A Comparison of Segment-By-Segment Versus Cumulative Signal Evaluation for Patient-Specific QA Using the Integral Quality Monitor

Authors: John J. DeMarco, Farideh Pak, Olivia Grahm C Valadie

Affiliation: Cedars Sinai, Cedars-Sinai, Cedars-Sinai Medical Center

Abstract Preview: Purpose: To investigate the performance of the Integral Quality Monitor (IQM) device for patient-specific QA, focusing on segment-by-segment signal evaluation compared to cumulative signal evaluation....

A Deep Learning Approach to the Prediction of Gamma Passing Rates in VMAT Radiotherapy Plans for Adaptive Treatment.

Authors: Jenghwa Chang, Kuan Huang, Lyu Huang, Jason Lima, Jian Liu, Farzin Motamedi

Affiliation: Northwell, Department of Computer Science and Technology, Kean University, Physics and Astronomy, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Title: A Deep Learning Approach to the Prediction of Gamma Passing Rates in VMAT Radiotherapy Plans for Adaptive Treatment.
Purpose: This study aims to develop a deep learning algorithm to predict ...

A Deep Learning-Based Approach for Rapid Prediction of IMRT/VMAT Patient-Specific Quality Assurance for Online Adaptive Plans Generated with a 0.35T MR-Linac

Authors: Suman Gautam, Tianjun Ma, William Song

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: We propose an artificial intelligence (AI)-based method to rapidly predict the patient-specific quality assurance (PSQA) results for magnetic resonance (MR)-guided online adaptive radiation th...

A Retrospective Analysis of Automatic Exposure Control (AEC) Tracking Failure Rates in Radiographic Systems

Authors: Benjamin W. Maloney, Ashley E. Rubinstein, Colin Schaeffer, Justin Yu

Affiliation: Henry Ford Health

Abstract Preview: Purpose: Radiography AEC systems ensure correctly exposed images for varied kVp and patient thicknesses. The specific kVp and PMMA thicknesses selected for testing AEC tracking may affect passing rate...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Automated Decision Workflow Using Fast Monte Carlo Dose Calculations for Daily Adaptive Proton Therapy

Authors: Ergun E. Ahunbay, Abdul Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao

Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Online adaptive replanning is often necessary in Intensity Modulated Proton Therapy (IMPT) due to the sensitivity of proton dose distributions to daily anatomical changes. A rapid, automated ...

Brachyplancheck: An Independent Monte Carlo Dose Calculation Tool for Brachytherapy Using Egs_Brachy

Authors: Amy Tien Yee Chang, Chi Wai Cheung, Tin Lok Chiu, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study introduces BrachyPlanCheck, an independent Monte Carlo (MC)-based dose calculation tool for 192Ir brachytherapy retrospective study or algorithm commissioning.
Methods: BrachyPl...

Clinical Assessment of Synthetic CT in MR-Only Brain Radiotherapy

Authors: Ergun E. Ahunbay, Colette Gage, Abdul Kareem Parchur, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: AI-generated synthetic CT (sCT) images address challenges with prior sCT approaches, including atlas- and threshold-based methods. Commercial AI-based sCT tools have been introduced. This wor...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Clinical Implementation of a Film Based Psqa System for SBRT on a 1.5T MR-Linac

Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal

Affiliation: Sunnybrook Health Sciences Centre

Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...

Clinical Validation of Fully Automated Script for Plan Conversion between Linacs with Different Mlc Model

Authors: David L. Barbee, Paulina E. Galavis, Lena Adel Samad, Jose R. Teruel Antolin

Affiliation: NYU, NYU Langone Health

Abstract Preview: Purpose: To validate an automated script that converts treatment plans of varying Varian MLC models

Methods: A C# script was developed using the Eclipse Scripting API to convert treatment plans...

