Search Submissions 🔎

Results for "pixel 6mm": 39 found

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A Real-Time Framework for Fiducial Tracking and Intrafraction Motion Assessment of Cyberknife in Stereotactic Body Radiation Therapy for Liver Cancer

Authors: Ruiyan Du, Mingzhu Li, Ying Li, Wei Liu, Shihuan Qin, Yiming Ren, Biao Tu, Hui Xu, Lian Zhang, Xiao Zhang, Zengren Zhao

Affiliation: Department of General Surgery, Hebei Key Laboratory of Colorectal Cancer Precision Diagnosis and Treatment, The First Hospital of Hebei Medical University, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Mayo Clinic, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Fiducial tracking is widely used in CyberKnife to dynamically guide the gantry for moving target like liver cancer stereotactic body radiation therapy (SBRT). This study developed a robust fr...

An Adaptive Non-Local Means Filtering Method for Denoising CBCT Images Under Low X-Ray Fluence Conditions

Authors: Cem Altunbas, Farhang Bayat

Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic

Abstract Preview: Purpose:
Low dose imaging and scatter rejection hardware in CBCT reduces X-ray fluence incident on the imager, increasing noise, causing photon starvation artifacts in CBCT images. In this work, we...

Application of a Conditional Diffusion Model to Improve Real-Time MR Imaging in Online Adaptive MR-Guided Radiotherapy

Authors: Hideaki Hirashima, Haruo Inokuchi, Nobutaka Mukumoto, Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao, Keiko Shibuya, Linna Zhang

Affiliation: Kyoto University, Osaka Metropolitan University

Abstract Preview: Purpose:
To transform the quality of 2D cine MR images acquired during online adaptive MR-guided radiotherapy (OA-MRgRT) by utilizing a conditional diffusion model to achieve image quality comparab...

Assessment of the Quantum-CMOS Image Sensor for Use in Cherenkov Imaging during Radiation Therapy

Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue

Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Cherenkov imaging is a powerful tool for localizing entrance and exit dose during radiotherapy treatment. The current implementation uses an intensified-CMOS (iCMOS) camera allowing for high-...

Asymmetrical High Performance Brain Dedicated PET System: Design Optimization and Performance Evaluation

Authors: Yuemeng Feng, Hamid Sabet

Affiliation: Massachusetts General Hospital, Harvard Medical School

Abstract Preview: Purpose: We propose a novel brain-dedicated PET system comprising elliptical cylinder with a neck cut-out, supplemented by front and back panels to improve sensitivity and line-of-response sampling. T...

Automated Quantitative Method for Source Position Calculation in Annual Quality Assurance of High Dose Rate Brachytherapy Gynecological Applicators

Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...

BEST IN PHYSICS IMAGING: Volumetric Sampling Properties of Longitudinal Multiple X-Ray-Source Array Computed Tomography (MXA-CT)

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...

Characterization of Linear Energy Transfer Spectra in Mini Beam Spatially Fractionated Proton Therapy

Authors: Serdar Charyyev, Kaan Dere, Edgar Gelover, Mohammad Khurram Khan, Liyong Lin, Mark McDonald, Cristina Oancea, Alexander Stanforth, Sibo Tian, Suk Whan (Paul) Yoon, Mingyao Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Advacam

Abstract Preview: Purpose: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) utilizes physical collimators with apertures to generate minibeams, creating alternating regions of high-d...

Comparison Analysis of Three Kind of Solutions for Head and Neck Cancer VMAT Verification

Authors: Wenwen Bai

Affiliation: The Fourth Hospital of Hebei Medical University

Abstract Preview: Purpose: To compare three kind of solutions (EDR2 Film, MatriXX, COMPASS) for VMA quality assurance at head and Neck in Monaco plannig system.
Methods: Monacao 5.1 planning system optimazed 10 case...

Contrast-Dependent Loss of Edge Sharpness in Low-Contrast Targets with Increasing Iterative Reconstruction Strength

Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...

Deep Learning-Based Fast CBCT Imaging with Orthogonal X-Ray Projections for Gynecological Cancer Radiotherapy

Authors: Beth Bradshaw Ghavidel, Chih-Wei Chang, Yuan Gao, Priyanka Kapoor, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Jill Remick, Justin R. Roper, Zhen Tian, Xiaofeng Yang

Affiliation: Whinship Cancer Institute, Emory University, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Current cone-beam computed tomography (CBCT) typically requires no less than 200 degrees of angular projections, which prolongs scanning time and increases radiation exposure. To address thes...

