Search Submissions 🔎

Results for "output factors": 40 found

A Bayesian Model for the Detection of Local Ventilation Changes in Lung Cancer Patients

Authors: Bas W. Raaymakers, Mario Ries, Paris Tzitzimpasis, Cornel Zachiu

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, University Medical Center Utrecht, UMC Utrecht

Abstract Preview: Purpose: Radiation pneumonitis affects approximately 10-30% of lung cancer patients treated with radiation therapy (RT), posing a significant dose-limiting factor. Recently developed CT-ventilation me...

A Dosimeter Independent Method for Measuring Dose from Contrast Enhanced Mammography Exposure.

Authors: Mitya M. Barreto, Nichole A. Harris

Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center

Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...

A Novel Approach to Preclinical Intensity-Modulated Radiotherapy Using an Open-Source Ring-Based Compensator Device and Inverse Treatment Planning System

Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo

Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

An Explainable Classifier for Enhancing the Quality Assurance of Digital Breast Tomosynthesis Phantom Images

Authors: Hui-Shan Jian, Yu-Ying Lin

Affiliation: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou

Abstract Preview: Purpose: The image quality assurance of mammographic images is crucial for correct diagnosis. To develop and validate an explainable deep-learning classifier for phantom image quality assessment of di...

An Integrated, Web-Based Tool for Automated Treatment Time Calculations, Data Visualization, and Documentation for Superficial Radiotherapy Using an SRT-100 Vision

Authors: Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, Michael Leyva, Alejandro Rene Llanes Lopez, Carlos M. Rivera, Ranjini P. Tolakanahalli

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health

Abstract Preview: Purpose: Accurate treatment time calculation is a critical component of superficial radiotherapy (SRT), particularly for the SRT-100 Vision, where dose delivery depends on applicator geometry, treatme...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Characterization and Validation of Cerenkov Radiation Extraction Methods from a Plastic Scintillation Detector in 0.35T MR-Linac Environments

Authors: Mateb Ali Alghamwa, Haya Aljuaid, Siyong Kim, Tianjun Ma, William Song

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: The integration of Plastic Scintillation Detectors (PSDs) into 0.35T MR-Linac systems represents a significant advancement in radiotherapy, offering substantial benefits due to their tissue-e...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Construction and Application Study of a Deep Learning-Based Iscout-Guided Precision Radiotherapy Positioning Error Prediction Model for Breast Cancer

Authors: Fangfen Dong, Jiaming Li, Xiaobo Li, Weipei Wang, Zhixin Wang, Bing Wu, Benhua Xu, Yong Yang, Yifa Zhao

Affiliation: Department of Radiation Oncology, Fujian Medical University Union Hospital/Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematologi, Zhangpu County Hospital, School of Medical Imaging, Fujian Medical University

Abstract Preview: Purpose: To explore the construction and clinical application value of a deep learning-based positioning error prediction model, providing a reference for optimizing iSCOUT system-guided precision rad...

Directional Dependence of Detectors for Beam Profiles and Output Factors in Small Field Dosimetry

Authors: Indra J. Das, Ahtesham Ullah Khan, Andrew J. White

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: Small field dosimetry presents challenges due to lateral disequilibrium and the selection of suitable detectors. Volume averaging and density corrections hamper accurate profile measurements....

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Experience in Commissioning and Quality Assurance of Halcyon Linear Accelerator Ver3.0 at a Community Hospital and an Academic Institution

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose:
The Varian Halcyon Linear Accelerator has become increasingly popular in both community hospitals and academic institutions due to its user-friendly design and operational efficiency. This...

Feasibility Study on Creating a Digital Twin of Digital Subtraction Angiography Data Utilizing Monte Carlo and Computational Fluid Dynamic Simulations

Authors: Ciprian N. Ionita, Parisa Naghdi, Ahmad Rahmatpour

Affiliation: University at Buffalo, SUNY: University at Buffalo

Abstract Preview: Purpose: Quantitative angiography (QA) evaluates neurovascular hemodynamics, but is affected by X-ray parameters, vessel foreshortening, and imaging chain factors like detector efficiency, pixel size,...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

HDR End-to-End Testing of Horizontal Leipzig Skin Applicators with Ir-192 Calibrated Oslds

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell

Affiliation: Mount Sinai Beth Israel

Abstract Preview: Purpose: Commissioning of Flexitron HDR horizontal Leipzig applicators typically includes indirect or direct output verification, using a well chamber specific Revised Correspondence Factor (CFrev) or...

