbeco, Ning Jin, Sonal Josan, Justin Michael Sheetz, Atchar Sudhyadhom

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Massachusetts - Lowell, Siemens Healthineers, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women's Hospital

Abstract Preview: Purpose: AGuIX, a Gadolinium-based theranostic radiosensitizing nanoparticle, is currently under clinical evaluation in Europe and the US. Using patients from the double-blinded NanoBrainMets trial, u...

Phantom-Based Dosimetric Comparison of Multiple CT Metal Artifact Reduction Algorithms for Head-and-Neck Radiotherapy

Authors: Loren Bell, Charles S Cathcart, Brett William Eckroate, Harold Y Hu, Joshua Kilian-Meneghin, Ke Nie, Fredrick Warburton, Zhenyu Xiong, Keying (Karen) Xu, Ning J. Yue, Yin Zhang, Lili Zhou

Affiliation: RWJBarnabas Health, Basis Scottsdale, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: This study compares the dosimetric impact of multiple metal artifact reduction (MAR) algorithms from different CT simulator vendors using an anthropomorphic head phantom for head-and-neck (H/...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Python-Based Patient Coaching System for Gated Treatment Delivery

Authors: Usha Robins Abraham, Monique Lockhart Chisem, Alonso N. Gutierrez, Janos Juhasz, Michael Leyva, Carlos M. Rivera, Ranjini P. Tolakanahalli, Vanessa Vega Fleites

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health

Abstract Preview: Purpose:
Accurate breath hold (BH) gated treatments rely heavily on patient cooperation. Maintaining consistent breath-hold levels can be challenging for patients. Surface image guidance (SGRT) is ...

Radiological Assessment of Radiochromic Film Models EBT3 and EBT4 in Proton Beams

Authors: Kuan Ling Chen, Jiajin Fan, Rao Khan, Robabeh Rahimi

Affiliation: University of Maryland, Inova Schar Cancer Institute, Howard University

Abstract Preview: Purpose: This study evaluates the dose response, energy dependency, sensitivity, reproducibility, temporal response, and LET dependency along and in the plane perpendicular to a clinical proton beam f...

Real-Time 3D Visualization of Electric Field with Electroacoustic Tomography

Authors: Jadon O Buller, Yankun Lang, Liangzhong Xiang, Andrea Paulina Yanez

Affiliation: University of Maryland School of Medicine, University of California, Irvine

Abstract Preview: Purpose: With the widespread adoption of electroporation, there is growing interest in deep-tissue electric field monitoring. Electroporation therapy ablates target regions by generating electric fiel...

Surface Dose Distribution Analysis Using Cherenkov Imaging for Total Skin Electron Therapy (TSET) with Scintillator and Osld Validation

Authors: Baozhu Lu, Hongjing Sun, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to validate the feasibility of using Cherenkov imaging for surface dose distribution measurement during Total Skin Electron Therapy (TSET) by developing a perspective-correcte...

The Effect of Radiotherapy Structure Shape Features on the Accuracy of Their Digital Representation and Manipulation

Authors: Annie Cooney, Kenneth L. Homann, Somayeh Taghizadehghahremanloo, Adam D. Yock, Hong Zhang

Affiliation: Assistant Professor, Vanderbilt University Medical Center

Abstract Preview: Purpose:
Digital radiotherapy data has been standardized using the DICOM format. However, different radiotherapy software environments interpret identical data differently due to inherent software ...

Time-Efficient Photon Plan Checks with Esapi-Based Software

Authors: Kevin Peter Risolo

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: To quantify the improved efficiency of checking patient treatment plan MU by utilizing RadFormation’s ClearCalc script-based program.
Methods: A total of 58 patients planned for treatment ...

Topas-Nbio – Status and Outlook after a Decade of Developments

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Kathryn D Held, Nicolas Henthorn, Jay LaVerne, Thongchai Masilela, Stephen J. McMahon, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin, Michael Taylor, John Warmenhoven

Affiliation: Massachusetts General Hospital, Queen's University Belfast, Massachusetts General Hospital and Harvard Medical School, University of California San Francisco, University of Manchester, Notre Dame University

Abstract Preview: Purpose: TOPAS-nBio brings a cutting-edge Monte Carlo (MC) simulation framework to the research community to test hypotheses of radiation effects at the nanometer/cell scale. Here, we present the deve...

Universal Anatomical Mapping and Patient-Specific Prior Implicit Neural Representation for MRI Super-Resolution

Authors: Jie Deng, Yunxiang Li, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Magnetic Resonance Imaging (MRI) has exceptional soft tissue contrast and an essential role in radiotherapy. The introduction of clinical MR-LINACs has enabled adaptive radiotherapy (ART) usi...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Validation of a Pharmacokinetic Model for Dosimetry in Nuclear Medicine

Authors: Farhad Jafari, Brandon Hai Nguyen

Affiliation: Department of Radiation Oncology, University of Minnesota Medical School, Department of Radiology, University of Minnesota

Abstract Preview: Purpose: To validate a bottom-up approach to dosimetry in nuclear medicine.

Methods: A pharmacokinetic model is developed to represent the flow of activity between different compartments of the...

Variations in Automatic Dose Response Curves across Fluoroscope Types and Manufacturers for Abdominal Imaging

Authors: Hadley Anna DeBrosse, Edward J. Stafford, Kevin A. Wunderle

Affiliation: Ohio State University, The Ohio State University

Abstract Preview: Purpose: To investigate automatic dose response curves from fluoroscopes across multiple manufacturers for an abdominal imaging protocol.
Methods: ADRC response for multiple fluoroscopes were evalu...