A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

A GPU Accelerated Monte Carlo Dose Engine for Small Animal Proton Radiotherapy

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A New Algorithm for Charged Particle Therapy Beam Energy Measurement By Time-of-Flight

Authors: Sung Woon Choi, Dong Wook Kim, Jin Sung Kim, Na Hye Kwon, Paulo Jorge Ribeiro Da Fonte

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Coimbra Institute of Engineering, Polytechnic University of Coimbra

Abstract Preview: Purpose: In hadrontherapy, such as proton and carbon ion therapy, it is desirable, for quality assurance reasons, to have an online beam energy measurement independent from the machine parameters. Sin...

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

Artificial Intelligence-Powered Conventional Energy Integrating Detector-Based Coronary CT Angiography: Learning High-Resolution and Multi-Energy Imaging from Photon-Counting Detector CT

Authors: Shaojie Chang, Thomas A. Foley, Hao Gong, Emily Koons, Shuai Leng, Cynthia H. McCollough, Eric E. Williamson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To enhance coronary CT angiography (cCTA) capabilities on conventional energy integrating detector CT (EID-CT) using artificial intelligence (AI). The AI framework incorporates high-resolutio...

Assessment of Plan Quality Metrics for Iroc Houston SRS Phantom Performance Evaluation

Authors: Derek Matthew Garcia, Mallory Glenn, Stephen F. Kry, Ruitao Lin, Dennis S. Mackin, Tucker J. Netherton

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas’ MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: This study aims to investigate the feasibility of implementing clinically relevant quality metrics for evaluating IROC SRS phantom plans, including conformity index (CI) and homogeneity index...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

BEST IN PHYSICS THERAPY: Fast and Convenient Proton Pencil Beam Energy QA with Multi-Layer Faraday Cup (MLFC)

Authors: Paul Boisseau, Eric S. Diffenderfer, Andrew Friberg, Wenbo Gu, Matthew Nichols, Kan Ota, Xiaokun Teng, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, Pyramid Technical Consultants, Inc., University of Pennsylvania

Abstract Preview: Purpose: Traditional quality assurance procedures for proton pencil beam energies involve water tank setups or multiple solid water phantoms and are time-consuming. This study demonstrates that an inn...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterization of Image Intensified Cherenkov Cameras for Development of Direct CMOS-Based Detection Systems

Authors: Petr Bruza, Eric R. Fossum, Alexander Geiersbach, David J. Gladstone, Karthik Raj Venkatesan

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Current Cherenkov imaging sensors rely on image intensifiers to generate sufficient signal for photon detection. While image intensifiers (IIs) exhibit good Cherenkov photon signal response, ...

Characterization of Linear Energy Transfer Spectra in Mini Beam Spatially Fractionated Proton Therapy

Authors: Serdar Charyyev, Kaan Dere, Edgar Gelover, Mohammad Khurram Khan, Liyong Lin, Mark McDonald, Cristina Oancea, Alexander Stanforth, Sibo Tian, Suk Whan (Paul) Yoon, Mingyao Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Advacam

Abstract Preview: Purpose: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) utilizes physical collimators with apertures to generate minibeams, creating alternating regions of high-d...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization of a Prototype Flashdiamond Detector for Conventional and Uhdr Beams

Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Commissioning Radcalc v7.3 with a Collapsed Cone Calculation Algorithm for 6X FFF and 10X FFF Energies

Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Comparison of Ultra-High Resolution and Standard CT Imaging Modes for Small Vessel Visualization in Coronary CTA Using Photon Counting CT

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: This study evaluates the impact of ultra-high resolution (UHR) mode on the visualization of small vessels in coronary computed tomography angiography (CTA) using a photon-counting CT scanner....

Correcting for the Cherenkov-to-Dose Conversion for Tset Patients Using Monte Carlo Simulations

Authors: Baozhu Lu, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: Cherenkov intensity can be quantitatively correlated to surface dose but need certain corrections for accurate dose measurements. This study aims to investigate the impact of incident beam an...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Deployable Twin-Calorimeter System for Absolute Dose Measurements By Clinical Physicists

Authors: Jean Dessureault, Malcolm R. McEwen, Bryan R. Muir, James Renaud

Affiliation: National Research Council

Abstract Preview: Purpose: To develop and commission a mailable calorimeter that enables clinical medical physicists to quickly and efficiently address innovative dosimetry challenges directly at the point of use.
<...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Direct Measurement of DNA Damage to Determine Dose and Biological Effectiveness

Authors: Michael Lamontagne, Ileana Pazos, Jerimy C. Polf, Joseph W. Robertson, Teniola Tobun, Ronald E. Tosh, Michael Zwolak

Affiliation: Biophysics and Biomedical Research Group, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, M3D, Inc, National Institute of Standards and Technology, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To study how damage to DNA molecules increases and changes as a function of the type and dose of radiation.

Methods: DNA molecules of a known length (number of base pairs (BP)) within ...

