Search Submissions 🔎

Results for "plane resolution": 47 found

3D Image Quality Evaluation of a New CT Scanner Employing 3D Landmark Scans, Super Resolution Reconstruction, and Ag Beam Filtration

Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White

Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ

Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...

A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

A Dual Energy CT-Guided Intelligent Radiation Therapy Platform

Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Assessing Dose Calculation Accuracy in Proton Plans Using Pin Ridge Filters

Authors: Zachary M. Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: High spatial resolution in pin ridge filter (pRF)-based proton planning may be constrained by the 1mm dose grid resolution in commercial treatment planning systems. This study investigates th...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Assessing Mlc Errors and Their Dosimetric Impact Delivered on Elekta Linear Accelerator from Two TPS Systems

Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...

Automated Treatment Planning for Linac-Based Stereotactic Radiosurgery of Intraocular Malignancies Via Hyperarc Knowledge-Based Planning

Authors: Chase Cochran, Shane McCarthy, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Manually generating intraocular stereotactic radiosurgery (SRS) plans involves significant challenges, including lengthy planning times and inter-planner variability. Knowledge-based SRS plan...

BEST IN PHYSICS ULTRASOUND: A Calibration Framework for Quantifying Element Misalignment in 2D Matrix Array Transducers Used in 3D Quantitative Ultrasound

Authors: Cristel Baiu, Laura Castaneda Martinez, Ivan M. Rosado-Mendez

Affiliation: University of Wisconsin, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: 2D matrix array transducers (2DMAT) are advancing volumetric ultrasound due to their ability to provide more isotropic 3D resolution, fast volumetric imaging, and highly customizable focusing...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Clinical Outcomes of Gamma Knife Stereotactic Radiosurgery Treatments for Intracranial Arteriovenous Malformations & Fistulas: A Single Institutional Retrospective Study

Authors: Madeleine Arbogast, David Dorndos, Denise E Foltz, Justin Fraser, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Neurosurgery, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: For stereotactic radiosurgery (SRS) treatments of intracranial arteriovenous malformations (AVM) and fistulas (AVF), same-day Leksell Gamma Knife (GK) is the preferred modality. Long-term cli...

Commissioning and Validation of a Commercially Available 3D Linear Stage Device for Gamma Knife Hdmm QA

Authors: Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: The objective of this study is to systematically evaluate and validate the performance of a commercially available 3D Linear stage device as a quality assurance (QA) tool to validate position...

Development of a High-Speed Digital Breast Tomosynthesis System with a Two-Dimensional Multiple X-Ray-Source Array

Authors: John M. Boone, Andrew M. Hernandez, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski

Affiliation: Johns Hopkins University, University of California, UT MD Anderson Cancer Center, University of New Mexico Albuquerque, UC Davis Health

Abstract Preview: Purpose: To significantly improve image quality relative to clinically deployed digital breast tomosynthesis (DBT) systems, which use a 1D acquisition geometry (an arc), with a 2D image acquisition ge...

Dosimetric Parameter Cross-Check Evaluations for Dedicated Biologically-Guided Radiotherapy Linac Using Two Water Phantom Systems

Authors: Nguyen Phuong Dang, Mason Hazlett, Lijun Ma, Yutaka Natsuaki, William T. Watkins, Zhengzheng Xu, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, Radiation Oncology, Keck School of Medicine of USC, RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: This is the first study reporting the beam dosimetric parameter cross-checks of Reflexion linac using different water phantom systems and detectors. The difference in measurements using diffe...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Enhancing T2-Weighted Brain MRI Resolution across Orientations Using AI-Based Volumetric Reconstruction

Authors: Mengqi Shen, Meghna Trivedi, Tony J.C. Wang, Andy (Yuanguang) Xu, Yading Yuan

Affiliation: Columbia University Medical Center, Dept of Med Hematology & Oncology, Data Science Institute at Columbia University, Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center

Abstract Preview: Purpose: T2-weighted (T2w) images are critical for identifying pathological changes due to their superior contrast in differentiating tissue types. However, they often lack detailed anatomical resolut...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Fast 3D Scintillation Dosimetry Using Single View Deep Learning Reconstruction

Authors: Louis Archambault, Nicolas Drouin, Alexis Horik, Simon Thibault

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de Physique, de Génie Physique et D'optique, et Centre d'optique, photonique et laser, Université Laval

Abstract Preview: Purpose: To develop a novel type of real-time 3D dosimeter for the quality assurance of linear accelerators used in external beam radiotherapy.
Methods: An experimental setup was constructed using ...

Feasibility Study of Ethos Artificial-Intelligence Online Adaptive Prostate SBRT

Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez

Affiliation: Hospital General Universitario Santa Lucia

Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

Foundation Model Guidance for CBCT-CT Image Registration in Radiotherapy

Authors: Hacene Azizi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Mohamed Lamine Seghier

Affiliation: Khalifa University Biomedical Engineering & Biotechnology, Laboratory of dosing, analysis and characterization in high resolution, Ferhat Abbas Setif 1 University, Khalifa University Physics Department, Khalifa University

Abstract Preview: Purpose:
To ensure accurate alignment of cone-beam computed tomography (CBCT) and computed tomography (CT) images for image-guided radiotherapy, this study evaluates a foundation model guidance fra...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Investigation and Machine-Learning Modeling of Dosimetric Discrepancies in Eclipse-Calculated Head and Neck Treatment Plans

Authors: Andres Portocarrero Bonifaz, Ian Schreiber

Affiliation: CARTI Cancer Center

Abstract Preview: Purpose: To explore how calculation grid resolution, along with other planning factors, affects head and neck dose calculation accuracy and contributes to potential discrepancies in the Eclipse Treatm...

