Search Submissions šŸ”Ž

Results for "pet scans": 133 found

18F-FDG PET/CT-Based Deep Radiomic Models for Enhancing Chemotherapy Response Prediction in Breast Cancer

Authors: Ke Colin Huang, Zirui Jiang, Joshua Low, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Enhancing the accuracy of tumor response predictions enables the development of tailored therapeutic strategies for patients with breast cancer (BCa). In this study, we developed deep-radiomi...

23na Magnetic Resonance Imaging k-Space Denoising

Authors: Lorenzo Arsini, Andrea Ciardiello, Fabio Massimo D'Amore, Stefano Giagu, Federico Giove, Carlo Mancini-Terracciano, Cecilia Voena

Affiliation: Istituto Superiore di SanitĆ , Sapienza University of Rome, UniversitĆ  Sapienza Roma, Magnetic Resonance for Brain Investigation Laboratory, Museo Storico della Fisica e Centro di Studi e Ricerche Enrico Fermi

Abstract Preview: Purpose: To leverage newly developed heteronuclear magnetic resonance imaging (MRI) techniques, particularly sodium (23Na) imaging, for identifying potential biomarkers of Alzheimer's disease—such as ...

4D CBCT Dynamic Images Recovery Using a 4D Neural Network

Authors: Ziheng Deng, Yao Hao, Runping Hou, Deshan Yang, Jun Zhao, Yufu Zhou

Affiliation: Department of Radiation Oncology, Duke University, School of Biomedical Engineering, Shanghai Jiao Tong University, Washington University School of Medicine, Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: 4D CBCT has been developed to provide dynamic images for image-guided radiation therapy. However, as projection data are sorted into sparse and clustered phase-specific bins, 4D CBCT images a...

A Bayesian Model for the Detection of Local Ventilation Changes in Lung Cancer Patients

Authors: Bas W. Raaymakers, Mario Ries, Paris Tzitzimpasis, Cornel Zachiu

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, University Medical Center Utrecht, UMC Utrecht

Abstract Preview: Purpose: Radiation pneumonitis affects approximately 10-30% of lung cancer patients treated with radiation therapy (RT), posing a significant dose-limiting factor. Recently developed CT-ventilation me...

A Deep Learning Method for Direct Vmi Inference Using a Dual-Layer Radiotherapy Kv-CBCT Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: A challenge for dual energy CBCT is that noise and residual errors in material decomposition steps can become amplified when forming low energy, high contrast virtual mono-energetic images (V...

A Method to Expedite Quality Assurance for Head and Neck Ctvs with Lymph Node Level Auto-Autocontouring and Identification

Authors: Beth M. Beadle, Adrian Celaya, Laurence Edward Court, David Fuentes, Anna Lee, Tze Yee Lim, Dragan Mirkovic, Amy Moreno, Raymond Mumme, Tucker J. Netherton, Callistus M. Nguyen, Jaganathan A Parameshwaran, Jack Phan, Carlos Sjogreen, Sara L. Thrower, Congjun Wang, He C. Wang, Xin Wang

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, Stanford University, The University of Texas MD Anderson Cancer Center, MD Anderson Cancer Center, MD Anderson, Rice University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Quality assurance of target volumes from radiotherapy clinical trials is a labor and resource intensive task. The purpose of this work is to quantify the accuracy of a tool that automatically...

A Two-Marker Method for Calculating the Radiological Magnification of the Hip in Standing Pelvic Radiography

Authors: Walaa Abdelfadeel, Reagan Thomas Dugan, Tiffany Kinsey, Cameron Kofler, Zheng Feng Lu, Ingrid S. Reiser, Gregory Stacy, Sara Wallace

Affiliation: University of Chicago Medicine, University of Chicago

Abstract Preview: Purpose: To develop an accurate, vendor-neutral method for estimating geometric magnification at the plane of the hip joint on standing anterior-posterior (AP) radiographs for digital templating of to...

A Virtual 4DCT Generator Based on a Digital Phantom with Joint Cardiac and Respiratory Motions

Authors: Phillip Cuculich, Geoffrey D. Hugo, Xiwen Li, Michael T. Prusator, Clifford Robinson, Pamela Samson, Xue Wu

Affiliation: Washington University School of Medicine in St Louis, Washington University School of Medicine in St. Louis, University of Utah, WashU Medicine

Abstract Preview: Purpose:
For development of novel motion management methods it is useful to have a digital phantom capable of realistic simulation of respiratory 4DCT acquisition of the thorax, including cycle-to-...

AI-Based Registration-Free 3T T2-Weighted MRI Synthesis Using Truefisp MRI Acquired on a 0.35T MR-Linac System

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Cynthia Fu-Yu Chuang, Yu Gao, Dimitre Hristov, Lianli Liu, Lawrie Skinner, Lei Xing

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose:
MR-guided radiation therapy has introduced a significant leap in cancer treatment by allowing adaptive treatment. The low-field MR-guided system predominantly uses the TrueFISP sequence, w...

AI-Based SBRT Dose Prediction Directly from Diagnostic PET/CT: Applications for Multi-Disciplinary Lung Cancer Care

Authors: Pradeep Bhetwal, Wookjin Choi, Adam Dicker, Rupesh Ghimire, Yingcui Jia, Lauren Nkwonta, Yevgeniy Vinogradskiy, Wentao Wang, Maria Werner-Wasik

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Multi-disciplinary clinics are becoming standard of care for patients with lung cancer treated with SBRT. To improve clinical decision support in a multi-disciplinary clinic, it would be bene...

An Adaptive Radiotherapy Strategy Study Based on Segmented Synthesis and Deformational Registration

Authors: Jie Hu, Zhengdong Jiang, Nan Li, Tie Lv, Yuqing Xia, Shouping Xu, Gaolong Zhang, Wei Zhao, Changyou Zhong

Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Radiotherapy Department of Meizhou People’s Hospital (Huangtang Hospital), UT Health San Antonio, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, Peopleʼs Republic of China, Department of Radiation Oncology

Abstract Preview: Purpose: Patients usually undergo cone-beam computed tomography (CBCT) scans which are used for patient set-up before radiotherapy. However, the low image quality of CBCT hinders its use in adaptive r...