Deep-Dive Comparative Assessment between Digitally Reconstructed Radiographs and X-Ray Digital Radiographs from Lung CT Scans

Authors: Xinyi Fu, Dan Ruan, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Digitally reconstructed radiographs (DRRs) are easy to generate and widely used to establish research protocols in pulmonary diagnosis and image-guided radiotherapy tasks. A question remai...

Design of Next Generation Hemispherical Brain PET System Aiming for 1mm Resolution

Authors: Go Akamatsu, Yuma Iwao, Kurumi Narita, Hideaki Tashima, Taiga Yamaya, Eiji Yoshida

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In brain positron emission tomography (PET), higher spatial resolution is better for visualizing detailed structures such as small nuclei and the layered structure of the cerebral cortex. The...

Developing a Physiological Carotid Artery Phantom and Verifying a Bayesian Geometric Calibration Method for Extended Field-of-View Interventional CBCT Artery Imaging

Authors: Mohammed Alzaabi, Owen Thomas Dillon, Julia Johnson, Andrew Kanawati, Tess Reynolds, Ann Yan

Affiliation: Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Khalifa University

Abstract Preview: Purpose: To develop a physiological carotid artery phantom and Bayesian geometric calibration method to examine the feasibility of extended field-of-view interventional CBCT artery imaging using a mul...

Development of Sphere Phantoms for Quantitative Evaluation of Computed Tomography Systems Resolution

Authors: Hyo-Min Cho, Changwoo Lee

Affiliation: Korea Research Institute of Standards and Science

Abstract Preview: Purpose: We develop sphere phantoms to assess spatial resolution of computed tomography (CT) systems and validate its usability using table-top X-ray experiment systems.
Methods: We manufactured sp...

Development of a Cadmium Zinc Telluride (CdZnTe) Detector-Based Neutron Imaging System

Authors: Soo Hyun Byun, Troy Farncombe, Edcer Jerecho DC Laguda

Affiliation: McMaster University

Abstract Preview: Purpose: We present the adaptation of a Cadmium Zinc Telluride (CdZnTe) detector, initially designed for SPECT-MR applications, to neutron imaging. This study explores a novel technique that utilizes ...

Direct Table Rotational Isocenter Determination Using Radiation Isocenter

Authors: Christopher Ackerman, Chang Chang, Yansong Liu, Stephen Kenneth Northway, Bailey Vallejo

Affiliation: University of California San Diego / California Protons, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose: To determine mechanical isocenter of a 6-degree-of-freedom (6DOF) couch using radiation isocenter. Coincidence between the isocenters is quantified using MyQA Phoenix amorphous silicon detect...

Dosimetric Impact of Calculation Grid Size in ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZAP-X is the newest cranial stereotactic radiosurgery (SRS) platform. Small-volume structures usually found in the head and neck may be susceptible to dose-volume averaging, which has not bee...

Feasibility of a Bench-Top Pcct Model for Electronic Density Measurements: A Monte Carlo Simulation Study

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Renan Felix dos Santos, Gustavo Freire Pereira da Silva, Alessandra Tomal

Affiliation: University of São Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin

Abstract Preview: Purpose: Evaluate the feasibility of a bench-top PCCT using Geant4 Monte Carlo simulations. The study applied the Geant4 framework on determining the electronic density of materials as a function of C...

First in-Vivo Proton Radiography Experiments for an Image-Guided Small Animal Irradiation Platform with a TimePix3-Based Detector Setup

Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl

Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam

Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.

Methods:...

Getting in Focus: Review of Current Focal Spot Size Testing Methods with Flat Panel Digital Radiography Detectors

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose:
Historically film has been the gold standard receptor for measurements of x-ray tube focal spot size. Flat Panel Digital Radiography Detectors (FPDRDs) have lower spatial resolution compar...

High-Temporal Dynamic CBCT Imaging Via Gaussian Neural Representation

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...

