Search Submissions 🔎

Results for "pmc topas": 28 found

4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

BEST IN PHYSICS THERAPY: Fast and Convenient Proton Pencil Beam Energy QA with Multi-Layer Faraday Cup (MLFC)

Authors: Paul Boisseau, Eric S. Diffenderfer, Andrew Friberg, Wenbo Gu, Matthew Nichols, Kan Ota, Xiaokun Teng, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, Pyramid Technical Consultants, Inc., University of Pennsylvania

Abstract Preview: Purpose: Traditional quality assurance procedures for proton pencil beam energies involve water tank setups or multiple solid water phantoms and are time-consuming. This study demonstrates that an inn...

Backward Photon Monte Carlo Propagator (BPMCP): Proof of Concept of a Fully Physics-Driven SPECT Reconstruction

Authors: Alejandro Bertolet, Carlos Huesa-Berral, Victor V. Onecha

Affiliation: Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Radioembolization for liver tumors using 90Y microspheres uses SPECT as confirmatory dosimetry, although 90Y is a pure β-emitter, and SPECT-imaging is only available through subsequent bremss...

Characterization of Linear Energy Transfer Spectra in Mini Beam Spatially Fractionated Proton Therapy

Authors: Serdar Charyyev, Kaan Dere, Edgar Gelover, Mohammad Khurram Khan, Liyong Lin, Mark McDonald, Cristina Oancea, Alexander Stanforth, Sibo Tian, Suk Whan (Paul) Yoon, Mingyao Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Advacam

Abstract Preview: Purpose: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) utilizes physical collimators with apertures to generate minibeams, creating alternating regions of high-d...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Comparing SPECT Dose Reconstruction Algorithm Accuracy As a Function of Imaging Parameters

Authors: Srinivas Cheenu Kappadath, Brian Michael Kelley, Benjamin P. Lopez

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Imaging systems are subject to errors from finite spatial resolution and voxel size. This work demonstrates their effect on dose algorithm {Monte Carlo (MC), dose-volume kernel (DVK), and ...

Computational Prototype Single-Channel Vaginal Cylinder with Integrated Filter to Address Dose Uniformity in High-Dose-Rate Brachytherapy for Endometrial Cancer

Authors: Brett Bocian, Patrick James Jensen, Luis Augusto Perles, Christopher J. Tien

Affiliation: Yale University School of Medicine, University of Miami, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Guidelines for dose prescriptions in endometrial cancer are based upon depth from the cylinder, traditionally 5 mm or 0 mm (i.e., surface). There are no current single-channel vaginal cylinde...

Creation of Pass-through Proton Minibeams Using a Single Quadrupole Magnet

Authors: Abdullah A. Alshreef, Grant A. McAuley, Jerry D Slater

Affiliation: Loma Linda University Medical Center, Loma Linda University

Abstract Preview: Purpose: In this project we investigate the use of a single permanent magnet quadrupole to create pass-through proton minibeams suitable for potential clinical use and preclinical radiobiology experim...

Dosimetric Changes of Magnetic Control System to Improve Anatomy in Abdominal SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Chang-Sei Kim, Yeongoh Ko, Anna E. Rodrigues

Affiliation: Duke University, Chonnam National University, Duke University Medical Center

Abstract Preview: Purpose: Radiation induced toxicities in bowel remains a challenge for SBRT. Due to sharp dose falloffs, small displacements of the bowel can lead to meaningful dose reduction. Remote magnetic navigat...

Dosimetric Impact of Monte Carlo Physics Models in Electronic Brachytherapy Simulations

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Jan P. Seuntjens, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Princess Margaret Cancer Centre & University of Toronto, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta, Université Laval, Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University

Abstract Preview: Purpose: Low-energy X-ray beams used in electronic brachytherapy (eBT) pose unique dosimetric challenges due to high depth-dose gradients, material-dependent detector responses, and the absence of sta...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

GPU Accelerated Monte Carlo Simulation for Tset Dose Calculation

Authors: Veng Jean Heng, Jan P. Seuntjens, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Princess Margaret Cancer Centre & University of Toronto, University of Pennsylvania

Abstract Preview: Purpose: We have developed a GPU-accelerated Monte Carlo (MC) simulation to determine the cumulative dose distribution of patients undergoing Total Skin Electron Therapy (TSET) using the Stanford tech...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Impact of Physics Modeling on Monte Carlo Normal Tissue Dose Reconstructions for Passive Scattering Proton Therapy Patients

Authors: Caroline Esposito, Keith T Griffin, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock

Affiliation: East Carolina University, University of Michigan, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: The National Cancer Institute’s Pediatric Proton and Photon Therapy Comparison Cohort aims to collect and analyze data from cancer centers across the United States and Canada to quantify diff...