Identification of Potential Patients for Resimulation and Adaptive Planning By Machine Learning

Authors: Mark Ashamalla, Renee Farrell, Jinkoo Kim, Kartik Mani, Xin Qian, Samuel Ryu, Yizhou Zhao

Affiliation: Stony Brook Medicine, Stony Brook University Hospital

Abstract Preview: Purpose: Adaptive planning is increasingly used in head and neck radiation therapy due to factors like tumor response or changes in patient anatomy. However, methods such as resimulation or offline re...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Impact of Jaw Reproducibility and Source Occlusion on Small Field Dosimetry

Authors: Mylinh Dang, Indra J. Das, George X. Ding, Ahtesham Ullah U Khan, Andrew J. White

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine, Vanderbilt University Medical Center

Abstract Preview: Purpose: The large variability in field output factor (FOF) observed among various studies is speculated to be due to uncertainty in jaw reproducibility that is linked directly with source occlusion. ...

Implementing TG-191 for Robust Calibration of Scintillation Imaging As a Clinical dosimetry Tool

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...

Improving Output Stability with Angular Correction Factor on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...

Initial Three-Year Machine Performance Assessment of a Superficial Radiation Therapy Unit

Authors: Vibha Chaswal, Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, William Romaguera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: To report machine performance of our superficial radiation therapy unit (SRT-100 Vision, Sensus Healthcare, Boca Raton, FL) for the first three years after commissioning of the unit.
Metho...

Investigating Factors Impacting the Consistency of Signal-to-Noise Ratio in Mammographic Automatic Exposure Control

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the impact of tissue-equivalent attenuator materials, the region of interest (ROI) size, and the orientation of the attenuator positioning on the measured signal-to-no...

Knowledge-Informed Deep Learning for Accurate and Interpretable Extracapsular Extension Detection in Head and Neck Squamous Cell Carcinoma

Authors: William N. Duggar, Amirhossein Eskorouchi, Haifeng Wang

Affiliation: Mississippi State University, University of Mississippi Medical Center

Abstract Preview: Purpose:
Extracapsular extension (ECE) in lymph nodes represents a critical prognostic factor in head and neck squamous cell carcinoma (HNSCC), bearing important implications for staging, treatment...

Patient Specific Protocol Optimization in Cardiac CT: A Practical Approach to Its Validation

Authors: Zhihua Qi

Affiliation: Henry Ford Health

Abstract Preview: Purpose: State of the art cardiac CT has built-in automated, patient specific optimization, taking into account a number of factors including patient size, heart rate and others. It is crucial to deve...

Predicting Proton Therapy Dose Delivery Accuracy: A Machine Learning Approach Using Iroc’s Proton Phantom Data

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop a machine learning model for predicting dose delivery accuracy and identifying its key factors in IROC’s proton phantom program.
Methods: IROC’s proton QA program has six proton...

Real-Time Output Gating and Fault Handling for an Uhdr Mobetron

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

Streamlining Orthovoltage QA: Feasibility of IC Profiler Dosimetry and Workflow Optimization

Authors: Huixiao Chen, Zhe (Jay) Chen, MinYoung Lee, Sameer Taneja

Affiliation: Yale School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Superficial radiation therapy uses low-energy x-rays to treat various types of cancers, including non-melanoma skin cancers, and dermatological conditions such as keloid scars, mycosis fungoi...

The Root Cause of Large Differences in Calculated Beam Monitor Units between a Treatment Planning System and a QA Software

Authors: George X. Ding, Kenneth L. Homann

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: It is standard practice that the beam monitor units (MUs) calculated by a commercial treatment planning system (TPS) is verified by a secondary dose calculation (SDC) software that independen...

The Use of a Milled NIST Traceable Tld for End-to-End Validation in Mlc and Cone SRS Programs.

Authors: Ross Bland, Zachary A. Christ, Sophy Mangana, Feba Mathew, Stephanie K. Phoenix, Joseph Salloum, Jason D. Stanford, William Zollinger

Affiliation: Forrest General Cancer Center, Northeast Louisiana Cancer Institute, Florida Atlantic University

Abstract Preview: Purpose: The objective of this paper is twofold: 1) to explore the efficacy of using referenced beam models supplied by the vendor (Brainlab) and 2) the efficacy of NIST traceable TLD for end-to-end v...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

“See” through Surface: Transforming Surface Imaging into a Real-Time Three-Dimensional Imaging Solution for Intra-Treatment Image Guidance

Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...