Authors: Bryan Bednarz, Malick Bio Idrissou, Campbell Haasch, Reinier Hernandez
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of WisconsinâMadison, University of Wisconsin - Madison
Abstract Preview: Purpose: Quantitative optical imaging is a powerful tool in murine models for assessing tumor growth and metastatic spread using bioluminescence imaging (BLI) and for detecting radiopharmaceutical upt...
Authors: Weiguo Lu, Hua-Chieh Shao, Guoping Xu, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Neural network-based lesion segmentation remains a significant challenge due to the low contrast between lesions and surrounding tissues (high ambiguity) and the variability of lesion shap...
Authors: Mateb Ali Alghamwa, Haya Aljuaid, Siyong Kim, Tianjun Ma, William Song
Affiliation: Virginia Commonwealth University
Abstract Preview: Purpose: The integration of Plastic Scintillation Detectors (PSDs) into 0.35T MR-Linac systems represents a significant advancement in radiotherapy, offering substantial benefits due to their tissue-e...
Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé
Affiliation: Montefiore Medical Center
Abstract Preview: Purpose: To characterize the âMyOSL Chipâ OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...
Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza
Affiliation: Vanderbilt University Medical Center
Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...
Authors: Shengwen Deng, Sven L. Gallo, Robert S. Jones, David W. Jordan, Arashdeep Kaur, Aishwarya M. Kulkarni, Quibai Li, William R.M. Pedersen
Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University; Department of Radiology, Louis Stokes Cleveland VA Medical Center
Abstract Preview: Purpose:
Y-90 (Yttrium) SIRT radioembolization takes advantage of delivering localized radiation to the liver. Pre-treatment dosimetry is highly dependent on accurate MAA mapping, which may have an...
Authors: NadÚge Anizan, David Broggio, Eric Chojnacki, Estelle Davesne, Didier Franck, Stéphanie Lamart, Alexandre Pignard
Affiliation: Institut Bergonié, Service de Physique Médicale, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSN-RES/SEMIA/LSMA
Abstract Preview: Purpose: To develop an innovative method enabling a comprehensive uncertainty budget associated to personalized absorbed doses for 177Lu-PSMA therapy and providing probability distributions of all dos...
Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx
Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique
Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...
Authors: Denis Bergeron, Larry A. DeWerd, Sean Jollota, Peyton Alexandra Lalain, Likhitha Polepalli
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, National Institute of Standards and Technology
Abstract Preview: Purpose: 90Y is a challenging radionuclide to measure because it is a pure beta-emitter and is typically quantified using a radionuclide calibrator. These devices, such as the Capintec model used in t...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers SÞrensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich), Ludwig-Maximilians UniversitĂ€t, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers SĂžrensen, Matthias WĂŒrl
Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam
Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.
Methods:...
Authors: Varsha Jain, Jun Kang, Paul Sulivan, Kate E. Verma, Yevgeniy Vinogradskiy
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose:
Patients undergoing treatment for head and neck(H&N) cancers experience significant body contour changes throughout treatment. Body contour changes are due to tumor shrinkage, weight loss,...
Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma
Affiliation: University of California San Francisco, University of California, San Francisco, University of California
Abstract Preview: Purpose: Introduced in 2018, the Varian Halcyon platform has increased in popularity due to its reduced cost, user-friendly design, and operational efficiency. As this platform ages, major repairs, in...
Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang
Affiliation: Radiation Oncology, Keck School of Medicine of USC
Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...
Authors: Jorge De La Cerda, Andrew Joseph Fanning, Tianzhe Li, Xiaofei Liang, Grace Murley, Mark Pagel, William Schuler, Renee Tran, Shuo Wang, Su-Min Zhou
Affiliation: University of Wisconsin Madison, University of Nebraska Medical Center, University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Electron paramagnetic resonance imaging (EPRI) can be used to image partial pressure of oxygen (pO2) in tumor models. The goal of this study is to develop an Oxygen Enhanced EPRI protocol to ...
Authors: Ben Piacitelli, Celeste Winters
Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University
Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...
Authors: NadÚge Anizan, Jean-Noël Badel, Thomas Baudier, David Broggio, Désirée Deandreis, Ludovic Ferrer, Didier Franck, Camilo Garcia, Jean Gasteuil, Anne-Laure Giraudet, Olivier Humbert, Laetitia Imbert, Malick Koulibaly, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard, Caroline Rousseau, Guido Rovera, David Sarrut, Paul Schwartz, Nicolas Varmenot
Affiliation: Institut de CancĂ©rologie de lâOuest, Service de MĂ©decine NuclĂ©aire, Gustave Roussy, Service de Physique MĂ©dicale, Institut BergoniĂ©, Service de Physique MĂ©dicale, CHRU de Nancy Brabois, Service de MĂ©decine NuclĂ©aire, Centre de lutte contre le cancer LĂ©on BĂ©rard, UniversitĂ© de Lyon, Centre Antoine Lacassagne, Service de MĂ©decine NuclĂ©aire, UniversitĂ© Nice CĂŽte dâAzur, Centre Antoine Lacassagne, Service de MĂ©decine NuclĂ©aire, Gustave Roussy, Service de MĂ©decine NuclĂ©aire, Institut de CancĂ©rologie de lâOuest, Service de Physique MĂ©dicale, Service de MĂ©decine NuclĂ©aire, AutoritĂ© de SĂ»retĂ© NuclĂ©aire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, AutoritĂ© de SĂ»retĂ© NuclĂ©aire et de Radioprotection (ASNR), PSE-SANTE/SDOS, CREATIS CNRS UMR 5220; INSERM U 1044; UniversitĂ© de Lyon; INSAâLyon, CREATIS CNRS UMR 5220; INSERM U 1044; UniversitĂ© de Lyon; INSAâLyon; Centre de lutte contre le cancer LĂ©on BĂ©rard, Institut BergoniĂ©, Service de MĂ©decine NuclĂ©aire
Abstract Preview: Purpose: The main objective of the Lu-PSMA-Dose study, sponsored by ASNR, is to estimate retrospectively the individual absorbed dose delivered to patients treated with 177Lu-PSMA for metastatic castr...
Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek
Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster
Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...
Authors: Giorgi Archuadze, William P. Donahue, David Kanchaveli, Shih-Chi Lin, Sebastian Meyer, Grace Tang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Breathing traces captured at simulations are often used for deep-inspiration breath-hold (DIBH) treatments. However, systematic drift can occur in the traces that is unrelated to the patients...
Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania
Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...
Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija
Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging
Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...
Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray
Affiliation: University of California San Diego
Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...