An Advanced Automated Pipeline for Brain Tumor Segmentation on MRI Images in Gamma Knife Radiotherapy

Authors: Zachery Colbert, Matthew Foote, Michael Huo, Mark Pinkham, Prabhakar Ramachandran, Mihir Shanker

Affiliation: Radiation Oncology, Princess Alexandra Hospital, Ipswich Road, Princess Alexandra Hospital

Abstract Preview: Purpose: The study aimed to develop and implement deep learning-based autosegmentation models for the autosegmentation of four key tumor types: brain metastasis, pituitary adenoma, vestibular schwanno...

An Efficient Deep Learning Model with Multi-Scale Integration for Automated Pancreas Segmentation on MR Images

Authors: Jingyun Chen, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology

Abstract Preview: Purpose: To develop and evaluate the Scale-attention network (SANet) for automated pancreas segmentation on MR images.
Methods: To develop SANet, we extended the classic U-Net design with a dynamic...

Application and Analysis of Advanced 3D Printed Materials As Bolus for Radiation Therapy

Authors: Rami M. Shorti, Gary R. Stinnett

Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department

Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...

Assessing the Risks of Synthetic MRI Data in Deep Learning: A Study on U-Net Segmentation Accuracy

Authors: Chuangxin Chu, Haotian Huang, Tianhao Li, Jingyu Lu, Zhenyu Yang, Fang-Fang Yin, Tianyu Zeng, Chulong Zhang, Yujia Zheng

Affiliation: The Hong Kong Polytechnic University, Nanyang Technological University, Australian National University, Medical Physics Graduate Program, Duke Kunshan University, North China University of Technology, Duke Kunshan University

Abstract Preview: Purpose: Deep learning segmentation models, such as U-Net, rely on high-quality image-segmentation pairs for accurate predictions. However, the recent increasing use of generative networks for creatin...

Assessment of the Impact of CT Respiratory Motion on PET SUV Quantification through Virtual Imaging

Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington

Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...

Automated Framework for Predicting Tumour Growth in Vestibular Schwannomas Using Contrast-Enhanced T1-Weighted MRI

Authors: Mehdi Amini, Minerva Becker, Simina Chiriac, Alexandre Cusin, Dimitrios Daskalou, Ghasem Hajianfar, Sophie Neveu, Marcella Pucci, Yazdan Salimi, Pascal Senn, Habib Zaidi

Affiliation: Geneva University Hospital, Division of Radiology, Diagnostic Department, Geneva University Hospitals, Service of Otorhinolaryngology-Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals

Abstract Preview: Purpose: Personalized prediction of vestibular schwannoma (VS) tumour growth is crucial for guiding patient management decisions toward observation versus intervention. This study proposes an automate...

Automated MR Segmentation for Online Adaptive MR-Linac Therapy Using an in-House Model

Authors: David L. Barbee, David Byun, Matt Long, Jose R. Teruel Antolin, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
Online adaptive MR-Linac therapy requires contour adaptation, often adding 20 minutes to treatment time and reducing machine throughput. This study introduces a fully automated MR contour ...

Automated Tool for Radiotherapy Initial Patient Setup: A Robust Approach Based on Vertebral Identification

Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute

Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...

BEST IN PHYSICS MULTI-DISCIPLINARY: Motion-Resolved Dynamic CBCT Reconstruction Using Prior-Model-Free Spatiotemporal Gaussian Representation (PMF-STGR)

Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...

Bayesian Mixture Modelling of Apparent Diffusion Coefficients from Whole-Body MRI Reveals Significant Changes in Metastatic Lesions Treated with Stereotactic Body Radiotherapy Compared to Untreated Controls

Authors: Giacomo Avesani, Matthew D Blackledge, Silvia Bottazzi, Alison Tree, Nina Tunariu

Affiliation: Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Institute of Cancer Research, The Royal Marsden NHS Foundation Trust

Abstract Preview: Purpose: To evaluate changes in median apparent diffusion coefficient (ADC) within metastatic oligoprogressing lesions from prostate cancer treated with stereotactic body radiotherapy (SBRT) and compa...

Best- and Worst-Case Scenario: Uncertainty Bounds Informed By Daily Scanning in Weekly CBCT-Based Accumulated Dose for Head and Neck Cancer

Authors: Peter Balter, Kristy K. Brock, Clifton David Fuller, Tze Yee Lim, James Long, Brigid A. McDonald, Androniki Mitrou, Andrew J. Schaefer, Stina Svensson

Affiliation: The University of Texas MD Anderson Cancer Center, RaySearch Laboratories, Rice University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: CBCT-based accumulated dose can provide up-to-date dose information on responding anatomy. To optimize resources, it is necessary to determine how many scans provide adequate information for ...

Biomechanically Informed Diagnostic-to-Synthetic CT Transformation for Expedited Radiation Therapy Planning

Authors: Liyuan Chen, Steve Jiang, Chenyang Shen

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center

Abstract Preview: Purpose: Delays in radiation therapy (RT) initiation caused by conventional CT simulation processes can hinder timely treatment delivery and patient outcomes. This study proposes a Virtual Treatment S...

Box-Prompt Zero-Shot Smart Segmentation in Radiation Oncology Using a SAM-Based Model: Smartsam

Authors: Kristen A. Duke, Samer Jabor, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia

Affiliation: St. Mary's University, The University of Texas San Antonio, UT Health San Antonio

Abstract Preview: Purpose:
The Segment Anything Model (SAM) is a foundational box-prompt-based model for natural image segmentation. However, its applicability to zero-shot 3D medical image segmentation, particularl...

Brain Vessel Segmentation and Tracking in Longitudinal Glioblastoma MRI Scans

Authors: Evan Calabrese, Edward Robert Criscuolo, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose: Glioblastoma (GBM) is the most common and aggressive form of brain cancer. Deformable image registration (DIR) is a powerful tool to compute anatomical changes in longitudinal MRI scans, whic...

