Search Submissions πŸ”Ž

Results for "post shift": 30 found

A Framework for the Standardization of Radiomics Classes in the Presence of Blur and Noise

Authors: Huay Din, Grace Jianan Gang, Grace Hyun Kim, Michael F. McNitt-Gray, Joseph W. Stayman, Yijie Yuan

Affiliation: Johns Hopkins University, John Hopkins University, University of Pennsylvania, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose:
Radiomics rely on quantitative features to discern underlying biological signatures. However, feature dependence on the imaging systems themselves hampers the creation of reproducible and ...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

Assessing the Impact of Intrafraction Shifts on Critical OAR Doses in a Standardized Spine SBRT Program

Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann

Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania

Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...

Assessment of the Auto Registration Feature of the PET/CT Linac Used for Biology Guided Radiation Therapy (BGRT)

Authors: Emily Hansen, Tyler Kaulfers, Alois M. Ndlovu, Francia Romero, Niara Rowe, Roland Teboh

Affiliation: Montefiore Einstein University Hospital, Hackensack University Medical Center

Abstract Preview: Purpose: Daily use and reliance on the auto registration feature requires a performance check. Clinical application of auto registration is performed without a selected region of interest (ROI), requi...

Automated Tool for Radiotherapy Initial Patient Setup: A Robust Approach Based on Vertebral Identification

Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute

Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...

Brain Structural Covariance Networks in Nicotine-Dependent Users: A Graph Analysis

Authors: Humberto Monsivais, Brian A. Taylor, Francesco Versace

Affiliation: Purdue University, Department of Behavioral Science, Division of Cancer Prevention and Population Sciences, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To identify possible signatures of altered brain morphometry in nicotine-dependency via a structural covariance network approach.

Methods: Fifty-one healthy controls (HC:27M, mean age=...

CBCT and Exactrac Dynamic Agreement for Patient Positioning during Spine SRS/SBRT Treatments

Authors: Martha J. Malin, Matthew Schelin

Affiliation: NYU Langone Health

Abstract Preview: Purpose: To evaluate the agreement between ExacTrac Dynamic (ETD) and CBCT-based positioning for spine SRS/SBRT treatments during initial patient setup and repositioning after intrafraction motion.

Comparison Study of Shift Frequency and Magnitude By Prostate Fiducial Tracking System: Triggered Image and Calypso

Authors: David J. Carlson, Yiu-Hsin Chang, Zhe (Jay) Chen, Hyosung Cho, Dae Yup Han, MinYoung Lee, Weili Zhong

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose:
To compare the intra-fractional motion tracking sensitivity of prostate fiducial markers using triggered imaging and calypso tracking for prostate cancer cases.
Methods:
This study w...

Design of Filtimator (Filter + Collimator) for CBCT of Pediatric Cancer Patients Receiving Proton Therapy

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...

Development of a Quantitative Surface Mapping Analysis Framework Involving a Robust Mask Removal Algorithm for Improved Objective Patient Setup Assessment in Head and Neck Intensity Modulated Proton Therapy

Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Michael H. Shang, Stephen Shang, Timothy R Williams

Affiliation: South Florida Proton Therapy Institute, SFPRF, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose:
Daily image guidance for head and neck intensity-modulated proton therapy (IMPT) presents significant challenges due to large target volumes and anatomical changes. Geometric deviations al...

Effect of Variation in the Ξ±/Ξ² of Cervical Cancer on Clinical Outcomes of Radiation Therapy

Authors: Dennis A. Cheek, Wei Luo, Cameron Thayer-Freeman, Brien Timothy Washington

Affiliation: UT Southwestern Medical Center, University of Kentucky, Department of Radiation Medicine, University of Kentucky

Abstract Preview: Purpose: To investigate the effect of variation in the Ξ±/Ξ² of cervical cancer on clinical outcome for cervix cancer patients treated with radiation therapy.
Methods: A distribution of experimentall...

Estimation of Brain Tumor’s Intra-Fraction Movement during Radiosurgery Using Fiducial Markers on the Skin Surface – a Simulation Study

Authors: Damien C. Mathew, Brandon Hai Nguyen, Satwik Pani, Yoichi Watanabe

Affiliation: Minnespolis Radiation Oncology, Department of Radiation Oncology, University of Minnesota Medical School, Washington University

Abstract Preview: Purpose: To formulate a computational algorithm to quantify the tumor movement from the motion data of landmarks on the brain surface. To estimate the magnitude of tumor movement when the head makes a...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Imaging of Mn Washout in the Individual Welder Brain after Wearing Powered Air-Purifying Respirators (PAPRs)

Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park

Affiliation: Purdue University

Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...

Implementing a Fully Automated, Web-Based Dashboard for Tracking Patient Progression through the Radiotherapy Workflow

Authors: James M. Lamb, Jack Neylon, Dylan P. O'Connell

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: Communication is imperative to safe, accurate, and timely radiotherapy. The past decade has seen a significant shift toward higher doses and shorter fractionations, which has in turn led to i...

Improved SNR and Estimation Accuracy for Deuterium-MRI Acquired with Chemical Shift Imaging at 7 Tesla

Authors: Muhammed AR Anjum, Andrew J. Fagan

Affiliation: Mayo Clinic

Abstract Preview: Purpose:
This study describes a novel post-processing method to boost image SNR for deuterium-MRI acquired using chemical shift imaging (CSI) at 7T. Deuterium MRI via exogenous administration of a ...