Directional Dependence of Detectors for Beam Profiles and Output Factors in Small Field Dosimetry

Authors: Indra J. Das, Ahtesham Ullah Khan, Andrew J. White

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: Small field dosimetry presents challenges due to lateral disequilibrium and the selection of suitable detectors. Volume averaging and density corrections hamper accurate profile measurements....

Dose Reconstruction from Prompt-Gamma Imaging Towards Real-Time Adaptive Proton Therapy

Authors: Thomas R. Bortfeld, Prof. Elisabetta De Bernardi, Tianxue Du, Beatrice Foglia, Chiara Gianoli, Takamitsu Masuda, Katia Parodi, Marco Pinto, Boon-Keng Kevin Teo, Yunhe Xie

Affiliation: Department Of Radiation Oncology, Massachusetts General Hospital (MGH), School of Medicine and Surgery, University of Milano-Bicocca, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich), Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, National Institutes for Quantum Science and Technology (QST), University of Pennsylvania, Department of Experimental Physics - Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen

Abstract Preview: Purpose: The full potential offered by protons in clinical practice is limited by range uncertainties. One possibility for monitoring is through secondary prompt gammas (PG). PG emission along the pen...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectorsℱ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

Dosimetric Validation and Algorithmic Limitations of Pencil Beam Scanning Proton Therapy for Thin Chest-Wall Treatments

Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng

Affiliation: New York Proton Center, Scarsdale High School

Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...

Dosimetry Calibration for Low-Energy Protons (2-4 MeV) Using Gafchromic Film Dosimeters

Authors: Michael Dingfelder, Homeira Faridnejad

Affiliation: East Carolina University, Department of Physics, East Carolina University

Abstract Preview: Purpose: To use Gafchromic film for measurement of the dose delivered by low-energy (2-4 MeV) protons to living cells.
Methods: Five different types of Gafchromic films were tested for dosimetry un...

Dosimetry Impact of Beam Flatness on a Clinical Synchrocyclotron Proton System

Authors: Winter Green, Yao Hao, Nels C. Knutson, Matthew C. Schmidt, Xiandong Zhao

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, WashU Medicine

Abstract Preview: Purpose: Beam profile flatness is crucial for both photon and proton radiotherapy systems. This work investigated the dosimetry impact of beam flatness on a clinical synchrocyclotron proton system.

Dual-Energy CT Derived Perfusion Blood Volume and 4D-CT Derived Ventilation Changes in Lung Cancer Patients 6-Months Post Radiation Therapy

Authors: Daniel A. Alexander, Jeffrey D. Bradley, Steven J. Feigenberg, Cole Friedes, Casey Hollawell, William Levin, Maksym Sharma, Boon-Keng Kevin Teo, Ying Xiao, Nikhil Yegya-Raman, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology and Applied Sciences, Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: To investigate lung function changes following definitive chemoradiation dose using CT-derived measurements in patients with locally advanced NSCLC at 6-months post-treatment compared to pre-...

Dynamic 2.5D Surface Dosimetry Using Deformable Scintillator Array Imaging

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous, Roman Vasyltsiv, Rongxiao Zhang

Affiliation: Dartmouth Health, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri

Abstract Preview: Purpose: On-patient dosimeters assist in clinical decision-making by measuring surface dose, but single-point measurements cannot monitor area-wide distributions and are misleading in high-gradient re...

Enhanced Surface Dose Accuracy in Proton Treatment Planning: Optimizing External Volume HU Thresholding.

Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez

Affiliation: University of Miami

Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: ClĂ­nica Iram, Clinica Alemana, Hospital ClĂ­nico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluation of Four Different Dose Calculation Algorithms for Commissioning of a New Tyoe of Scanned Proton Therapy System

Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga

Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University

Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...

Evaluation of Ion Chamber Performance and Suitability for Flash Proton Therapy Dosimetry

Authors: Seohyeon An, Yoonsun Chung, Seonghoon Jeong, Seongmoon Jung, Chae-Eon Kim, In Jung Kim, Sung Hun Kim, Se Byeong Lee, Sang-il Pak, Jong In Park

Affiliation: POHANG ACCELERATOR LABORATORY, Hanyang University, Korea Research Institute of Standards and Science (KRISS), Ilsan Paik Hospital, National Cancer Center, National Cancer Center Korea, Korea Research Institute of Standards and Science

Abstract Preview: Purpose: To evaluate the performance of three ion chambers—Advanced Markus (AMC), PinPoint, and Roos—under FLASH proton beam conditions and assess the response of the nozzle monitor chamber for their ...

Evaluation of MR Proton Density Fat Fraction (PDFF) for Bone Marrow Protection in RT

Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang

Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital

Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...

Evaluation of Nodule Volume Accuracy with Deep Learning-Based Reconstructions on Cdznte Photon-Counting and Energy-Integrating CT

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...