CT-Free PET Imaging: Synthetic CT Generation for Efficient and Accurate PET-Based Planning

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
PET is used in radiotherapy workflows for accurate target delineation. However, a separate CT scan is typically required for attenuation correction in PET imaging and for registering PET-d...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Clinical Application of Biology-Guided Radiotherapy (BgRT) to Patient Having a Cardiac Implantable Electronic Device (CIED)

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Comparative Analysis of Nine Deep Learning Architectures for Variable Density Grappa 1H Magnetic Resonance Spectroscopy Imaging (MRSI) Reconstruction

Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang

Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Comparison of AI-Based and Ants for Longitudinal Deformable Image Registration in Head and Neck Cancer

Authors: Aditya P. Apte, Joseph O. Deasy, Jue Jiang, Nancy Lee, Sudharsan Madhavan, Nishant Nadkarni, Lopamudra Nayak, Harini Veeraraghavan, Wei Zhao

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To track early response to radiotherapy using digital twins, it is crucial to quantify tumor volume and mass changes. Traditional tumor detection methods, particularly in image registration, ...

Comparison of Respiratory Motion between 4D-MR and 4D-CT in Compression Belt Patients

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...

Comprehensive Assessment of Intra-Fractional and Inter-Fractional Motion in Intensity-Modulated Proton Therapy for Esophageal Cancer

Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin

Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: The purpose of this study was to investigate the interplay effect during intra-fractional motion and the effect of the robust optimization parameters for inter-fractional motion in the intens...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Construction and Application Study of a Deep Learning-Based Iscout-Guided Precision Radiotherapy Positioning Error Prediction Model for Breast Cancer

Authors: Fangfen Dong, Jiaming Li, Xiaobo Li, Weipei Wang, Zhixin Wang, Bing Wu, Benhua Xu, Yong Yang, Yifa Zhao

Affiliation: Department of Radiation Oncology, Fujian Medical University Union Hospital/Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematologi, Zhangpu County Hospital, School of Medical Imaging, Fujian Medical University

Abstract Preview: Purpose: To explore the construction and clinical application value of a deep learning-based positioning error prediction model, providing a reference for optimizing iSCOUT system-guided precision rad...

Contrast Volume Prediction Using CT Dose Metrics

Authors: Niki Fitousi, Anna Romanyukha, Stuart Utting

Affiliation: University Hospitals Dorset, Qaelum NV

Abstract Preview: Purpose:
For increased patient safety and with a focus on sustainability in the radiology department, efforts are being made to optimize contrast media usage. In this study, the possibility of util...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Deep Learning-Based Auto-Segmentation in Cervical High-Dose-Rate Brachytherapy with Clinical Considerations

Authors: Benjamin Haibe-Kains, Ruiyan Ni, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, University Health Network

Abstract Preview: Purpose: Accurate auto-segmentation for targets and organs-at-risk (OARs) using deep learning reduces the delineating time in radiotherapy. In high-dose-rate brachytherapy, specific clinical criteria ...

Developing a Comprehensive Multi-Modal Framework for Population-Scale Liver Volumetry: Insights and Predictive Models

Authors: Mustafa Bashir, Diana Kadi, Kyle J. Lafata, Jacob A. Macdonald, Mark Martin, Yuqi Wang, Marilyn Yamamoto

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Electrical and Computer Engineering, Duke University, Department of Radiology, Duke Unversity

Abstract Preview: Purpose: To develop a high-throughput, automated-data-interrogation pipeline for integrating imaging and clinical information to identify key determinants of liver volume (LV), enabling population-sca...

Development and Validation of a Scalable Radiomics Pipeline for Lung Cancer Research Using Clinical and Public Datasets

Authors: Pradeep Bhetwal, Yingxuan Chen, Wookjin Choi, Michael Dichmann, Adam Dicker, Rupesh Ghimire, Yevgeniy Vinogradskiy, Maria Werner-Wasik

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Radiomics has emerged as a powerful tool in medical research. However, the lack of standardized and reproducible pipelines limits its clinical adoption. This study developed a robust and scal...

Development of a Comprehensive Thoracic Re-Irradiation Database and Investigation of Time-Dependent Dose-Recovery Dynamics for Toxicity Modeling

Authors: Victoria Doss, Tsion Gebre, Rachel B. Ger, Esi A Hagan, Elaina Hales, Russell K Hales, Xun Jia, Heng Li, Dezhi Liu, Todd R. McNutt, Meti Negassa, Anas Obaideen, Tinker Trent, K. Ranh Voong, Cecilia FPM de Sousa

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: As cancer care advances, more patients require re-irradiation, yet evidence-based data is lacking. This study aimed to develop a thoracic re-irradiation database and explore time-dependent re...

Development of a Fast Quality Assurance Software Tool for Helical Online Adaptive Radiation Therapy

Authors: Guang-Pei Chen, Mi Huang, Haidy G. Nasief, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Recently, kV imaging has been integrated into the Accuray Radixact platform, facilitating online adaptive and scan-plan-treat workflows with helical delivery in the near future. In order to s...

Direct-to-Unit Dose Calculations for Stereotactic Radiosurgery on a C-Arm Linac with Modern on-Board Imaging Solutions

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...

Dual-Branch Attention-Driven Network for Enhanced Sparse-View CBCT Reconstruction Using Planning CT As Prior Knowledge

Authors: Xiaoyi Dai, Manju Liu, Weiwei Sang, Pulin Sun, Fan Xia, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Rihui Zhang

Affiliation: Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Current deep learning-based sparse-view CBCT reconstruction methods are prone to hallucinatory artifacts, as they rely on inferred image details that may not correspond to true anatomical ...

