4DCT Vs 5DCT: How to Generate an Accurate Target Volume

Authors: Ryan Andosca, Rojine T. Ariani, Peter Boyle, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, Los Angeles, UCLA Radiation Oncology

Abstract Preview: Purpose: To demonstrate that 5DCT can provide an accurate internal tumor volume (ITV) while 4DCT cannot.
Methods: The 5DCT imaging protocol uses a motion model and 25 deformably registered free-bre...

A New Algorithm for Charged Particle Therapy Beam Energy Measurement By Time-of-Flight

Authors: Sung Woon Choi, Dong Wook Kim, Jin Sung Kim, Na Hye Kwon, Paulo Jorge Ribeiro Da Fonte

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Coimbra Institute of Engineering, Polytechnic University of Coimbra

Abstract Preview: Purpose: In hadrontherapy, such as proton and carbon ion therapy, it is desirable, for quality assurance reasons, to have an online beam energy measurement independent from the machine parameters. Sin...

Assessing Mlc Errors and Their Dosimetric Impact Delivered on Elekta Linear Accelerator from Two TPS Systems

Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Dosimetric Comparison of 6X and 10X Flattening Filter-Free Photon Beams on a Truebeam Linac Using the Eclipse TPS

Authors: Carlos E. Cardenas, Udbhav S. Ram, Marcin Wierzbicki

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham, Juravinski Cancer Centre

Abstract Preview: Purpose:
This study aims to systematically evaluate the dosimetric properties and delivery efficiency of 6X-FFF and 10X-FFF beams for lung SBRT on the Varian TrueBeam STx using the Eclipse TPS 16.1...

Dual-Modality Protoacoustic and Ultrasound Imaging for Real-Time Monitoring of Proton Therapy In Vivo

Authors: Kristina Bjegovic, Yong Chen, Lucia Rodriguez Gonzalez, Marti Roper, Liangzhong Xiang

Affiliation: University of California, Irvine, University of California Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is an increasingly popular cancer treatment due to its precision, enabled by the Bragg Peak (BP), which minimizes side effects. This profile necessitates in-patient localizatio...

Early Evaluation Study for Stereotactic Adaptive Radiotherapy for Pancreatic Cancer with Ethos 2.0 System

Authors: Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Rojano Kashani, Kyle O'Carroll, Gisele Castro Pereira, Christian Erik Petersen, Alex T. Price, Meiying Xing, Reine abou Zeidane

Affiliation: university hospital, University Hospitals Seidman Cancer Center

Abstract Preview: Purpose:
Experimental data have shown the inconsistent monitor unit and target coverage in Ethos 1.1. This can lead to inaccurate dose delivery, compromising patient safety and treatment outcomes. ...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

Improving Stroke Treatment Using Magnetic Nanoparticle Sensors to Monitor Mechanical Thrombectomy

Authors: Clifford Eskey, Scott Gordon-Wylie, Scott Gordon-Wylie, Dhrubo Jyoti, Daniel Reeves, John B. Weaver

Affiliation: Flow Aluminum, Dartmouth College, Fred Hutch Cancer Center, University of Washington, Dartmouth-Health

Abstract Preview: Purpose: Mechanical thrombectomy (MT) is the preferred treatment for ischemic stroke from large vessel occlusion. The thrombus or clot is extracted from the vessel via a catheter using a stent retriev...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accurayโ€™s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accurayโ€™s Radixact machine, and dose calculation algorithm, do...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Prostate Dosimetric Comparison between Cyberknife and Radixact Modalities Using Precision and Raystation Planning Systems

Authors: Mireille Conrad, Cรฉdric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: The Accuray Synchrony real-time motion fiducial tracking solution allows for prostate stereotactic treatment on both Cyberknife and Radixact machines. In our radiotherapy department, two solu...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...