Improved Setup Accuracy for Dibh Whole Breast Radiotherapy with Surface-Guided Radiation Therapy

Authors: CheukKai Becket Hui, Goldie M. Klein, Yildirim D. Mutaf, Amir Pourmoghaddas

Affiliation: UC Health, Kaiser Permanente

Abstract Preview: Purpose:
In this study, we investigated the effect of SGRT (Align-RT) implementation on patient setup accuracy for DIBH breast radiotherapy treatments.
Methods:
We extracted vertical post-ima...

Intelligent Black Box Recording for Radiation Therapy: Feasibility Study of Vision-Language Models for Treatment Monitoring.

Authors: Wookjin Choi, James M. Lamb, David Romanofski, David H. Thomas, Yevgeniy Vinogradskiy

Affiliation: Drexel, Department of Radiation Oncology, University of California, Los Angeles, Thomas Jefferson University

Abstract Preview: Purpose: To develop an intelligent Black Box Recorder for radiation therapy (RT) that monitors patient treatments using a vision language model.
Methods: The system captures synchronized screen rec...

Margins to Account for Cardiac and Respiratory Motion in Cardiac Radioablation

Authors: Alanah M. Bergman, Marc W Deyell, Tania Karan, Jakob Marshall, Justin Poon, Devin Schellenberg, Steven Thomas, Richard Thompson

Affiliation: University of British Columbia, University of Alberta, BC Cancer

Abstract Preview: Purpose: A conservative approach to account for random errors due to intra-fraction cardiac and respiratory motion during cardiac radioablation (CR) is to define a margin equal to the amplitude of car...

Minimizing Positioning Errors in Intracranial SRS: The Role of Verification Imaging after 6-Dof Corrections

Authors: Anthony J. Doemer, Yimei Huang, Benjamin Movsas, Ellen Park, Mira Shah, Salim Siddiqui, Karen C. Snyder, Kundan S Thind, Bo Zhao

Affiliation: Henry Ford Health

Abstract Preview: Purpose: The 6 degrees-of-freedom (6-DoF) robotic couch is considered essential for linac-based stereotactic radiosurgery (SRS), particularly for irregularly shaped targets adjacent to critical organs...

Multi-Criteria Optimization in Medical Physics Resource Allocation: Design of an Efficient and Equitable Scheduling System

Authors: Dalton Griner, Kathryn L. Kolsky, Joseph John Lucido, Andrew J. Veres

Affiliation: Mayo Clinic

Abstract Preview: Purpose: This project aimed to automate a complex and time-consuming employee scheduling process. By replacing the traditional manual method with a multi-criteria optimization-based system (MCO), the ...

Performance Analysis of Various Deep Learning Networks for Classification of True and False Positive 18F-PSMA Findings

Authors: Vasiliki Chatzipavlidou, Ilias Gatos, George C. Kagadis, Theodoros Kalathas, Paraskevi Katsakiori, Anna Makridou, Dimitris N. Mihailidis, Nikos Papathanasiou, Ioanna Stamouli, Stavros Tsantis

Affiliation: Theageneio Hospital, University of Pennsylvania, University of Patras

Abstract Preview: Purpose: To compare the performance of multiple deep learning (DL) networks, including DenseNet201, InceptionV3, MobileNetV3, EfficientNetB2, NASNetMobile, VGG19, ResNet50, and Xception, in classifyin...

Portable Label-Free Raman Spectroscopy for Complementary Evaluation of Radiation Induced Tissue Damage

Authors: Marwan Belal AbuHaija, Anis Ahmad, Chase Prescott Anderson, Nesrin Dogan, John C. Ford, Alan Pollack, Junwei Shi, Jorge D Vega, Gabriel Enrique de Hostos

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Raman Spectroscopy (RS) is a non-invasive, label free imaging modality that gathers intrinsic molecular vibrational information. Portable RS systems expand affordability and convenience, supp...

Proactive Quality Assurance for Adaptive Radiotherapy: Real-Time Mlc Verification with Myqa SRS

Authors: James L. Giltz, Michael J. Merrick

Affiliation: Alyzen Medical Physics, University of Kentucky

Abstract Preview: Purpose: To evaluate the capability of MyQA SRS in performing high-resolution machine QA to verify multileaf collimator (MLC) behavior and integrity for adaptive radiotherapy (ART). This study demonst...

Prostate SBRT Motion Study and PTV Margin Evaluation with Exactrac Fiducial Tracking

Authors: Ahmad K. Al-Basheer, Andrew Clarke Grice, Kelly E. Hosier, Mark Logsdon, Evan A. Silverstein, Chris Tunnicliff, Chuan Wu

Affiliation: Sutter Medical Foundation, Sutter Health

Abstract Preview: Purpose: For Prostate SBRT Boost treatments, determine whether a uniform 2mm CTV to PTV margin is sufficient to give 95% dose coverage to the CTV in 90% of patients via a modified Van Herk Margin Form...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...

Towards AI-Driven Adaptive Radiotherapy: Developing a Framework for Utilizing Large-Vision Models in Head-and-Neck Cancer Treatment.

Authors: Anthony J. Doemer, Bing Luo, Benjamin Movsas, Humza Nusrat, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia

Affiliation: Department of Physics, Toronto Metropolitan University, Henry Ford Health

Abstract Preview: Purpose: Large-vision models (LVMs) are rapidly emerging, yet their application in radiation oncology remains largely unexplored. This study investigates the potential of LVMs for offline adaptive rad...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...

Use of Radiopaque Rectal Spacer for IGRT – a Preliminary Analysis of Alignment Accuracy and Interobserver Variability

Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui

Affiliation: Penn State Health Milton S. Hershey Medical Center

Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...