Dual-Domain Reconstruction Network for Nonstop Gated CBCT Imaging: Application in Respiratory Gating Ablative Radiotherapy for Pancreatic Cancer

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yabo Fu, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Boris Mueller, Huiqiao Xie, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gating ablative radiotherapy for pancreatic cancer accounts for tumor movement due to respiration and typically requires 5, 15, or 25 fractions. Pretreatment imaging verification is essential...

Dual-Modality Protoacoustic and Ultrasound Imaging for Real-Time Monitoring of Proton Therapy In Vivo

Authors: Kristina Bjegovic, Yong Chen, Lucia Rodriguez Gonzalez, Marti Roper, Liangzhong Xiang

Affiliation: University of California, Irvine, University of California Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is an increasingly popular cancer treatment due to its precision, enabled by the Bragg Peak (BP), which minimizes side effects. This profile necessitates in-patient localizatio...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Enhance Four-Dimension Cone-Beam Computed Tomography (4D-CBCT) from Sparse Views Using a Novel Deep Learning Model

Authors: Lei Ren, Jie Zhang

Affiliation: University of Maryland School of Medicine

Abstract Preview: Purpose: 4D-CBCT is valuable for imaging anatomy affected by respiratory motions to guide radiotherapy delivery. However, 4D-CBCT often has undersampled projections acquired in each respiratory phase ...

Enhancing CNN-Based Brain Metastasis Detection in MRI By Integrating Locoregional 3D Deformation Technique

Authors: Minbin Chen, Ke Lu, Kaizhong Shi, Chunhao Wang, Chuan Wu, Zhenyu Yang, Fang-Fang Yin, Jingtong Zhao

Affiliation: The First People's Hospital of Kunshan, Duke University, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, Department of Radiation Oncology, Duke Kunshan University

Abstract Preview: Purpose: MRI-based automatic detection of brain metastases is often challenged by the small size and subtle nature of metastases. This study aimed to develop a novel deep learning-based brain metastas...

Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Evaluating Deep Learning Models for Accurate Segmentation of GTV and Oars in MR-Guided Adaptive Radiotherapy for Pancreatic Cancer

Authors: Christopher G. Ainsley, Pradeep Bhetwal, Yingxuan Chen, Wookjin Choi, Vimal K. Desai, Karen E. Mooney, Adam Mueller, Hamidreza Nourzadeh, Yevgeniy Vinogradskiy, Maria Werner-Wasik

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: MR-guided adaptive radiotherapy (MRgART) has demonstrated improved outcomes for patients with pancreatic cancer. However, the time-consuming re-segmentation of targets and organs-at-risk (OAR...

Evaluating Dose Variability in Bladder Contouring for MR-Guided Prostate Cancer Radiotherapy

Authors: Emily Helen Hayes, Chihray Liu

Affiliation: University of Florida

Abstract Preview: Purpose: To evaluate dosimetric discrepancies in bladder dose calculations among rigid, deformed, and manual contouring methods in prostate cancer patients and assess dose variations resulting from bl...

Evaluating Longitudinal Amyloid Burden Related to Alzheimer’s Disease When Transitioning between PET β-Amyloid Radiotracers

Authors: Brecca Bettcher, Tobey J Betthauser, Bradley T Christian, Sterling Johnson, Lisette LeMerise, Max McLachlan, Andrew McVea, Dhanabalan Murali, Ali Pirasteh, Matthew Zammit

Affiliation: University of Wisconsin-Madison School of Medicine and Public Health and Waisman Center

Abstract Preview: Purpose: The radiotracer [18F]NAV4694 is a desirable alternative to [11C]PiB for measuring amyloid neuropathology related to Alzheimer’s disease (AD), possessing similar imaging characteristics and fa...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Dosimetric Variations from Anatomical Changes in Head and Neck Cancer Patients Treated with Intensity Modulated Proton Therapy

Authors: Chia-Lung Chien, Wen C. Hsi, Romy Megahed, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
The dosimetric variations induced by inter-fractional anatomical changes in intensity-modulated proton therapy could impact the clinic outcomes for head-and-neck (HN) cancer patients. This...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of Nodule Volume Accuracy with Deep Learning-Based Reconstructions on Cdznte Photon-Counting and Energy-Integrating CT

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĆ£o Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĆ­sica Gleb Wataghin

Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...

Evaluation of Proton Therapy Robustness for Thoracic Cancer Patients

Authors: Lordina Owusuwaa Oheneferewoo Asibey, Rachel B. Ger, Heng Li

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Howard University

Abstract Preview: Purpose: Treatment of cancer patients with proton therapy requires robust optimization applications to be able to provide adequate target coverage whiles sparing healthy tissues. Our goal was to evalu...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

Evaluation of a Commercially Available Solution for Dose Verification Using Daily AI Generated Pseudo-CT from CBCT.

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.

Methods: Dose calculations in water phan...

Evaluation of the Varian Truebeam Linac Matching Process: Before, during, and after the Commission

Authors: Edwin Quashie, Yun Wang

Affiliation: Indiana University Medical School, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: To provide a formal evaluation for the TrueBeam linac matching process before, during and after the commission of the newly installed TrueBeam linac which we want to match to an existing True...

Feasibility of Using 68ga-PSMA for Biology-Guided Radiotherapy (BgRT) Treatment

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Neil Desai, Aurelie Garant, Orhan Oz, Elizeva Phillips, Rameshwar Prasad, Chenyang Shen, Robert Timmerman

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: This study reports findings from the first-in-human imaging-only trial evaluating the feasibility of using the novel PET tracer 68Ga-PSMA-11 (Illuccix) to guide external beam radiotherapy on ...

Feasibility of Using a Convolutional Neural Network to Predict Physician Evaluation of Synthetic Medical Images

Authors: Sofia Beer, Menal Bhandari, Alec Block, Nader Darwish, Joseph Dingillo, Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Rajkumar Kettimuthu, Jason Patrick Luce, Ha Nguyen, John C. Roeske, George K. Thiruvathukal, Austin Yunker

Affiliation: Data Science and Learning Division, Argonne National Laboratory, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Computer Science, Loyola University of Chicago

Abstract Preview: Purpose: Artificial intelligence (AI) generated synthetic medical images are seeing increased use in radiology and radiation oncology. Physician observer studies are an ideal way to evaluate the usabi...