Comparison of Portal Dosimetry and Delta4® for Pretreatment QA of Sfrt-VMAT Plans

Authors: Tianyuan Dai, Zejun Jiang, Xiangyue Kong

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose:
This study aims to evaluate the reliability of SFRT-VMAT plan verification by comparing two QA methods: Portal Dosimetry (PD) and Delta4®.
Methods:
Preteatment QA was conducted for 1...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Development of Treatment Planning System for Carbon Ion Radiotherapy in Yonsei Cancer Center

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Establishing Tumor Size-Dependent Contrast Requirements for Multi-Target Biology-Guided Radiation Therapy (BgRT)

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To determine minimum target size and FDG contrast thresholds for reliable Biology-guided Radiation Therapy (BgRT) delivery using a systematic phantom study.
Methods: A custom 3D-printed ph...

Establishing a Protocol for Quality Assessment of Ultrasound Shear Wave Elastography (SWE) and Application to a Musculoskeletal (MSK) Task

Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...

Evaluation of Four Different Dose Calculation Algorithms for Commissioning of a New Tyoe of Scanned Proton Therapy System

Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga

Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University

Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

Feasibility of Commercial Independent-Dose-Calculation for Pencil-Beam-Scanning Proton Therapy

Authors: Wen C. Hsi, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...

Feasibility of Using a Dynamic-Platform with High-Resolution Patient-Specific QA Device for Periodic and Patient-Specific-QA in Respiratory-Gated Radiotherapy Lung SBRT Treatment

Authors: Tae Kyu Lee

Affiliation: Allina Health

Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...

First Phantom Testing of Biology-Guided Radiotherapy for Sequential Integrated Boost Radiotherapy

Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Mlc and Collimator Errors in Psqa Techniques for VMAT Breast Treatment Plans

Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Investigation of the Impact of Dlg Changes on Plan Quality and Patient Specific QA

Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold

Affiliation: Scripps Cancer Center

Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...

Knowledge-Based Deep Residual U-Net for Synthetic CT Generation Using a Single MR Volume for Frameless Radiosurgery

Authors: Justus Adamson, John Ginn, Yongbok Kim, Ke Lu, Trey Mullikin, Xiwen Shu, Chunhao Wang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Duke Kunshan University

Abstract Preview: Purpose:
To develop a knowledge-based deep model for synthetic CT (sCT) generation from a single MR volume in frameless radiosurgery (SRS), eliminating the need for CT simulation prior to the SRS d...

On the Sensitivity Evaluation of End-to-End Test in Radiotherapy

Authors: Yussuf A. Abdelal, Sebastien A. Gros, Luke Layman, Anil Sethi

Affiliation: Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago

Abstract Preview: Purpose:
End-to-end (E2E) test is a vital QA check of the overall radiotherapy process from simulation imaging to treatment delivery. Although clinical passing criteria are available, guidelines on...

One Year Experience of Biology-Guided Radiotherapy (BgRT) on PET-Linac in an Academic Center

Authors: Shahed Badiyan, Girish Bal, Thomas I. Banks, Bin Cai, Tu Dan, Aurelie Garant, Andrew R. Godley, Steve Jiang, Orhan Oz, Arnold Pompos, Rameshwar Prasad, Chenyang Shen, David Sher, Robert Timmerman, Kenneth Westover

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) is a novel FDA-cleared technology for treating lung and bone tumors based on 18F-FDG PET uptake. This study summarizes the first-year experience treating 29...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-Chacón, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Prior-Informed Neural Super-Resolution Dosimetry for Radiotherapy QA from Sparse Dosimeter Arrays

Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...

Real Time Monte Carlo Dose Calculation for Clinical Cyberknife Radiation Therapy Based on Deep Learning Diffusion Model

Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...

Reproducibility of a Unique Prone Head and Neck Setup Evaluated with In Vivo Epid Dosimetry System

Authors: Salim Balik, Eric Chang, Kristine Garcia, Andrew Islas, Lijun Ma, Zhilei Liu Shen, Elizabeth Zhang-Velten

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: NRG protocols recommend simulating and treating head and neck (HN) cancer patients in a supine position for optimal setup reproducibility. However, certain patients cannot tolerate the supine...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

Universal MR-to-Synthetic CT: A Streamlined Framework for MR-Only Radiotherapy Planning

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
Converting MR images to synthetic CT (MR2sCT) is highly desirable as it streamlines the radiotherapy treatment planning workflow. This approach leverages the superior soft tissue visibilit...