Impact of Lung Density on Plan Quality and Delivery Parameters in Lung Stereotactic Body Radiation Therapy (SBRT) Plans

Authors: David Chighvinadze, Indra J. Das, Jeremy D. Donaghue, Kevin Stephans, Gregory Videtic, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic, Cleveland Clinic Sandusky, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Cleveland Clinic Fairview

Abstract Preview: Purpose:: Evaluate the impact of lung density variations on plan quality and delivery parameters in lung SBRT Plans.
Methods: For a hypothetical case with a real patient anatomy, three GTVs with vo...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Improving Quantitative Accuracy of Maximum-a-Posteriori Expectation Maximization Reconstruction By Optimizing Gibbs Prior Parameters in SPECT

Authors: Krishnendu Saha

Affiliation: Cleveland Clinic Foundation

Abstract Preview: Purpose: The goal is to improve quantitative accuracy of a Maximum-a-posteriori expectation maximization (MAPEM) reconstruction of SPECT phantom images by optimizing Gibbs prior parameters.
Methods...

Integrating SPECT and Compton Imaging for Multi-Energy Photon Reconstruction

Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu

Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...

Long-Term Stability Assessment of an Imaging Ring System Using One Year of Monthly Quality Assurance Data

Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Monte Carlo Modeling of an Experimental X-Ray Fluorescence Computed Tomography (XFCT) System with a Pixelated CdTe Detector

Authors: Sang Hyun Cho, Sandun Y. Jayarathna, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To develop/validate a Monte Carlo (MC) model of an experimental benchtop x-ray fluorescence computed tomography (XFCT) system with a pixelated CdTe detector that can be used for MC simulation...

Quantitative Assessment of Iodine Detectability As a Function of Tissue Density, Thickness and Dose in Contrast-Enhanced Mammography

Authors: Jeffrey S. Nelson, Raj Kumar Panta, Megan K. Russ, Ehsan Samei

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Contrast-enhanced mammography (CEM) enhances tumor detection by utilizing energy-dependent information from iodinated contrast agents. However, there is a lack of quantitative techniques to a...

Quantitative Forward Modeling of Propagation-Based X-Ray Phase-Contrast Imaging at Clinical Scale

Authors: Giavanna Luisa Jadick, Patrick J La Riviere, Cailey Riggs

Affiliation: University of Chicago

Abstract Preview: Purpose: We explore the accuracy of physics models for propagation-based x-ray phase-contrast imaging (XPCI) with an eye to future clinical implementation, providing a practical assessment of detectio...

Rapid CBCT Imaging with Ultra-Sparse X-Ray Projections for Head & Neck Cancer Radiotherapy

Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...

Twin Table-Tilt Imaging: Rapid Metal Artefact Reduction Intraoperative CBCT Imaging during Pedicle Screw Spinal Fixation

Authors: Owen Thomas Dillon, Andrew Kanawati, Tess Reynolds

Affiliation: Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: Metal artefacts from implanted hardware and surgical tools remain a limitation for widespread adoption of intraoperative CBCT imaging. Gantry-based non-circular imaging trajectories have emer...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Use of Edge-Driven Modified Fuzzy C-Means Algorithm in DCE-MRI Image Sequences for Prostate Cancer Lesion Segmentation

Authors: Ilias Gatos, Stavros Grigoriadis, George C. Kagadis, Maria Karamesini, Paraskevi Katsakiori, Dimitris N. Mihailidis, Stavros Spiliopoulos, Efstratios Syrmas, Ioannis Theotokas, Stavros Tsantis, Pavlos Zoumpoulis

Affiliation: Diagnostic Echotomography, University of Pennsylvania, University of Athens, University of Patras

Abstract Preview: Purpose: To detect prostate lesions on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) images which is a particularly difficult task due to the heterogeneous and inconsistent representa...

Using Multiple Sequences MRI for Synthesizing CT Based on a Deep Learning Approach

Authors: Jie Hu, Nan Li, Chuanbin Xie, Shouping Xu, Xinlei Xu, Gaolong Zhang, Zhilei Zhang

Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, the First Medical Center of the People's Liberation Army General Hospital, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, Peopleʼs Republic of China, Department of Radiation Oncology, School of Physics, Beihang University, Beijing, 102206, Peopleʼs Republic of China

Abstract Preview: Purpose: This study aims to synthesize CT images for MRI-only radiation therapy using a deep learning approach that integrates information from the T1- and T2-weighted MRI sequence.
Methods: 97 hea...

Using a Generative Adversarial Network (GAN) for Source Particle Generation in Monte Carlo Radiation Therapy Simulations

Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions

Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...