Foundation Models with Balanced Data Sampling Enhance Auto-Segmentation for Cardiac Substructures

Authors: Chloe Min Seo Choi, Nikhil Mankuzhy, Aneesh Rangnekar, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Cardiac substructure irradiation predisposes patients for poor outcomes in thoracic radiation therapy. A deep learning model was developed to segment the cardiac substructures invariant to co...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Gaze Angle Selection in Proton Therapy for Ocular Tumors with Machine Learning

Authors: Ling Chen, Alexei V. Trofimov, Yi Wang, Dufan Wu

Affiliation: Massachusetts General Hospital, MGH

Abstract Preview: Purpose:
Selecting gaze angles of the eye is an important part of set-up of proton therapy for ocular tumors, ensuring that the treatment beam could irradiate the tumor while maximally sparing impo...

Generating Brain Pseudo-CT from PET-Only Images Using Deep Learning Method

Authors: Pouya Azarbar, Nima Kasraie, Mahsa Shahrbabki Mofrad, Peyman Sheikhzadeh

Affiliation: UT Southwestern Medical Center, Shahid Beheshti University of Medical science, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences, Tehran University of Medical Science

Abstract Preview: Purpose: PET imaging become crucial in diagnosing and managing various diseases, but its key limitation is the lack of detailed anatomical information. Integrating CT-scans with PET images enhances cl...

Generating Synthetic Positron Emission Tomography from Computed Tomography Using Lightweight Diffusion Model for Head and Neck Cancer

Authors: Rashmi Bhaskara, Shravan Bhavsar, Ananth Grama, Oluwaseyi Oderinde, Shourya Verma

Affiliation: Purdue University

Abstract Preview: Generating Synthetic Positron Emission Tomography from Computed Tomography using Lightweight Diffusion Model for Head and Neck Cancer
Purpose: To generate synthetic PET tumor avidity segments direc...

Generation of Virtual Lung PET Images from CT Data Via Deep Learning for Accelerated Tumor Detection and Preliminary Diagnosis

Authors: Pouya Azarbar, Nima Kasraie, Peyman Sheikhzadeh

Affiliation: UT Southwestern Medical Center, Shahid Beheshti University of Medical science, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences

Abstract Preview: Purpose: Positron Emission Tomography (PET) is crucial for diagnosing and monitoring diseases due to its functional imaging capabilities. However, its high cost, significant radiation exposure, and li...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

Head and Neck Treatment Evaluation with Cone Beam Computed Tomotherapy

Authors: Varsha Jain, Jun Kang, Paul Sulivan, Kate E. Verma, Yevgeniy Vinogradskiy

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose:
Patients undergoing treatment for head and neck(H&N) cancers experience significant body contour changes throughout treatment. Body contour changes are due to tumor shrinkage, weight loss,...

High Resolution Head Motion Correction Based on Pilot Tone Signals – a Calibration-Free Method

Authors: Cheng-Chieh Cheng, Jeffrey P Guenette, Yajun Li, Bruno Madore, Lei Qin

Affiliation: Brigham and Women's Hospital, National Sun Yat-sen University, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Pilot tone (PT), a compact RF sensor, has been integrated into clinical practice for motion detection. Prior studies proposed mapping PT signals to head positions using a calibration step tha...

High-Temporal Dynamic CBCT Imaging Via Gaussian Neural Representation

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...

Image Quality Enhancement for Transrectal Ultrasound Imaging of Prostate Brachytherapy Using Deep Learning: A Needle Eraser

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Serdar Charyyev, Xianjin Dai, PhD, Yu Gao, Thomas R. Niedermayr, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Real-time transrectal ultrasound imaging is the gold standard for needle placement and treatment planning of real-time based-ultrasound-based high dose-rate (HDR) prostate brachytherapy. Cumu...

Immobilization and Optimization of Pulse Sequences for 0.23T MRI

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...

Improving Operational Efficiency in Head and Neck Proton Therapy through Adaptation Analysis

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey

Affiliation: Thompson Proton Center

Abstract Preview: Purpose: Proton therapy plans can be highly sensitive to both anatomical changes and positional errors, making the acquisition of Quality Assurance CT (QACT) images a routine clinical practice during ...

In-Vivo Dosimetry in Positron-Guided Radiation Therapy

Authors: Davide Brivio, Erno Sajo, Ryan Williams, Piotr Zygmanski

Affiliation: University of Massachusetts Lowell, Brigham and Women's Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: To develop a non-invasive 3D in-vivo dosimetry tool exploring the relationship between positron annihilations and dose per voxel using Monte Carlo simulation. The Positron Guided Radiation Th...

Innovative Workflow for Enhanced in-Vivo Dosimetry Using Gafchromic Film

Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...

Integrating Foundation Model with Self-Supervised Learning for Brain Lesion Segmentation with Multimodal and Diverse MRI Datasets

Authors: Zong Fan, Fan Lam, Hua Li, Rita Huan-Ting Peng, Yuan Yang

Affiliation: University of Illinois at Urbana Champaign, University of Illinois at Urbana-Champaign, Washington University School of Medicine, University of Illinois Urbana-Champaign

Abstract Preview: Purpose: Accurate lesion segmentation in MRI is critical for early diagnosis, treatment planning, and monitoring disease progression in various neurological disorders. Cross-site MRI data can alleviat...

Integrating Multiple Modalities with Pretrained Swin Foundation Model for Head and Neck Tumor Segmentation

Authors: Jue Jiang, Aneesh Rangnekar, Shiqin Tan, Harini Veeraraghavan

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Weill Cornell Graduate School of Medical Sciences

Abstract Preview: Purpose: Clinicians often use information from FDG-PET and CT to interpret and delineate gross tumor (GTVp) and nodal (GTVn) volumes for radiotherapy planning in head and neck (HN) cancer patients. He...

