Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White
Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ
Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...
Authors: Ziheng Deng, Yao Hao, Runping Hou, Deshan Yang, Jun Zhao, Yufu Zhou
Affiliation: Department of Radiation Oncology, Duke University, School of Biomedical Engineering, Shanghai Jiao Tong University, Washington University School of Medicine, Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: 4D CBCT has been developed to provide dynamic images for image-guided radiation therapy. However, as projection data are sorted into sparse and clustered phase-specific bins, 4D CBCT images a...
Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal
Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre
Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...
Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal
Affiliation: University Hospital Southampton
Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...
Authors: Lavsen Dahal, Francesco Ria, Ehsan Samei, Justin B. Solomon, Liesbeth Vancoillie, Yakun Zhang
Affiliation: Duke University, Carilion Clinic, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Clinical diagnostic task-based optimization of CT procedures require precise and organ-specific assessments. This study investigates inter-organ noise variability to highlight the limitations...
Authors: Sijuan Huang, Zi LIU, Jing MA, Xin Yang
Affiliation: Sun Yat-sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, Guangdong, 510060, China
Abstract Preview: Purpose: To reduce the pressure of manual review of abnormal situations in manually/automatically delineated regions of interest (ROI), improve its accuracy and basis.
Methods: 220 radiotherapy pat...
Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann
Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania
Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...
Authors: Jiajin Fan, Ulrich Langner, Qiongge Li, Jian Liu, Wei Nie, Edwin Quashie
Affiliation: Brown University Health, Hofstra University Medical Physics Program, Inova Hospital, Inova Schar Cancer Institute, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose:
Chart checking in radiotherapy ensures treatment plans meet clinical and safety standards. For patients in clinical trials, protocol-specific requirements add complexity, making manual rev...
Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor
Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.
Methods: Electron FLASH beams of 6 MeV and 9 Me...
Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal
Affiliation: Sunnybrook Health Sciences Centre
Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...
Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...
Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier
Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson
Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...
Authors: Ryan Andosca, Peter Boyle, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Dylan P. O'Connell, Ricky R Savjani
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, UCLA, University of California, Los Angeles, UCLA Radiation Oncology
Abstract Preview: Purpose: To demonstrate the performance of the model-based CT scanning protocol, 5DCT, as an alternative to 4DCT.
Methods: 5DCT imaging results for 242 patients were analyzed. Implementation of the...
Authors: Hyo-Min Cho, Cheolpyo Hong, Changwoo Lee, Sunyoung Lee
Affiliation: Daegu Catholic University, Korea Research Institute of Standards and Science (KRISS), Korea Research Institute of Standards and Science
Abstract Preview: Purpose: With the increasing prevalence of metabolic syndrome, the importance of diagnosing obesity and fatty liver diseases has grown significantly. As a result, there is a rising demand for non-inva...
Authors: Md. Jobairul Islam
Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre
Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...
Authors: Henry Szu-Meng Chen, Mu-Lan Jen, Vinodh A. Kumar, Ho-Ling Anthony Liu, Jian Ming Teo
Affiliation: School of Medicine, University of Colorado Denver, Department of Neuroradiology, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Resting-state (rs-) fMRI detects functional networks by measuring synchronization of low-frequency oscillations in blood-oxygenation-level-dependent (BOLD) signals between brain regions. Stan...
Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé
Affiliation: Montefiore Medical Center
Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...
Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal
Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center
Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...
Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...
Authors: Shatha Al Afifi, Hana Baroudi, Leonard Che Fru, Laurence Edward Court, Suzanne B. Evans, Kent A. Gifford, Adam D. Melancon, Melissa P. Mitchell, Issa Mohamad, Patricia Murina, Manickam Muruganandham, Tucker J. Netherton, Callistus M. Nguyen, Joshua S. Niedzielski, Deborah L. Schofield, Simona Shaitelman, Willie Shaw, Sanjay S. Shete, Adam Shulman, Brendon Smith, Sheeba Thengumpallil, Carlos Daniel Venencia, Conny Vrieling
Affiliation: University of Cape Town, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, University of the Free State, UT MD Anderson Cancer Center, King Hussein Cancer Center, Instituto Zunino - Fundacion Marie Curie, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Dra., Hirslanden Clinique des Grangettes, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Therapeutic Radiology, Yale University School of Medicine, Yale University, The University of Texas, MD Anderson, Houston TX
Abstract Preview: Purpose:
Automated contouring and planning tools are usually trained on single-institution datasets, seldom tested across diverse patient populations. This introduces a risk of population bias, res...
Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang
Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital
Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...
Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng
Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program
Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂsica Gleb Wataghin
Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Wagner Henrique Marques, Raphael Morata, Victor H.F Oliveira
Affiliation: University of SĂŁo Paulo (USP), Institute of Physics
Abstract Preview: Purpose: This study investigates the feasibility of 3D printing materials in creating anthropomorphic kidney phantoms that accurately simulate the radiological properties of human tissues, for applica...
Authors: Claire Keun Sun Park, Atchar Sudhyadhom, Veena Venkatachalam, Noah Warner
Affiliation: HarvardâMIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: Modern radiotherapy achieves sub-millimeter spatial accuracy but fails to account for patient- and spatially-specific variations in biological response. Free radical generation (FRG), particu...
Authors: Cecelia Brewington, Connor Edwards Miles All Leska-Kent, Kyrillos Grace, Katherine Hyde, Sabee Molloi, Shiva Mostafavi, Liqiang Ren, Alireza Shojazadeh, Justin Truong
Affiliation: Department of Radiology, UT Southwestern Medical Center, University of California, Irvine, University of Texas Southwestern
Abstract Preview: Purpose: To retrospectively assess image quality in coronary CT angiography (CCTA) using a patient-specific post-trigger delay (PTD) protocol, developed using half of the injection time plus a dispers...
Authors: John M. Boone, Andrew M. Hernandez, Paul E. Kinahan, Michael F. McNitt-Gray, Jeffrey H. Siewerdsen, Ali Uneri
Affiliation: University of California, Johns Hopkins Univ, UT MD Anderson Cancer Center, David Geffen School of Medicine at UCLA, University of Washington, UC Davis Health
Abstract Preview: Purpose: Measuring image quality (IQ) in large clinical databases, such as the Medical Imaging and Data Resource Center (MIDRC), is challenging due to the inherent complexity of image content and the ...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...
Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam
Affiliation: University of Michigan
Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...
Authors: Harald Keller, Iymad Mansour, Jeff D. Winter
Affiliation: Princess Margaret Cancer Centre
Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...
Authors: William N. Duggar, Amirhossein Eskorouchi, Haifeng Wang
Affiliation: Mississippi State University, University of Mississippi Medical Center
Abstract Preview: Purpose:
Extracapsular extension (ECE) in lymph nodes represents a critical prognostic factor in head and neck squamous cell carcinoma (HNSCC), bearing important implications for staging, treatment...
Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...
Authors: NadÚge Anizan, Jean-Noël Badel, Thomas Baudier, David Broggio, Désirée Deandreis, Ludovic Ferrer, Didier Franck, Camilo Garcia, Jean Gasteuil, Anne-Laure Giraudet, Olivier Humbert, Laetitia Imbert, Malick Koulibaly, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard, Caroline Rousseau, Guido Rovera, David Sarrut, Paul Schwartz, Nicolas Varmenot
Affiliation: Institut de CancĂ©rologie de lâOuest, Service de MĂ©decine NuclĂ©aire, Gustave Roussy, Service de Physique MĂ©dicale, Institut BergoniĂ©, Service de Physique MĂ©dicale, CHRU de Nancy Brabois, Service de MĂ©decine NuclĂ©aire, Centre de lutte contre le cancer LĂ©on BĂ©rard, UniversitĂ© de Lyon, Centre Antoine Lacassagne, Service de MĂ©decine NuclĂ©aire, UniversitĂ© Nice CĂŽte dâAzur, Centre Antoine Lacassagne, Service de MĂ©decine NuclĂ©aire, Gustave Roussy, Service de MĂ©decine NuclĂ©aire, Institut de CancĂ©rologie de lâOuest, Service de Physique MĂ©dicale, Service de MĂ©decine NuclĂ©aire, AutoritĂ© de SĂ»retĂ© NuclĂ©aire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, AutoritĂ© de SĂ»retĂ© NuclĂ©aire et de Radioprotection (ASNR), PSE-SANTE/SDOS, CREATIS CNRS UMR 5220; INSERM U 1044; UniversitĂ© de Lyon; INSAâLyon, CREATIS CNRS UMR 5220; INSERM U 1044; UniversitĂ© de Lyon; INSAâLyon; Centre de lutte contre le cancer LĂ©on BĂ©rard, Institut BergoniĂ©, Service de MĂ©decine NuclĂ©aire
Abstract Preview: Purpose: The main objective of the Lu-PSMA-Dose study, sponsored by ASNR, is to estimate retrospectively the individual absorbed dose delivered to patients treated with 177Lu-PSMA for metastatic castr...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂsica Gleb Wataghin
Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...
Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto
Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...
Authors: James Chun Lam Chow, Kay Li
Affiliation: University of Toronto, Princess Margaret Cancer Centre
Abstract Preview: Purpose: This study explores the caution needed when using Generative AI for assessing radiotherapy ethics, highlighting Geoffrey Hintonâs warnings about the risks of relying solely on AI for ethical ...
Authors: Siju C. George, Alonso N. Gutierrez, Vivek Mishra, Ranjini P. Tolakanahalli
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute
Abstract Preview: Purpose: This presentation focuses on optimizing dosimetry in RPT clinics by tackling initial setup challenges and ensuring the accuracy of SPECT/CT imaging for dosimetry. It will address the qualific...
Authors: Hulya Ozdemir Buss, Jeffrey Geiger, Kim Howard, Julius G. Ojwang, Neelu Soni
Affiliation: Mercy Hospital Springfield
Abstract Preview: Purpose: The Radixact Synchrony system integrates real-time motion tracking and compensates to improve treatment accuracy for moving targets. This study presents a streamlined and efficient quality as...
Authors: Zhihua Qi
Affiliation: Henry Ford Health
Abstract Preview: Purpose: State of the art cardiac CT has built-in automated, patient specific optimization, taking into account a number of factors including patient size, heart rate and others. It is crucial to deve...
Authors: Wesley E. Bolch, Emily L. Marshall, Dhanashree Rajderkar, Wyatt Smither
Affiliation: University of Florida
Abstract Preview: Purpose: To determine the accuracy of TotalSegmentator, an AI-based automatic segmentation toolkit, on pediatric CT scans as the original software was trained on adult image datasets with a mean patie...
Authors: Michael Bowers, Patrik Brodin, Madhur Garg, Rafi Kabarriti, William P. Martin, Todd R. McNutt, Julie Shade, Wolfgang A. Tomé, Christian Velten
Affiliation: Johns Hopkins University, Oncospace, Inc., Montefiore Medical Center
Abstract Preview: Purpose: Development of an automated planning tool utilizing AI generated patient-specific dose-volume histogram predictions for rapid H&N plan generation.
Methods: Planning best-practices were dev...
Authors: Joke Binst, Hilde TC Bosmans, Niki Fitousi, Bram Miseur, Dimitar Petrov, Kwinten Torfs, Janne Vignero
Affiliation: Qaelum NV, Department of radiology, UZLeuven, Department of imaging and pathology, KULeuven
Abstract Preview: Purpose: Routine quality monitoring in CT abdomen is crucial for ensuring optimal image quality and patient safety, but the simultaneous evaluation of all aspects of importance is challenging. The pur...
Authors: Gong Vincent Hao, Daisuke Kawahara, Jokichi Kawazoe, Yuji Murakami, Ikuno Nishibuchi, Peiying Colleen Ruan, Daguang Xu, Dong Yang
Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University, NVIDIA
Abstract Preview: Purpose:
Accurate tumor segmentation in head and neck cancer is critical for effective treatment planning, but variability in practices across medical facilities poses challenges for standardizatio...
Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq
Affiliation: Khalifa University
Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...
Authors: Nuraddeen Nasiru Garba, Kalpana M Kanal, Abdullahi Mohammed, Rabiu Nasiru, Muhammad SHAFIU Shehu, Daniel Vergara, Joseph Everett Wishart
Affiliation: AHMADU BELLO UNIVERSITY, ZARIA, University of Washington
Abstract Preview: Purpose: To establish local Diagnostic Reference Levels (DRLs) for head and neck computed tomography (CT) exams in Abuja, Nigeria, and to investigate the performance of brain metastasis (BM) and brain...
Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...
Authors: Zijia Guo, Viktor Haase, Michael F. McNitt-Gray, Frederic Noo
Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA
Abstract Preview: Purpose: The attenuation values in CT hold strong potential for disease diagnosis. However, they lack reliability, which has limited their use to clinical trials where variability can be controlled. S...
Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray
Affiliation: University of California San Diego
Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...
Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant
Affiliation: St. Jude Children's Research Hospital
Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...