Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng
Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...
Authors: Alonso N. Gutierrez, Daniel E. Hyer, Blake R. Smith
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Iowa Health Care, University of Iowa
Abstract Preview: Purpose: To perform a feasibility study of optimizing and producing a compact range compensator to deliver single-energy pencil beam scanning (PBS) proton arc therapy treatments. Omitting energy chang...
Authors: Ruiyan Du, Mingzhu Li, Ying Li, Wei Liu, Shihuan Qin, Yiming Ren, Biao Tu, Hui Xu, Lian Zhang, Xiao Zhang, Zengren Zhao
Affiliation: Department of General Surgery, Hebei Key Laboratory of Colorectal Cancer Precision Diagnosis and Treatment, The First Hospital of Hebei Medical University, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Mayo Clinic, Department of Oncology, The First Hospital of Hebei Medical University
Abstract Preview: Purpose: Fiducial tracking is widely used in CyberKnife to dynamically guide the gantry for moving target like liver cancer stereotactic body radiation therapy (SBRT). This study developed a robust fr...
Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...
Authors: Peter Balogh, Wesley E. Bolch, Mir Md Nasim Hossain, Nien-Wen Hu, Walter Murfee, Wyatt Smither, Julia D. Withrow
Affiliation: New Jersey Institute of Technology, University of Florida
Abstract Preview: Purpose: To develop 3D computational, tissue-representative models incorporating physiologically relevant microvascular network patterns for calculating local alpha particle and electron dosimetry eff...
Authors: Shahed Badiyan, Tsuicheng D. Chiu, Viktor M. Iakovenko, Steve Jiang, Christopher Kabat, Mu-Han Lin, Roberto Pellegrini, Arnold Pompos, Edoardo Salmeri, David Sher, Sruthi Sivabhaskar, Justin D. Visak
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Global Clinical Science, Elekta AB, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Adaptive treatment planning requires robust strategies to enable streamlined on-couch processes, creating a significant barrier for planners transitioning from conventional to adaptive planni...
Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...
Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...
Authors: Zixu Guan, Takahiro Iwai, Takashi Mizowaki, Mitsuhiro Nakamura, Michio Yoshimura
Affiliation: Kyoto University, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose:
The goal of this study is to develop a fully automated treatment planning approach for VMAT in pancreatic cancer that can convert patient anatomy into LINAC machine parameters. In this wor...
Authors: Jacob Gooslin, Ellis Lee Johnson, Damodar Pokhrel
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: HyperArc radiosurgery permits treatment of multiple brain lesions using a single-isocenter improving treatment planning efficiency and workflow. A key stereotactic planning aspect is an indep...
Authors: Alyssa Gadsby, William J. Godwin, Jennifer L. Harper, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan
Affiliation: Medical University of South Carolina
Abstract Preview: Purpose: Multi-Criteria Optimization (MCO) theoretically allows for increased dose control during optimization. This study is the first to compare standard optimization (SO) and MCO for accelerated pa...
Authors: Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Rojano Kashani, Kyle O'Carroll, Gisele Castro Pereira, Christian Erik Petersen, Alex T. Price, Meiying Xing, Reine abou Zeidane
Affiliation: university hospital, University Hospitals Seidman Cancer Center
Abstract Preview: Purpose:
Experimental data have shown the inconsistent monitor unit and target coverage in Ethos 1.1. This can lead to inaccurate dose delivery, compromising patient safety and treatment outcomes. ...
Authors: Prasanna Alluri, Mona Arbab, Xingzhe Li, Chang-Shiun Lin, Mu-han Lin, David D.M. Parsons, Asal Rahimi, Justin D. Visak, Narine Wandrey
Affiliation: UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX
Abstract Preview: Purpose: Intelligence-Optimization-Engine (IOE) v1.0 relied heavily on planner expertise and patient-specific IMRT beam arrangements, requiring frequent revisions. While VMAT workflows offered potenti...
Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao
Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...
Authors: Pat Esposito, Ashley Klein, Carmine Verna, Ling Zhuang
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: To evaluate dosimetric parameters and treatment delivery efficiency between volumetric modulated arc therapy (VMAT) and hybrid dynamic conformal arc (HDCA) on SRS and SBRT planning through st...
Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang
Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital
Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...