Investigating CT-Based Lung Ventilation Heterogeneity As a Biomarker for COPD Severity

Authors: Shiho Amster, Ryan Andosca, Igor Barjaktarevic, Michael Vincent Lauria, Daniel A. Low, Dylan P. O'Connell, Ann Raldow, Brad Stiehl

Affiliation: Department of Pulmonology, University of California Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Image-based biomarkers could be useful for disease diagnosis and prognosis, especially in heterogeneous lung diseases like COPD. The purpose of this study is to assess the feasibility of usin...

Investigating Racial Differences in 68ga-PSMA-11 PET/CT Imaging for Patients with Biochemical Recurrence after Radical Prostatectomy: Preliminary Findings

Authors: Maya Ataya, Clint Bahler, Ramotallah Dami Jubril, Michael Koch, Oluwaseyi Oderinde, Mark Tann

Affiliation: Purdue University, epartment of Urology, Indiana University School of Medicine, Department of Urology, Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indiana University School of Medicine

Abstract Preview: Purpose:
To investigate racial differences in the detection of biochemical recurrence (BCR) using 68Ga-PSMA-11 PET/CT, known for its improved sensitivity and specificity in patients after radical p...

Investigating the Use of a DWI Phantom for Routine QA of an MR-Linac at Room Temperature

Authors: Nicholas Carlson, Joel J. St-Aubin

Affiliation: University of Iowa Hospitals and Clinics, University of Iowa

Abstract Preview: Purpose: To establish baselines metrics and determine longitudinal accuracy and reproducibility of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) values for a 1.5T Elekta Un...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our ā€œped...

Investigation of Low Iodine Concentration Detectability of Dual-Energy CT Imaging Using a Customized 3D Printed Phantom

Authors: Michalis Aristophanous, Laura I. Cervino, Maria F. Chan, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Y Lee, Xiang Li, Seng Boh Gary Lim, Usman Mahmood, Jean M. Moran, Jason Ocana

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To determine the limits of iodine concentration detection (LOD) and quantification (LOQ) in dual-energy computed tomography using a 3D printed phantom while considering different background, ...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Lung Nodule Volume Estimation: Performance of Conventional Energy-Integrating and Cdznte-Photon-Counting CT Using Hybrid Reconstruction Method

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĆ£o Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĆ­sica Gleb Wataghin

Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...

Management of 4D CBCT Dose for Patients with Implanted Cardiac Devices

Authors: Won Chang, Vadim L. Stakhursky, Yevgeniy Vinogradskiy

Affiliation: Jefferson Einstein, Alliance Cancer Specialists, Thomas Jefferson University

Abstract Preview: Purpose: 4DCBCT is a powerful tool for localization of moving targets when treating lung tumors with hypofractionated regimens (SBRT). However, for patients with implanted cardiac devices (ICD) in clo...

Mesial Temporal Tau-PET Is Related to Diffusion Tensor Imaging Outcomes in Adults with Down Syndrome

Authors: Andrew Alexander, Brecca Bettcher, Bradley T Christian, Jose Guerrero-Gonzalez, Steven Kecskemeti, Lisette LeMerise, Max McLachlan, Andrew McVea, Matthew Zammit

Affiliation: University of Wisconsin-Madison School of Medicine and Public Health and Waisman Center

Abstract Preview: Purpose: Individuals with Down syndrome (DS) develop Alzheimer’s Disease (AD) with very high prevalence (>90%). Neuropathology includes amyloid plaque (Aβ) accumulation, followed by neurofibrillary ta...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Multi-Modality Artificial Intelligence for Involved-Site Radiation Therapy: Clinical Target Volume Delineation in High-Risk Pediatric Hodgkin Lymphoma

Authors: Tyler J Bradshaw, Sharon M Castellino, Steve Y Cho, David Hodgson, Bradford S Hoppe, Kara M Kelly, Andrea Lo, Sarah Milgrom, Xin Tie

Affiliation: Department of Radiation Oncology, University of Toronto, Department of Radiology, University of Wisconsin, University of Colorado Anschutz, Department of Medical Physics, University of Wisconsin, Department of Radiation Oncology, Mayo Clinic, Department of Radiation Oncology, BC Cancer, Vancouver Center, Department of Radiology, University of Wisconsin - Madison, Roswell Park Comprehensive Cancer Center, Emory University School of Medicine

Abstract Preview: Purpose: Clinical target volume (CTV) delineation for involved-site radiation therapy (ISRT) in Hodgkin lymphoma (HL) is time-consuming due to the need to analyze multi-time-point PET/CT scans co-regi...

Multi-Organ Segmentation of Pelvic Cone-Beam Computed Tomography (CBCT) with Transformer Models to Enhance Adaptive Radiotherapy for Prostate Cancer

Authors: Ming Chao, Thomas Chum, Tenzin Kunkyab, Yang Lei, Tian Liu, Richard G Stock, Hasan Wazir, Junyi Xia, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose:
This study aims to develop effective strategies for multi-organ segmentation of pelvic cone-beam computed tomography (CBCT) images based on transformer models to facilitate adaptive radiat...

Nnae: Automating Anomaly Detection and Quality Assurance in Medical Image Segmentation

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
Deep learning-based automatic medical image segmentation is increasingly employed in clinical practice, significantly reducing manual workload. However, verifying segmentation results rema...

Optimal Choice of Companion Radiotracer for TAT 225Ac-Mti-201.

Authors: Vinay K Banka, Mikalai Budzevich, William R. Gibbons, Mark L. McLaughlin, Jacob Moriarty, Eduardo G. Moros, David L. Morse, Christopher J. Tichacek, Thad J. Wadas

Affiliation: Modulation Therapeutics Inc, Moffitt Cancer Center, University of Iowa

Abstract Preview: Purpose: A targeted alpha therapy drug, 225Ac-MTI-201, has been developed targeting the Melanocortin 1 Receptor for metastatic uveal melanoma and is currently in FIH clinical trials. Since alpha emiss...

