Search Submissions ๐Ÿ”Ž

Results for "per pulse": 27 found

A Perturbative Approach to Determine the Charge Collection Efficiency in High Dose-per-Pulse Beams

Authors: Julien Bancheri, Jan P. Seuntjens

Affiliation: Medical Biophysics, University of Toronto, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: To obtain an analytical expression for the charge collection efficiency of parallel-plate ionization chambers in high dose-per-pulse (DPP) beams that takes into account the square pulse time ...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

Calorimetric Measurement of Absorbed Dose By a Flash Beamline

Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor

Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.

Methods: Electron FLASH beams of 6 MeV and 9 Me...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstรคtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Design and Testing of an External Control System for Beam Control and Pre-Delivery Optimization for Conventional- and Ultra-High-Dose-per-Pulse Flash Irradiations

Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler

Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...

Design, Optimization, and Preclinical Validation of a Novel Applicator Integrating Real-Time Dose Monitoring for Ultra-High Dose Rate (FLASH) Electron Radiotherapy

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...

Development of a Cadmium Zinc Telluride (CdZnTe) Detector-Based Neutron Imaging System

Authors: Soo Hyun Byun, Troy Farncombe, Edcer Jerecho DC Laguda

Affiliation: McMaster University

Abstract Preview: Purpose: We present the adaptation of a Cadmium Zinc Telluride (CdZnTe) detector, initially designed for SPECT-MR applications, to neutron imaging. This study explores a novel technique that utilizes ...

Dosex As a per-Pulse Uhdr and Conventional Electrometer Compatible with Sandard Clinical Probes

Authors: Petr Bruza, David J. Gladstone, Austin Sloop, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Health

Abstract Preview: Purpose: UHDR-specific probes are becoming available on the market but often demand high costs and long order times. The reduced sensitivity of these probes often imposes challenges when measuring con...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the โ€œFLASH effectโ€. How...

Dynamic X-Ray Acoustic Computed Tomography (XACT)

Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan

Affiliation: University of California, Irvine

Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluation of Charge Collection Performance in the A30 Prototype Parallel Plate Ion Chamber in Ultra-High Dose Rate Beam

Authors: Mervat A. Alharbi, Wesley S. Culberson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Medical Physics Department, School of medicine and Public Health, University of Wisconsin-Madison

Abstract Preview: Purpose: The charge collection using ionization chambers is challenging at ultra-high dose rates (UHDR) due to the high ion recombination The Exradin A30 prototype parallel-plate ion chamber manufactu...

First Beam Characterization of the Radiabeam FLEX-9 Electron Flash Linac

Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron

Affiliation: RadiaBeam Technologies, University of Iowa

Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...

Immobilization and Optimization of Pulse Sequences for 0.23T MRI

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Monitor Unit (MU) Substructure Analysis for Low MU Deliveries

Authors: Indra J. Das, Ahtesham U. Khan, Andrew J. White, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: During intensity modulated radiotherapy (IMRT) planning, low MU segments (< 3 MU) are commonly avoided due to documented dosimetric nonlinearity and poor reproducibility. This work aims to ex...

On Designing a Vascular Flow Phantom for Contrast-Enhanced Ultrasound Imaging

Authors: Kevin M Brom, Josep Chorro Bas, RosaAnna Chorro Bas, Andres Climent Rubio, Jaydev K. Dave, Tobias Kummer, Larissa Shiue, Donald J Tradup

Affiliation: Mayo Clinic, Prehospital Critical Care Training Group

Abstract Preview: Purpose: To design and evaluate the functionality of a vascular flow phantom for contrast-enhanced ultrasound imaging (CEUS).

Methods: A microcontroller-generated signal was amplified by a cust...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Pulse-Based Method of Electrometer Calibration for High Instantaneous Currents Produced in Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Electrometers are fundamental instruments for absorbed dose determination, and their accuracy is strongly dependent on their calibration. The standard procedure of electrometer calibration is...

Real-Time Output Gating and Fault Handling for an Uhdr Mobetron

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...

Reduction of the Charge Build-up Effect on the Beam Current Transformers for Real-Time Monitoring of Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Beam current transformers (BCTs) are a promising alternative to ion chambers for real-time monitoring of ultra-high dose per-pulse (UHDPP) beams. The signal of the BCT is insensitive to ion r...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...

Slit Scanning Delivery Simulation for Flash Radiotherapy

Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...

The Feasibility of Ethos-Based Pulsed Reduced Dose-Rate (PRDR) Radiotherapy

Authors: Chia-Lung Chien, Renteng Hou, Wen C. Hsi, Faraz Kalantari, Ganesh Narayanasamy, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
PRDR is an effective re-irradiation treatment for patients who have already reached the tolerance dose to their organs at risk (OARs). While PRDR is implemented on TrueBeam by limiting the...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...