Authors: Yijian Cao, Jenghwa Chang, Lyu Huang
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose: This study evaluates the treatment delivery efficiency and workflow of two advanced linear accelerator systems—Varian’s TrueBeam (C-arm) and Halcyon (O-ring)—for prostate Stereotactic Body Ra...
Authors: David Chighvinadze, Indra J. Das, Jeremy D. Donaghue, Kevin Stephans, Gregory Videtic, Sugandima Weragoda, Ping Xia
Affiliation: Cleveland Clinic, Cleveland Clinic Sandusky, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Cleveland Clinic Fairview
Abstract Preview: Purpose:: Evaluate the impact of lung density variations on plan quality and delivery parameters in lung SBRT Plans.
Methods: For a hypothetical case with a real patient anatomy, three GTVs with vo...
Authors: Richard Dortch, Thammathida Ketsiri, Zhiqiang Li, Shiv P. Srivastava
Affiliation: Barrow Neurological Institute, Dignity Health Cancer Institute, St. Joseph's Hospital & Medical Center
Abstract Preview: Purpose: Imaging the spinal cord post-surgery is challenging due to metal surgical implants, which induce signal loss and geometric distortions. Together, this hinders the visualization of the spinal ...
Authors: Shahed Badiyan, Chien-Yi Liao, Mu-Han Lin, Dan Nguyen, Justin D. Visak, Hui Ju Wang, Brien Timothy Washington, Kenneth Westover, Yuanyuan Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Knowledge-based planning (KBP) plays a crucial role in improving treatment plans by leveraging previous clinical data to guide new cases. KBP is applied to the Ethos 2.0 Intelligent Optimizat...
Authors: Bin Cai, Andrew R. Godley, Brian A. Hrycushko, Heejung Kim, Mu-han Lin, David D.M. Parsons, Justin D. Visak, Da Wang, Tingliang Zhuang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: The standard radiation therapy workflow requires CT-simulation and planning, whether for initial treatments or re-planning due to significant anatomical changes. IPART instead uses one patien...
Authors: Yukio Fujita, Syoma Ide, Fumiki Ito, Kei Ito, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki, Riku Watanabe
Affiliation: Komazawa University Graduate School, Komazawa University, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital
Abstract Preview: Purpose: Spine stereotactic body radiotherapy (SBRT) demands high precision due to the target's proximity to the spinal cord and steep dose gradients, which complicate treatment planning. Consequently...
Authors: Liu Hong, Zhong Su
Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...
Authors: Geoffrey D. Clarke, Laura A. Cox, Alexander J Moody, Peter W Nathanielsz, Bowen Yang
Affiliation: Wake Forest University School of Medicine, University of Texas Health Science Center at San Antonio, Texas Biomedical Research Institute
Abstract Preview: Purpose:
Recent studies show diagnostic value of myocardial strain analysis for left ventricular (LV) function using cardiac magnetic resonance imaging (CMR). RV function analysis is more challengi...
Authors: Shahed Badiyan, Chien-Yi Liao, Mu-Han Lin, David D.M. Parsons, Justin D. Visak, Brien Timothy Washington, Kenneth Westover, Yuanyuan Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX
Abstract Preview: Purpose: Adaptive radiotherapy (ART) programs are resource-intensive due to their technical complexities, requiring highly skilled planners. Leveraging integrated automated treatment planning system (...
Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang
Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center
Abstract Preview: Purpose: Using mixed fractionation schemes is a common technique in treating CNS lesions. This article describes an innovative plan-and-split approach for more efficient planning on the ZAP-X and thus...
Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang
Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University
Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...
Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cell microstructure information is critical for radiotherapy response assessment. Diffusion MRI (dMRI) offers great potential in deriving cell parameters. Yet parameters estimated in existing...
Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels
Affiliation: Varian Medical Systems
Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...
Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...
Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...
Authors: Avinash Mudireddy, Nathan Shaffer, Joel J. St-Aubin
Affiliation: University of Iowa
Abstract Preview: Purpose: This work demonstrates preliminary results in training a reinforcement learning (RL) network to perform VMAT machine parameter optimization.
Methods: We implemented a policy gradient RL al...
Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray
Affiliation: University of California San Diego
Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...
Authors: Caiden Atienza, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin
Affiliation: Iowa Health Care, University of Iowa
Abstract Preview: Purpose: Pinnacle3 TPS (Philips Radiation Oncology Systems, Fitchburg, WI, USA) support is set to end by December 31, 2026. This work presents a validated method to archive Pinnacle data, which may be...