Optimization of the U-Net Model for the Radiation Dose Prediction in Lung Cancer RT Plans and Its Uncertainty Quantification

Authors: Ibtisam Almajnooni, Victor Cobilean, Milos Manic, Harindra Sandun Mavikumbure, Elisabeth Weiss, Lulin Yuan

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: This study aims to optimize the 3D U-Net architecture for dose prediction in lung cancer radiation therapy (RT) plans, particularly in scenarios with limited clinical data, as well as to quan...

Optimizing Dose Coverage and Mitigating Electron Return Effects and Electron Stream Effects in MR-Linac Treatment of Extremity Malignancies: The Impact of Bolus and Gel Use

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Darren M. C. Poon, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study investigates optimal treatment strategies utilizing MR-linac for extremity lesions, with a specific focus on a 0.6 cm deep lesion in the right palm. The magnetic field-induced dose...

Optimizing Quality Assurance CT Frequency and Setup Uncertainty in Brain Proton Therapy Patients for Reduced Normal Tissue Dose

Authors: Rachel B. Ger, Heng Li, Anh Tran

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients undergo quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and utilize robustness scenarios for setup and range uncertainties. For intra...

Optimizing Quality Assurance CT Scan Frequency in Proton Therapy: Reducing Excess Dose While Maintaining Treatment Accuracy

Authors: Curtiland Deville, Rachel B. Ger, Heng Li, Todd R. McNutt

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients receive quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and determine adaptive therapy needs as proton treatments are highly sensitiv...

PET Imaging and Novel Cardiac Radiomics to Predict Pre-Radiotherapy Cardiac Conditions for Lung Cancer Patients Undergoing Radiotherapy.

Authors: Wookjin Choi, Michael Dichmann, Adam Dicker, Nilanjan Haldar, Yingcui Jia, Nicole L Simone, Eugene Storozynsky, Yevgeniy Vinogradskiy, Maria Werner-Wasik

Affiliation: Thomas Jefferson University, 9Department of Radiation Oncology, Thomas Jefferson University

Abstract Preview: Purpose: Cardiotoxicity remains a significant limitation for lung cancer patients treated with radiotherapy. Pre-radiotherapy cardiac conditions increase the probability of patients developing cardiot...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-Chacón, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Performance Comparison of Artificial Intelligence-Based Auto-Segmentation Software on Pediatric CT Image Datasets for the Creation of Patient Specific Computational Phantoms

Authors: Wesley E. Bolch, Emily L. Marshall, Dhanashree Rajderkar, Wyatt Smither

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the accuracy of TotalSegmentator, an AI-based automatic segmentation toolkit, on pediatric CT scans as the original software was trained on adult image datasets with a mean patie...

Portpy: An Open-Source Python Package to Accelerate Research in Radiotherapy Treatment Planning Optimization

Authors: Qijie Huang, Gourav Jhanwar, Saad Nadeem, Vicki Trier Taasti, Mojtaba Tefagh, Seppo Tuomaala, Masoud Zarepisheh

Affiliation: Varian Medical Systems Inc, Department of Clinical Medicine - Danish Center for Particle Therapy, Aarhus University Hospital, Memorial Sloan Kettering Cancer Center, The University of Edinburgh

Abstract Preview: Purpose:
We have developed PortPy (Planning and Optimization for Radiation Therapy in Python), a first-of-its-kind open-source package designed to accelerate research and development in radiotherap...

Prediction of Metastasis-Free Survival in Patients with Prostate Adenocarcinoma Using Primary Tumor and Lymph Node Radiomics from Pre-Treatment PSMA PET/CT Scans.

Authors: Ozan Cem Guler, William Silva Mendes, Sangbo Oh, Cem Onal, Lei Ren, Apurva Singh, Phuoc Tran

Affiliation: University of Maryland School of Medicine, Baskent University Faculty of Medicine, Department of Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: To predict metastasis-free survival (MFS) for patients with prostate adenocarcinoma treated with androgen deprivation therapy and external radiotherapy using clinical factors and radiomics ex...

Prior-Adapted Progressive Motion-Resolved CBCT Reconstruction Using a Dynamic Reconstruction and Motion Estimation Method

Authors: Hua-Chieh Shao, You Zhang, Ruizhi Zuo

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cone-beam CT (CBCT) provides on-board patient anatomy for image guidance and treatment adaptation in radiotherapy. However, to compensate for respiration-induced anatomical motion, motion-res...

Prospective Organ-Level Dose Estimation in CT Imaging Using Scout-Net: A Comparison with Established Methods

Authors: Maria Jose Medrano, Grant Stevens, Liyan Sun, Justin Ruey Tse, Adam S. Wang, Sen Wang

Affiliation: Department of Radiology, Stanford University, GE HealthCare, Stanford University

Abstract Preview: Purpose: Patient exposure to ionizing radiation is a major concern in CT imaging. Size-specific dose estimation methods can prospectively estimate organ-level radiation doses based on patient sizes an...

Python-Native Cerr for Cloud-Based Medical Image Analyses

Authors: Aditya P. Apte, Joseph O. Deasy, Sharif Elguindi, Aditi Iyer, Jue Jiang, Eve Marie LoCastro, Jung Hun Oh, Amita Shukla-Dave, Harini Veeraraghavan

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: We present port of popular Computational Environment for Radiological Research software platform to Python programming language to cater to cloud-based analyses.
Methods: The components of...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

Quantitative Analysis of Three Strategies for CTPA Scan Timing Optimization

Authors: Zahra Alyani Nezhad, Carrie Bartels, Rachel Bladorn, Sean D. Rose, Kelsey Schluter, Timothy P. Szczykutowicz

Affiliation: Departments of Radiology and Medical Physics, University Wisconsin-Madison, University of Wisconsin Madison, University of Wisconsin-Madison, University of Texas at Houston Medical School, University of Wisonsin-Madison

Abstract Preview: Purpose: Pulmonary embolism is a life-threatening condition, and computed tomography pulmonary angiography (CTPA) is the gold standard for diagnosis. Inadequate contrast enhancement often leads to a h...

