Authors: Bryan Bednarz, Malick Bio Idrissou, Campbell Haasch, Reinier Hernandez
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, University of Wisconsin - Madison
Abstract Preview: Purpose: Quantitative optical imaging is a powerful tool in murine models for assessing tumor growth and metastatic spread using bioluminescence imaging (BLI) and for detecting radiopharmaceutical upt...
Authors: Cem Altunbas, Farhang Bayat
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic
Abstract Preview: Purpose:
Low dose imaging and scatter rejection hardware in CBCT reduces X-ray fluence incident on the imager, increasing noise, causing photon starvation artifacts in CBCT images. In this work, we...
Authors: Aditya P. Apte, Xinan Chen, Joseph O. Deasy, Ramesh Paudyal, Kyung Peck, Amita Shukla-Dave, Nathaniel Swinburne, Robert J. Young
Affiliation: Department of Radiology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: We apply our novel formulation of unbalanced-regularized-optimal-mass-transport (urOMT) theory to brain DCE-MRI data to quantify and visualize the behaviors of fluid flows in post-treatment f...
Authors: Taylor A Beal, Kari J. Brewer Savannah, Kristy K. Brock, Alejandro Contreras, Natalie W Fowlkes, Megan Kalambo, Gregory P Reece, Erin P Snoddy, Tien T Tang
Affiliation: The University of Texas MD Anderson Cancer Center, Baylor College of Medicine
Abstract Preview: Purpose: Current anatomical and surgical research does not adequately detail the breast fascial system’s ligaments and connective tissues. Most available information stems from cadaver dissections, wh...
Authors: Mateb Ali Alghamwa, Haya Aljuaid, Siyong Kim, Tianjun Ma, William Song
Affiliation: Virginia Commonwealth University
Abstract Preview: Purpose: The integration of Plastic Scintillation Detectors (PSDs) into 0.35T MR-Linac systems represents a significant advancement in radiotherapy, offering substantial benefits due to their tissue-e...
Authors: Jeremy Eric Hallett, Aubrey Parks, Brian W Pogue
Affiliation: University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Cherenkov imaging visualizes radiotherapy beams, assuming emission is proportional to deposited dose. However, attempts for Cherenkov as a quantitative dose estimation have been unsuccessful ...
Authors: Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Vikas Vikas, Brian C. Wilson, Weibing Yang, Timothy C. Zhu
Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania
Abstract Preview: Purpose:
Multispectral Singlet Oxygen Luminescent Dosimetry (MSOLD) has been developed as a real-time in vivo dosimetry technique for Photodynamic Therapy (PDT). This study investigates the feasibi...
Authors: Justus Adamson, Mu Chen, Ke Lu, Zhenyu Yang, Fang-Fang Yin, Rihui Zhang, Yaogong Zhang, Haipeng Zhao, Haiming Zhu, Yuchun Zhu
Affiliation: Shanghai Dacheng Medical Technology, Duke University, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan
Abstract Preview: Purpose: In filtered back-projection (FBP) reconstruction, conventional filters often reduce noise at the expense of high-frequency details, leading to structural details loss. To address this limitat...
Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler
Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...
Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...
Authors: Michael Burke, David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Vanessa Hill, Ann-Teresa Jasman, John Kim, Svetlana Kuznetsova, MinYoung Lee, Daniel Longo, Henry S. Park, Adam Shulman, Lauren Tressel, Weili Zhong
Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose:
The complexity of biology-guided radiotherapy (BgRT), particularly with systems like RefleXion X1, necessitates robust pre-treatment quality assurance (QA) to ensure patient safety, treatm...
Authors: Theresa Busch, Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Brian C. Wilson, Weibing Yang, Timothy C. Zhu
Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania
Abstract Preview: Purpose: Direct detection of singlet-state oxygen (¹O₂) is crucial for advancing type II photodynamic therapy (PDT), but its short lifetime makes in vivo measurement highly challenging. Although Photo...
Authors: Hassan Bagher-Ebadian, Justine M. Cunningham, Anthony J. Doemer, Mohammad M. Ghassemi, Joshua P. Kim, Benjamin Movsas, Kundan S Thind
Affiliation: Michigan State University, Henry Ford Health
Abstract Preview: Purpose: Reduction of noise in medical images critically enables improved accuracy in delineating tumors and organs at risk, leading to more precise treatment planning and safer image-guided radiation...
Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue
Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...
Authors: Yi-Fang Wang, Yading Yuan
Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...
Authors: Xiaoyu Duan, Xinyu Hu, Runqiu Li, Xiang Li
Affiliation: Dukekunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
Accurate detection of small-sized microcalcifications (μCalcs) (< 500 µm) is critical for early breast cancer diagnosis, requiring optimal imaging systems and reconstruction algorithms. Ho...
Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang
Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital
Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...
Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao
Affiliation: University of Miami
Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...
Authors: Xiangli Cui, Chunyan Fu, Man Hu, Wanli Huo, Jingyu Liu, Jianguang Zhang, Yingying Zhang, Shanyang Zhao
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Departments of Radiation Oncology, Zibo Wanjie Cancer Hospital, Key Laboratory of Electromagnetic Wave Information Technology and Metrology of Zhejiang Province, College of Information Engineering, China Jiliang University, Department of Oncology, Xiangya Hospital, Central South University, College of Information Engineering, China Jiliang University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University, Shandong Academy of Medical Sciences
Abstract Preview: Purpose: To quantify the impact of fine-tuning strategies for pre-trained AI image generation models on glioma MRI image quality and observer performance, and to determine the optimal fine-tuning conf...
Authors: Salman M. Arnab, Yves Chevalier, Samuel Gagné, Adrian F. Howansky, Luc Laperrière, Xiangyi Wu, Wei Zhao
Affiliation: Stony Brook Medicine, Analogic Canada
Abstract Preview: Purpose: A direct-indirect dual-layer flat-panel-detector (DI-DLFPD) is under development for patient motion artifact-free contrast-enhanced digital mammography (CEDM). DI-DLFPD comprises a direct fro...
Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington
Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center
Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...
Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous
Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...
Authors: Muhammed AR Anjum, Andrew J. Fagan
Affiliation: Mayo Clinic
Abstract Preview: Purpose:
This study describes a novel post-processing method to boost image SNR for deuterium-MRI acquired using chemical shift imaging (CSI) at 7T. Deuterium MRI via exogenous administration of a ...
Authors: Xu Cao, Wesley S. Culberson, Aubrey Parks, Brian W Pogue, William Scott Thomas
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison, University of Wisconsin - Madison, UW-Madison
Abstract Preview: Purpose:
The hydrated electron is a critical reactive species generated during the radiolysis of water when ionizing radiation interacts with biological tissues. It plays a pivotal role in mediatin...
Authors: Zhongping Chen, Yuchen Song, Leshan Sun, Liangzhong Xiang, Yifei Xu
Affiliation: University of California, Irvine, University of California Irvine
Abstract Preview: Purpose: Electroacoustic tomography (EAT) monitors the distribution of electrical energy in tissues by detecting acoustics signals induced by electrical pulses during irreversible electroporation (IRE...
Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li, Junzhong Xu
Affiliation: Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiology, Vanderbilt University Medical Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cell size is a vital parameter in evaluating the tumor microenvironment, including cell apoptosis and radiotherapy(RT)-induced immune cell infiltration. The IMPULSED(Imaging Microstructural P...
Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang
Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...
Authors: Marian Axente, Mandeep Kaur
Affiliation: Emory University
Abstract Preview: Purpose: To validate a low-cost optical imaging system for respiratory monitoring by comparing its accuracy and feasibility against the clinical gold standard in human subjects.
Methods: Following ...
Authors: Alex Lindgren-Ruby, Jeffrey M. Moirano, Joseph Everett Wishart
Affiliation: University of Washington
Abstract Preview: Purpose:
To evaluate polynomial fitting of signal intensity for signal-to-noise ratio (SNR) estimation from weekly QC ACR MRI phantom images and compare against other SNR estimation methods as well...
Authors: Jingyao Chen, Yingli Yang, Jie Zhang
Affiliation: Department of Radiology, Ruijin Hospital, Shanghai Ruijin Hospital, Shanghai United imaging Healthcare Advanced Technology Research Institute
Abstract Preview: Purpose: Magnetic Resonance Electrical Properties Tomography (MR EPT) is a method to spatially mapping the conductivity and permittivity based on small B1 field changes after the imaged object was int...
Authors: Guillermo Daniel Alvarez, Daniel Fino, Rocio Luz Gilli, Dorian Alexander Romero
Affiliation: School Foundation of Nuclear Medicine, INTECNUS Foundation, Nuclear Medicine and Radiotherapy Center of Southern Patagonia
Abstract Preview: Purpose: To evaluate the anatomical, functional, and molecular information from PET/MR images with F18-PSMA to identify intraprostatic lesions and delineate a boost in stereotactic body radiotherapy (...
Authors: Baozhu Lu, Hongjing Sun, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: This study aims to validate the feasibility of using Cherenkov imaging for surface dose distribution measurement during Total Skin Electron Therapy (TSET) by developing a perspective-correcte...
Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq
Affiliation: Khalifa University
Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...
Authors: Hoyeon Lee
Affiliation: University of Hong Kong
Abstract Preview: Purpose: Deep-learning approaches are widely investigated for Cone-Beam CT (CBCT) scatter correction to improve the quality of the linear-accelerator mounted CBCT. This study aims to optimize the deep...
Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy
Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College
Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...