Investigation of Prompt Gamma Imaging Using a Three Axis Rotating Compton Camera

Authors: Molokotima Kekana, Dennis S. Mackin, Stephen W. Peterson, Jerimy C. Polf

Affiliation: Department of Physics, University of Cape Town, M3D, Inc, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: To study the imaging characteristics of a prototype prompt gamma (PG) imaging system consisting of multiple rotating Compton cameras (CC).

Methods: The prototype CC imaging system is c...

Knowledge-Based Deep Residual U-Net for Synthetic CT Generation Using a Single MR Volume for Frameless Radiosurgery

Authors: Justus Adamson, John Ginn, Yongbok Kim, Ke Lu, Trey Mullikin, Xiwen Shu, Chunhao Wang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Duke Kunshan University

Abstract Preview: Purpose:
To develop a knowledge-based deep model for synthetic CT (sCT) generation from a single MR volume in frameless radiosurgery (SRS), eliminating the need for CT simulation prior to the SRS d...

Management of 4D CBCT Dose for Patients with Implanted Cardiac Devices

Authors: Won Chang, Vadim L. Stakhursky, Yevgeniy Vinogradskiy

Affiliation: Jefferson Einstein, Alliance Cancer Specialists, Thomas Jefferson University

Abstract Preview: Purpose: 4DCBCT is a powerful tool for localization of moving targets when treating lung tumors with hypofractionated regimens (SBRT). However, for patients with implanted cardiac devices (ICD) in clo...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Motion Correction-Driven Patient-Specific 2D Cine MRI-Based Dynamic Volumetric Reconstruction for MRI-Guided Radiotherapy Intra-Fractional Motion Monitoring

Authors: Karyn A Goodman, Yang Lei, Tian Liu, D. Michael Lovelock, Charlotte Elizabeth Read, Jing Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Real-time volumetric MRI is essential for precise motion management in MRI-guided radiotherapy (MRIgRT). While 2D Cine MRI offers high temporal resolution for motion tracking, it inherently l...

Non-Planar Narrow-Beam CT: Near Scatter-Free, High-Resolution Breast Imaging at Screening Mammography Doses.

Authors: Peymon Ghazi

Affiliation: MALCOVA Inc.

Abstract Preview: Purpose: To develop a near scatter‐free breast CT imaging system that expands coverage of the posterior breast anatomy and enhances contrast resolution for solid masses and microcalcifications, while ...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Precise Measurement of Leaf Open Time in Tomotherapy Using Advanced Plastic Scintillators

Authors: Marcos Feijoo, Mamoru Ichiki, Tatsuya Maeda, Tatsuhiro Makino, Tomonori Megumi, Tadashi Nakabayashi, Yukino Nakata, Shuichi Ozawa, Daishi Takayama

Affiliation: Hiroshima High-Precision Radiotherapy Cancer Center, Blue Physics LLC, Imamura General Hospital, Accuray Inc.

Abstract Preview: Purpose: This study aims to accurately measure the leaf open time (LOT) of the multi-leaf collimator (MLC) in tomotherapy using an advanced plastic scintillator detector (PSD) with high time resolutio...

Prior-Informed Neural Super-Resolution Dosimetry for Radiotherapy QA from Sparse Dosimeter Arrays

Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Quantitative 3D Surface Mapping of Cherenkov Images for Real-Time Beam Deviation Detection in Radiotherapy

Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone

Affiliation: Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Cherenkov images are two-dimensional projections of the surface light emissions, and lack spatial information about the radiotherapy beam delivery. We implement the first fusion of Cherenkov ...

Sentinel: Development and Implementation of an Automated, Passive Varian Log File and Treatment Plan Analysis

Authors: Leon Dunn

Affiliation: IsoAnalytics Pty. Ltd.

Abstract Preview: Purpose: The purpose of this work is to present the development and results of an automated Varian Trajectory Log file processing software platform called Sentinel (IsoAnalytics Pty. Ltd.).
Methods...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Standardized MRI-CT Hybrid Workflow for High-Dose-Rate Image-Guided Adaptive Brachytherapy in Cervical Cancer: Aapm TG-303 Implementation

Authors: Kim Creach, Kim Howard, Julius G. Ojwang, Richard A. Shaw, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: To present a standardized MRI-CT hybrid workflow for High-Dose-Rate (HDR) Image-Guided Adaptive Brachytherapy (IGBT) in cervical cancer, aligned with AAPM TG-303, as a model to assist with im...

Towards Penile Small Vessel Imaging with Ferumoxytol-Enhanced MRI

Authors: Darren Fang, Amar Kishan, Justin McWilliams, Dan Ruan, Xiaodong Zhong

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Department of Radiological Sciences, University of California, Los Angeles

Abstract Preview: Purpose: Prostate radiotherapy can malform penile vasculature, contributing to erectile dysfunction and compromising quality of life. To detect, quantify, and preferably avoid such occurrences, this p...

Transformer-Based Proton Dose Prediction with and without Diffusion Process

Authors: Jing Qian, Brandon Reber, David M. Routman, Satomi Shiraishi

Affiliation: Mayo Clinic

Abstract Preview: Purpose: The dose distribution in proton radiotherapy (PRT) is characterized by sharp gradients, posing a challenge for machine learning-based dose prediction. While denoising with diffusion processes...

Ultra-Sparse-View Cone-Beam CT Reconstruction Based Strictly-Structure-Preserved Deep Neural Network in Image-Guided Radiation Therapy

Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang

Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University

Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...