Radiopharmaceutical-Free Assessment of Tumor Vasculature Condition in Particle Therapy By Means of Range-Verification PET: A Feasibility Rat Study

Authors: Go Akamatsu, Han Gyu Kang, Chie Seki, Hitomi Sudo, Hideaki Tashima, Chie Toramatsu, Hidekatsu Wakizaka, Iwao Yamaya, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose:
Tumor oxygen status, which provides important information to optimize particle therapy, may constantly change during a treatment period of several weeks. However, it is impractical to perf...

Reconstructing Radiopharmaceutical Distributions Using Coded Aperture Tomography with Photon Counting Detector

Authors: David P. Adam, Xun Jia, Youfang Lai, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Radiopharmaceutical therapy is experiencing a resurgence in interest due to its potential of treating widespread metastatic disease in a patient-specific manner. Accurately measuring and desc...

Repeatability of Quantitative 3D T1ρ Imaging in Head and Neck Cancer

Authors: Sandeep Panwar Jogi, Nancy Lee, Ricardo Otazo, Ramesh Paudyal, Qi Peng, Akash Shah, Amita Shukla-Dave, Can Wu

Affiliation: Department of Radiology, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiology, Albert Einstein College of Medicine and Montefiore Medical Center

Abstract Preview: Purpose: Quantitative T1ρ imaging provides enhanced tissue characterization beyond standard T1 and T2 parameters, potentially supporting early-stage longitudinal monitoring of head and neck cancer. Th...

Retrospective Analysis of Shape and Dosage Changes in Structures during Radiotherapy for Head and Neck Cancer Patients Based on Velocity

Authors: Daming LI, Jinsen Xie, Zhe Zhang

Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China

Abstract Preview: Purpose: To analyze the actual doses received during radiotherapy for head and neck cancers (HNC) using Velocity, providing insights for adaptive radiotherapy decision-making.
Methods: Thirty-three...

Sensitivity of CT Ventilation Imaging to Image Acquisition and Reconstruction Parameters: A Phantom Study

Authors: Hilary Louisa Byrne, Paul J. Keall, John Kipritidis, Jeremy Lim

Affiliation: Northern Sydney Cancer Centre, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose:
Non-contrast CT ventilation imaging (CTVI) has been developed as a cost-effective and accessible alternative to PET/SPECT V/Q imaging for visualizing lung function. However, the sensitivit...

Shape-Optimized Radiation-Induced Acoustic Computed Tomography for In Vivo online Monitoring of Radiation Therapy

Authors: Yong Chen, Gilberto Gonzalez, Omprakash Gottam, Liangzhong Xiang

Affiliation: University of California, Irvine, Koneru Lakshmaiah Education Foundation, University of Texas at San Antonio., University of Oklahoma Health Science Center

Abstract Preview: Purpose: Clinics currently lack techniques for real-time, in vivo monitoring of radiation therapy (RT), which is desirable for precise treatment. Radiation-induced acoustic computed tomography (RACT) ...

Simplified Method of Assessing Lung Volume Limits during the Planning Process in the Re-Treatment Environment

Authors: Sameera Kumar, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose:
Difficulty assessing lung limits during treatment planning in the retreatment environment can be compounded as limits are volume-based (ie. VxGy<37%) and require a critical volume with a m...

Slit Scanning Delivery Simulation for Flash Radiotherapy

Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Supercomputing-Enabled CT Virtual Imaging Trials: A Population-Scale Pilot Study

Authors: Ehsan Abadi, Zakaria Aboulbanine, Nicholas D Felice, David Fenwick, Anuj J. Kapadia, Cindy Marie McCabe, Jayasai Ram Rajagopal, Ehsan Samei

Affiliation: Duke University, Oak Ridge National Laboratory, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose:
Virtual imaging trials (VITs) offer a computational alternative to clinical imaging trials leveraging virtual patients, scanners, and interpreters to assess imaging questions. To provide m...

Teach What You See: Incorporating Theranostics Curriculum into Medical Physics Resident Education

Authors: Isaac J. Bailey, Lindsay S. DeWeese, Anna M. Mench, Celeste Winters

Affiliation: Oregon Health & Science University, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: The emergence and recent FDA approval of several new radiopharmaceutical therapies have increased demand for physicists to provide specialized support. However, these topics are not yet inclu...

The Unspoken Impact of Couch Sag on Breathing-Traces Collected during Patient Simulation

Authors: Giorgi Archuadze, William P. Donahue, David Kanchaveli, Shih-Chi Lin, Sebastian Meyer, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Breathing traces captured at simulations are often used for deep-inspiration breath-hold (DIBH) treatments. However, systematic drift can occur in the traces that is unrelated to the patients...

Time-Resolved CBCT: A Novel Solution for Motion Management

Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang

Affiliation: The University of Chicago

Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...

Tin-Filtered Spectral Shaping Technique in Clinical Photon-Counting CT: Impact on Noise Magnitude By Object Size, Radiation Dose, and Spectral Reconstruction Type

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate how tin-filtered spectral shaping in clinical photon-counting computed tomography (PCCT) affects noise magnitude across varying object sizes, radiation doses, and spectral reconst...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...

Towards Real-Time Radiotherapy Monitoring By Cherenkov Imaging: Applications of Patient-Specific Bio-Morphological Features Segmented Via Deep Learning

Authors: Petr Bruza, Yao Chen, David J. Gladstone, Lesley A Jarvis, Brian W Pogue, Kimberley S Samkoe, Yucheng Tang, Shiru Wang, Rongxiao Zhang

Affiliation: NVIDIA Corp, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri, University of Wisconsin - Madison

Abstract Preview: Purpose: Cherenkov imaging provides real-time visualization of megavoltage radiation beam delivery during radiotherapy. Patient-specific bio-morphological features, such as vasculature, captured in th...

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...

Validation of Synthetic CT-Based Online Monitoring for Adaptive Proton Therapy

Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...