Authors: Yu Chang, Mei Chen
Affiliation: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
Abstract Preview: Purpose: Spot weights optimization, as a critical step in the proton therapy, is often time-consuming and labor-intensive. Deep learning, with its powerful learning and computational efficiency, can e...
Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng
Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...
Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal
Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...
Authors: Dale Black, David Clymer, Huanjun Ding, Hamidreza Khodajou Chokami, Sabee Molloi, Christine Vy Nguyen, Tim Sananikone, Alireza Shojazadeh, Randy Wang
Affiliation: Department of Radiological Sciences, University of California, University of California, Department of Radiological Sciences, University of California, Irvine, Department of Radiological Sciences, University of California, Irvine
Abstract Preview: Purpose: We present a novel multi-material decomposition (MMD) algorithm for accurate quantification of material concentration in reconstructed dual-energy CT images. This method addresses limitations...
Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu
Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...
Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health
Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...
Authors: Liu Hong, Wen C. Hsi, Faraz Kalantari, Romy Megahed, Ganesh Narayanasamy, Maida Ranjbar, Pouya Sabouri, Zhong Su
Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose: Quantitative apparent diffusion coefficients (ADC) in diffusion-weighted MRI (dMRI) reflect water diffusivity and thus provide tissue cellular density information. Functional diffusion mappin...
Authors: Zachary M. Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: High spatial resolution in pin ridge filter (pRF)-based proton planning may be constrained by the 1mm dose grid resolution in commercial treatment planning systems. This study investigates th...
Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser
Affiliation: Christiana Care
Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...
Authors: Ergun E. Ahunbay, Abdul Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao
Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Online adaptive replanning is often necessary in Intensity Modulated Proton Therapy (IMPT) due to the sensitivity of proton dose distributions to daily anatomical changes. A rapid, automated ...
Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos
Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen
Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...
Authors: Jorge Naoki Dominguez Kondo, Qihui Lyu
Affiliation: University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Targeted alpha therapy (TAT) has emerged as a highly potent therapeutic method in oncology, but its development is limited by the lack of imaging methods to quantify its dosimetry. Convent...
Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su
Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...
Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan
Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care
Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...
Authors: Ananta Raj Chalise, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang
Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc
Abstract Preview: Purpose: Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tool to investigate the PG emission during proton therapy and optimize ...
Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger
Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...
Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela
Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University
Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...
Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...
Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang
Affiliation: Department of Radiation Oncology, Stanford University
Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...
Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich
Affiliation: Rush University
Abstract Preview: Purpose: This study evaluates the impact of ultra-high resolution (UHR) mode on the visualization of small vessels in coronary computed tomography angiography (CTA) using a photon-counting CT scanner....
Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...
Authors: Matthew Stephen Andriotty, Taoran Cui, Harold Y Hu, Ke Nie, Tan Phan, Xiao Wang, Ning J. Yue, Chengzhu Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, Basis Scottsdale
Abstract Preview: Purpose: Metallic implants are often non-isocentric, and their exact volumes/orientations/shapes are difficult to capture and contour accurately on CT images even if that information is known beforeha...
Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa
Affiliation: National Cancer Centre Singapore
Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...
Authors: Hao Gao, Yuting Lin, Jufri Setianegara, Aoxiang Wang, Peng Xiao, Qingguo Xie, Yanan Zhu
Affiliation: Department of Biomedical Engineering, Huazhong University of Science and Technology, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Intensity-modulated proton therapy (IMPT) achieves uniform tumor dose distribution while sparing organs-at-risk (OAR) by optimizing spot weights across energy layers. Accelerating IMPT delive...
Authors: Yaowen Cao, Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Xiaogang Yuan
Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China
Abstract Preview: Purpose: Magnetic resonance imaging (MRI)-guided proton therapy is an innovative technology that combines superior soft tissue imaging capabilities of MRI with the high dose conformity of proton thera...
Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang
Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China
Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...
Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin
Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: Decreased lymphocytes increase the risk of infections and other problems. Radiation exposure can cause the development of severe lymphopenia. In this study, we used a dynamic blood flow model...
Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav
Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute
Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...
Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West
Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma
Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...
Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng
Affiliation: New York Proton Center, Scarsdale High School
Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...
Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey
Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong
Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...
Authors: Alexei V. Chvetsov, Pavitra Ramesh, Alexei V. Trofimov
Affiliation: Massachusetts General Hospital, University of Washington
Abstract Preview: Purpose: To investigate the effect of dose and depth dependence of relative biological effectiveness (RBE) on hypofractionated proton therapy for ocular melanoma using equivalent uniform RBE-weighted ...
Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu
Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou
Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...
Authors: Zakaria Aboulbanine, Greeshma A. Agasthya, Paul Inman, Anuj J. Kapadia, Anthony Hong Cheol Lim, Jayasai Ram Rajagopal, Chris C. Wang
Affiliation: Oak Ridge National Laboratory, Georgia Institute of Technology
Abstract Preview: Purpose: Radiobiological simulation via TOPAS-nBio requires significant computational resources and time to provide meaningful results. This study aims to decrease simulation time and computational re...
Authors: John Ford, Yu Fujiwara, Isao Murata, Zavier Ndum Ndum
Affiliation: Osaka University, Texas A&M University
Abstract Preview: Purpose: This study investigates how particle energy affects radiation quality and biological effectiveness with the inclusion of medical implants. Our research group used microdosimetric analysis to ...
Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez
Affiliation: University of Miami
Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...
Authors: Ergun E. Ahunbay, Abdul Kareem Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao
Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Secondary dose calculations (SDC) facilitate patient-specific quality assurance for online adaptive intensity-modulated proton therapy (IMPT). However, there is currently a lack of commercial...
Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga
Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...
Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina
Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.
Methods: Dose calculations in water phan...
Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...
Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington
Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...
Authors: Claus Belka, Stefanie Corradini, George Dedes, Nikolaos Delopoulos, Christopher Kurz, Guillaume Landry, Ahmad Neishabouri, Domagoj Radonic, Adrian Thummerer, Niklas Wahl, Fan Xiao
Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, LMU Munich, Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO)
Abstract Preview: Purpose: In MR-guided online adaptive radiotherapy, MRI lacks tissue attenuation information necessary for accurate dose calculations. Instead of using deep learning methods to generate synthetic CT i...
Authors: Wen C. Hsi, Kayla Schneider
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...
Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana
Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East
Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...
Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...
Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...
Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka
Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...
Authors: John P. Aris, Wesley E. Bolch, Chansoo Choi, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Abdul-Vehab Dozic, Amy M. Geyer, Harald Paganetti, Shreya P. Pathak, Julia D. Withrow
Affiliation: St. Luke's Health System, Massachusetts General Hospital, University of Florida
Abstract Preview: Purpose: The goal of this study was to enhance the accuracy of renal dosimetry in radiopharmaceutical therapy (RPT) by developing a more detailed and precise kidney model. In RPT, accurate dose estima...
Authors: Sam Beddar, Brett Bocian, David B. Flint, Benjamin Abraham Insley, Patrick James Jensen, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Reza Reiazi, Gabriel O. Sawakuchi
Affiliation: University of Miami, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Empyrean Medical Systems, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: The Harrison-Anderson-Mick (HAM) applicator is an Ir-192 High-Dose-Rate (HDR) intraoperative radiotherapy device. It features a silicone body with embedded catheters that guide the Ir-192 sou...
Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi
Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais
Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...
Authors: Ana Maria Barragan Montero, Damien Dasnoy, Sylvain Deffet, Valentine Dormal, Colin Gaban, Melanie Ghislaine, Valentin Hamaide, Guillaume Janssens, John A. Lee, Eliot Peeters, Danah Pross, Luciano Rivetti, Benjamin Roberfroid, Romain Schyns, Kevin Souris, Edmond S. Sterpin, Sophie Wuyckens
Affiliation: Ion Beam Applications SA, Hospital Riviera-Chablais, UCLouvain, Multitel, Université Catholique de Louvain, IBA, Faculty of Mathematics and Physics, University of Ljubljana, Universite Catholique de Louvain
Abstract Preview: Purpose: Treatment planning systems (TPSs) are essential for simulating and optimizing radiotherapy treatments. However, clinical TPSs are expensive software commercialized by private companies and of...
Authors: Estelle Batin, Michael A. Carlson, Nilendu Gupta, Zachary X. Richards, Diana Shvydka
Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center
Abstract Preview: Purpose: With an increase in world-wide proton treatment availability, patients sometimes are transferred between proton and photon modalities. Among the main reasons for modality shifts are proton be...
Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung
Affiliation: Mayo Clinic - Rochester
Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...
Authors: Yankui Chang, Shijun Li, Xi Pei, Ripeng Wang, Xuanhe Wang, X. George Xu, Qing Zhang, Jingfang Zhao
Affiliation: University of Science and Technology of China, Shanghai proton and heavy ion center, School of Nuclear Science and Technology, University of Science and Technology of China, Anhui Wisdom Technology Co., Ltd.
Abstract Preview: Purpose:
This paper describes disruptive methods using both GPU-based MC simulation and deep-learning (DL)-based MC denoising algorithms, as well as clinical tests involving more than 560 patient p...
Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey
Affiliation: Thompson Proton Center
Abstract Preview: Purpose: Linear energy transfer (LET) and variable relative biological effectiveness (RBE) evaluation are important steps in the future of proton therapy, moving beyond RBE=1.1 for all treatment plann...
Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang
Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill
Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...
Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao
Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis
Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...
Authors: Amanda J. Deisher, Susannah V. Hickling, Shima Ito, Jon J. Kruse
Affiliation: CancerCare Manitoba, Mayo Clinic
Abstract Preview: Purpose:
To date, 11 ocular patients were treated with spot scanning gantry-based gaze-gated ocular proton program at Mayo Clinic, Rochester MN since 2023. Treatments are done in the half-arc gantr...
Authors: Curtiland Deville, Rachel B. Ger, Elaina Hales, Heng Li, Todd R. McNutt
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Lack of specialized coding knowledge limits the use of data from large SQL repositories. We aimed to develop intuitive user interfaces for a registry that allows users to visualize the relati...
Authors: Michael Dingfelder
Affiliation: East Carolina University
Abstract Preview: Purpose:
To study and accurately evaluate the influence of the Fermi Density effect on stopping powers and cross sections of charged particles in liquid water used in Monte Carlo radiation transpor...
Authors: Kevin Peter Risolo
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: To quantify the improved efficiency of checking patient treatment plan MU by utilizing RadFormation’s ClearCalc script-based program.
Methods: A total of 58 patients planned for treatment ...
Authors: Hongyu Jiang
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: This study presents a method for transforming coordinates from RayStation’s treatment planning system into the Monte Carlo (MC) coordinate system used in GEANT4 for dose calculations in spot ...
Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions
Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...
Authors: Harold Y Hu, Yanle Hu, Shuai Leng, Maryam Sadeghian, Joe Swicklik
Affiliation: Mayo Clinic Arizona, Basis Scottsdale, Mayo Clinic
Abstract Preview: Purpose: Radiotherapy CT simulation often requires two scans: a non-contrast scan for dose calculation and a contrast-enhanced scan for target delineation. Photon-counting-detector (PCD) CT allows the...