Search Submissions ๐Ÿ”Ž

Results for "per rotation": 23 found

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

An Agglomerative Clustering-Based Program for Optimizing Multiple-Target SRS Treatment Planning

Authors: Josephine Chen, CheukKai Becket Hui, Yildirim D. Mutaf

Affiliation: Kaiser Permanente

Abstract Preview: Purpose:
To demonstrate the effectiveness of a target clustering program in generating cluster configurations and isocenter placements for multiple brain lesions in SRS treatment planning, with the...

Assessment of the Impact of CT Respiratory Motion on PET SUV Quantification through Virtual Imaging

Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington

Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...

Automatic 4D Lung PET-CT Segmentation Using Hybrid Deep Neural Network

Authors: Hongyi Jiang, Fang-Fang Yin

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...

Characterizing and Modeling Higher-Order Motions of Collimator Subsystem on a 60RPM Gantry Linac for Improved Small Target Dosimetry

Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...

Comparison of Frame-Based and Frameless Gamma Knife Coordinate Spaces for Treatment of Trigeminal Neuralgia

Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...

Contrast Volume Prediction Using CT Dose Metrics

Authors: Niki Fitousi, Anna Romanyukha, Stuart Utting

Affiliation: University Hospitals Dorset, Qaelum NV

Abstract Preview: Purpose:
For increased patient safety and with a focus on sustainability in the radiology department, efforts are being made to optimize contrast media usage. In this study, the possibility of util...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patientโ€™s nose relative to two stationary reflectors on th...

Dual-Domain Reconstruction Network for Nonstop Gated CBCT Imaging: Application in Respiratory Gating Ablative Radiotherapy for Pancreatic Cancer

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yabo Fu, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Boris Mueller, Huiqiao Xie, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gating ablative radiotherapy for pancreatic cancer accounts for tumor movement due to respiration and typically requires 5, 15, or 25 fractions. Pretreatment imaging verification is essential...

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Film-Based Method for Accurate Radiation Isocenter Determination in Linear Accelerators Using 3D Starshot

Authors: Robert A. Corns, Mohammad Kanber

Affiliation: East Carolina University, East Carolina University Brody School of Medicine

Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...

Global Medical Physics Graduate Clinical Training and Development Program

Authors: Eric Addison, Stephen M. Avery, Alhassan Mohammed Baidoo, Lyna Dinh, Megan Doherty, Andrew Friberg, Sonya Gwak, Francis Hasford, Stephen Inkoom, Shannon E. O'Reilly, Ayoola Okuribido, Edem Sosu, Samuel Nii Adu Tagoe

Affiliation: University of Wisconsin, Komfo Anokye Teaching Hospital, Ghana Atomic Energy Commission, Korle Bu Teaching Hospital, University of Pennsylvania, University of Ghana, Sweden Ghana Medical Centre

Abstract Preview: Purpose: This first-of-its-kind Global Medical Physics Training and Development Program (GMPTDP) seeks to serve as an opportunity for graduate students to enhance their clinical training with a global...

High-Temporal Dynamic CBCT Imaging Via Gaussian Neural Representation

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...

Incorporating Cyclic Group Equivariance into Deep Learning for Reliable Reconstruction of Rotationally Symmetric Tomography Systems

Authors: Fang-Fang Yin, Lei Zhang, Yaogong Zhang

Affiliation: Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Rotational symmetry is an inherent property of many tomography systems (e.g., CT, PET, SPECT), arising from the circular arrangement or rotation of detectors. This study revisits the image re...

Investigating Gammatile Migration: Implications for Dosimetry and Clinical Outcomes

Authors: Wesley A. Belcher, Robert A. Corns, Jae Won Jung, Matthew S Peach, Swarup Sharma

Affiliation: The University of North Carolina at Chapel Hill, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: GammaTiles are a novel intracranial brachytherapy approach designed to directly deliver radiation therapy to residual or recurrent brain tumors following resection. Despite their promising th...

Is Your Resident Ready to Become a Brachytherapy Physicist? a Training Exercise and Evaluation Tool in HDR Brachytherapy Planning Errors

Authors: Amar K. Basavatia, Lee C. Goddard, Wolfgang A. Tomรฉ, Christian Velten, Ping Yan, Ravindra Yaparpalvi, Maria Stefania diMayorca

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: High dose rate (HDR) brachytherapy planning is a high-risk procedure performed under significant time pressure, with human failure being the leading cause of error. To elevate training for me...

Optimizing Phantom Measurement of Simt Radiosurgery

Authors: Mark W. Geurts, Bridget Ann Melke

Affiliation: Aspirus Health

Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...

Performance Analysis of Various Deep Learning Networks for Classification of True and False Positive 18F-PSMA Findings

Authors: Vasiliki Chatzipavlidou, Ilias Gatos, George C. Kagadis, Theodoros Kalathas, Paraskevi Katsakiori, Anna Makridou, Dimitris N. Mihailidis, Nikos Papathanasiou, Ioanna Stamouli, Stavros Tsantis

Affiliation: Theageneio Hospital, University of Pennsylvania, University of Patras

Abstract Preview: Purpose: To compare the performance of multiple deep learning (DL) networks, including DenseNet201, InceptionV3, MobileNetV3, EfficientNetB2, NASNetMobile, VGG19, ResNet50, and Xception, in classifyin...

Robust Evaluation of Rotational Uncertainties on Single-Isocenter Multi-Target Stereotactic Radiosurgery Hyperarc Treatment

Authors: Albert Admasu, Kayla Alfonso, Maria de la Luz De Ornelas, Nesrin Dogan, Eric Mellon, Yunze Yang

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Rotational uncertainties in single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) HyperArc treatments can cause additional target displacement, potentially degrading overall pl...

Surface Mapping of Couch Kick Cherenkov Images for Rotation-Independent Treatment Verification in External Beam Radiotherapy

Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: During external beam radiation therapy, couch kicks are often necessary to achieve effective treatments, yet they make interpreting Cherenkov images much more challenging. We present a surfac...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in todayโ€™s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

Time-Resolved CBCT: A Novel Solution for Motion Management

Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang

Affiliation: The University of Chicago

Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...

Uncertainty Analysis of Hyperarc VMAT Plans for Stereotactic Radiosurgery Patients with Multiple Brain Metastases

Authors: Shifeng Chen, Yannick P. Poirier, Huijun Xu, Byong Yong Yi, Baoshe Zhang, Hong Zhang, Jinghao Zhou

Affiliation: University of Maryland School of Medicine, University of Maryland Shore Regional Cancer Center, Vanderbilt University Medical Center, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center

Abstract Preview: Purpose: To thoroughly assess the resilience of HyperArc VMAT plans for multiple brain metastases (MBT) in relation to (i) high-definition MLC leaf positional inaccuracies and (ii) patient rotational ...