Search Submissions πŸ”Ž

Results for "printed end": 11 found

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

Commissioning and Evaluation of Deviceless 4DCT

Authors: Christopher A. Aguilera, Hunter Tillery, Cheyann Windsor

Affiliation: Oregon Health & Science University, Northwest Medical Physics Center

Abstract Preview: Purpose: To demonstrate a method of acquiring 4DCT commissioning datasets for deviceless 4DCT which relies on an image-based algorithm instead of an external breathing signal for 4D image binning. The...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Design, Optimization, and Preclinical Validation of a Novel Applicator Integrating Real-Time Dose Monitoring for Ultra-High Dose Rate (FLASH) Electron Radiotherapy

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...

Development and Validation of Patient-Specific 3D-Printed Electron Applicators for Precision Radiotherapy

Authors: Md. Jobairul Islam

Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre

Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...

End-to-End Pre-Planning Needle Trajectory and Dwell Time Optimization for 3D Printable Cervical and Vaginal Templates

Authors: Deidre Batchelar, Michael Kudla, Stephanie Merkl, Tony Teke

Affiliation: BC Cancer - Kelowna

Abstract Preview: Purpose: Preplanning 3D-printed templates for cervical and vaginal brachytherapy is an iterative process, often taking hours to for an individual patient.
This study demonstrates an end-to-end auto...

HDR End-to-End Testing of Horizontal Leipzig Skin Applicators with Ir-192 Calibrated Oslds

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell

Affiliation: Mount Sinai Beth Israel

Abstract Preview: Purpose: Commissioning of Flexitron HDR horizontal Leipzig applicators typically includes indirect or direct output verification, using a well chamber specific Revised Correspondence Factor (CFrev) or...

Improvement of Spine Phantom for MR Imaging of the Spine

Authors: Richard Dortch, Thammathida Ketsiri, Zhiqiang Li, Shiv P. Srivastava

Affiliation: Barrow Neurological Institute, Dignity Health Cancer Institute, St. Joseph's Hospital & Medical Center

Abstract Preview: Purpose: Imaging the spinal cord post-surgery is challenging due to metal surgical implants, which induce signal loss and geometric distortions. Together, this hinders the visualization of the spinal ...

Ir-192 Percentage Depth Ionization of PLA and Ballistic Gelatin Compared to Water

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell

Affiliation: Northwell, Mount Sinai Beth Israel

Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...

Ocular HDR Brachytherapy End-to-End Dose Verification with Iridum-192 Calibrated Oslds

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell

Affiliation: Mount Sinai Beth Israel

Abstract Preview: Purpose: Ocular HDR brachytherapy is used as an alternative treatment for eye cancer, especially with extrascleral extension in the orbit. This complex procedure inserts catheters into the orbit affix...

Optically Guided Speculum for Needle or Other Probe-Based Interventions in Small Animals

Authors: Michael B. Altman, Marlene Campos Guerrero, Stephanie Markovina, Aaron Silvus

Affiliation: Washington University School of Medicine

Abstract Preview: Purpose: Currently, fluid injections or needle biopsies in small animals are conducted with limited optical guidance introducing an inherent risk of infecting or injuring the animal and limits precisi...