Improvements from Monte Carlo Simulations over Pencil Beam Algorithms for Normal Tissue Dose Reconstruction in Proton Therapy Patients

Authors: Amy Berrington de Gonzalez, Keith T Griffin, Jae Won Jung, Cari M Kitahara, Choonik Lee, Choonsik Lee, Aimee L McNamara, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock

Affiliation: University of Michigan, East Carolina University, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School, Institute of Cancer Research

Abstract Preview: Purpose: Radiotherapy dose reconstruction enables retrospective epidemiological studies that connect late health effects to the organ-absorbed radiation doses received during treatment. Though clinica...

MC-Dolce: Monte Carlo-Based System for Dose and Linear Energy Transfer Calculations Engine for Carbon-Ion Radiotherapy

Authors: Min Cheol Han, Jin Sung Kim, Seok Ho Lee, Gahee Son, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: This study aims to develop the MC-DOLCE, a Monte Carlo (MC)-based system capable of calculating physical and biological dose distributions, as well as linear energy transfer (LET) distributio...

Monte Carlo Simulation of Dose Perturbations in HAM Applicator HDR Brachytherapy Treatments

Authors: Sam Beddar, Brett Bocian, David B. Flint, Benjamin Abraham Insley, Patrick James Jensen, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Reza Reiazi, Gabriel O. Sawakuchi

Affiliation: University of Miami, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Empyrean Medical Systems, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The Harrison-Anderson-Mick (HAM) applicator is an Ir-192 High-Dose-Rate (HDR) intraoperative radiotherapy device. It features a silicone body with embedded catheters that guide the Ir-192 sou...

Monte Carlo Simulation of Surface Radiation Dose for Cherenkov Imaging: Comparison with Commissioning Data for Truebeam and Halcyon

Authors: Hongjing Sun, Weibing Yang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to compare the commissioning results of TrueBeam and Halcyon linear accelerators with Monte Carlo (MC) simulations conducted using TOPAS. The ultimate goal is to leverage MC s...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Real-Time Proton and Carbon Ion Monte Carlo Dose Calculation through GPU-Acceleration and DL-Based Denoising Algorithms

Authors: Yankui Chang, Shijun Li, Xi Pei, Ripeng Wang, Xuanhe Wang, X. George Xu, Qing Zhang, Jingfang Zhao

Affiliation: University of Science and Technology of China, Shanghai proton and heavy ion center, School of Nuclear Science and Technology, University of Science and Technology of China, Anhui Wisdom Technology Co., Ltd.

Abstract Preview: Purpose:
This paper describes disruptive methods using both GPU-based MC simulation and deep-learning (DL)-based MC denoising algorithms, as well as clinical tests involving more than 560 patient p...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

The Topas Monte Carlo Framework – Status and Outlook after 15 Years of Development

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Thongchai Masilela, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin

Affiliation: University of California San Francisco, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital

Abstract Preview: Purpose: To present the results of 15 years of developments of the TOPAS TOol for PArticle Simulation framework, and to highlight recent and new developments.

Methods: Fundamental understanding...

Topas-Nbio – Status and Outlook after a Decade of Developments

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Kathryn D Held, Nicolas Henthorn, Jay LaVerne, Thongchai Masilela, Stephen J. McMahon, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin, Michael Taylor, John Warmenhoven

Affiliation: Massachusetts General Hospital, Queen's University Belfast, Massachusetts General Hospital and Harvard Medical School, University of California San Francisco, University of Manchester, Notre Dame University

Abstract Preview: Purpose: TOPAS-nBio brings a cutting-edge Monte Carlo (MC) simulation framework to the research community to test hypotheses of radiation effects at the nanometer/cell scale. Here, we present the deve...

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...