Absolute Measurement of HDR Ir-192 Air-Kerma Strength Using an Exradin A3 Known-Volume Ionization Chamber

Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

Investigating the Use of a DWI Phantom for Routine QA of an MR-Linac at Room Temperature

Authors: Nicholas Carlson, Joel J. St-Aubin

Affiliation: University of Iowa Hospitals and Clinics, University of Iowa

Abstract Preview: Purpose: To establish baselines metrics and determine longitudinal accuracy and reproducibility of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) values for a 1.5T Elekta Un...

Measurement of 90 Y Bremsstrahlung Dose with Thermoluminescent Dosimeters

Authors: David P. Adam, Bryan Bednarz, Tyler J Bradshaw, Wesley S. Culberson, Clifford G. Hammer, Sean Jollota, Ohyun Kwon, Jordan Teague

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiology, University of Wisconsin - Madison

Abstract Preview: Purpose: To quantify absorbed dose to water from 90YCl using thermoluminescent dosimeters (TLDs) and to acquire partial volume corrections for 90YCl positron emission tomography (PET).
Methods: Six...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Pulse-Based Method of Electrometer Calibration for High Instantaneous Currents Produced in Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Electrometers are fundamental instruments for absorbed dose determination, and their accuracy is strongly dependent on their calibration. The standard procedure of electrometer calibration is...

The Use of a Milled NIST Traceable Tld for End-to-End Validation in Mlc and Cone SRS Programs.

Authors: Ross Bland, Zachary A. Christ, Sophy Mangana, Feba Mathew, Stephanie K. Phoenix, Joseph Salloum, Jason D. Stanford, William Zollinger

Affiliation: Forrest General Cancer Center, Northeast Louisiana Cancer Institute, Florida Atlantic University

Abstract Preview: Purpose: The objective of this paper is twofold: 1) to explore the efficacy of using referenced beam models supplied by the vendor (Brainlab) and 2) the efficacy of NIST traceable TLD for end-to-end v...