Evaluation of an Analytical Simulation Technique By Comparing Transmitted Spectra Against GEANT4 through a Hafnium-Loaded Heterogeneous Phantom

Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Feasibility of Commercial Independent-Dose-Calculation for Pencil-Beam-Scanning Proton Therapy

Authors: Wen C. Hsi, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...

Feasibility of a Bench-Top Pcct Model for Electronic Density Measurements: A Monte Carlo Simulation Study

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Renan Felix dos Santos, Gustavo Freire Pereira da Silva, Alessandra Tomal

Affiliation: University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: Evaluate the feasibility of a bench-top PCCT using Geant4 Monte Carlo simulations. The study applied the Geant4 framework on determining the electronic density of materials as a function of C...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

Free-Breathing Spirometer-Gated Proton Pencil Beam Scanning Delivery Maintains Tumor Coverage with Improved Organ-at-Risk Sparing: A Motion Phantom Validation

Authors: Uriel Aura, Qing Chen, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Meng Wei Ho, Sheng Huang, Minglei Kang, Stanislav Lazarev, Nancy Y Lee, Yang Lei, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Anna Zhai, Ajay Zheng

Affiliation: DYN'R Medical System, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Tianjin Medical University Cancer Institute&Hospital, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Managing tumor motion during pencil beam scanning proton therapy remains challenging. This study investigated the feasibility and dosimetric benefits of Free-Breathing Respiratory-Gated Deliv...

From Supine to Upright: A Geometric Shift in Perspective

Authors: Ben Durkee, Renata Farrell, Carri K. Glide-Hurst, Colin Harari, Alex Singleton Kuo, Chase Ruff, Jordan M. Slagowski, Yuhao Yan

Affiliation: University of Wisconsin, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Advances in upright CT and patient positioning system now enables high quality daily CT imaging and treatment delivery in the upright position, providing benefits including reduced internal m...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Impact of Translucent Sheet Bolus and Melanin Concentration on Recorded Optical Signal during Cherenkov Imaging in External Beam Radiation Therapy

Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington

Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center

Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Improving Output Stability with Angular Correction Factor on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...

Interplay of Relative Biological Effectiveness and Dose Rate in Eye Plaque Brachytherapy with Low Energy Photons

Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart

Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington

Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Lung Nodule Volume Estimation: Performance of Conventional Energy-Integrating and Cdznte-Photon-Counting CT Using Hybrid Reconstruction Method

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Neutron Dose Measurements with Multiple Dosimetry Techniques for Fetal Dose Estimation

Authors: Ahmet S. Ayan, Estelle Batin, Austin M. Faught, Peter E. Klages, Eunsin Lee, Collin Nappi, Mina Okello, Meghana Ramani, Zachary X. Richards, Parisa Sadeghi

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: Neutron doses are not modelled in proton treatment planning systems, so measurements were taken with two independent dosimeter types to quantify representative neutron fetal doses in pencil b...

Off-Axis Dependency of the Sun Nuclear MapCheck3 Diode Array

Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: The Sun Nuclear MapCheck3 device is used for patient-specific QA. While it is typically employed in perpendicular field-by-field delivery using the Isocentric Mounting Fixture, fields not ful...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Photon-Proton Treatment Compatible Couch Tops Render Modality-Dependent Support Structure Models

Authors: Estelle Batin, Michael A. Carlson, Nilendu Gupta, Zachary X. Richards, Diana Shvydka

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center

Abstract Preview: Purpose: With an increase in world-wide proton treatment availability, patients sometimes are transferred between proton and photon modalities. Among the main reasons for modality shifts are proton be...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Predicting Reactive Oxygen Species Generated through Photoactivation of Targeted Laser Therapy in-Silico

Authors: David Alcorta, Joseph Farina, Timothy Haystead, Philip Hughes, Keshav Jha, Mark Oldham, Victoria J. P. Radosova

Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: This study attempts to simulate the activation of targeted photodynamic molecules using visible laser light and characterize the direct Reactive Oxygen Species (ROS) generated by Cherenkov an...

Preliminary Evaluation of Ultrasound-Derived Fat Fraction Reliability in a Pediatric Cohort

Authors: Lizbeth Ayala-Dominguez, Aaron L Carrel, Diego Hernando, Gabrielle L Hoffmann, Amber Possell, Ivan M. Rosado-Mendez, Jiayi Tang, Andrew Wentland

Affiliation: Department of Pediatrics, University of Wisconsin-Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: Metabolic dysfunction-associated steatotic liver disease (MAFLD) is the leading cause of chronic liver disease in children. While biopsy remains the diagnostic standard, non-invasive imaging ...

Proton Measurement By Vipet Gel Dosimeter

Authors: Ai Nakaoka

Affiliation: Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: N/A...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Quantitative Accuracy in Iodine Measurements and CT Numbers Using Standard and Ultra-High Resolution Photon-Counting CT in Coronary CTA

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...

Reconstructing Radiopharmaceutical Distributions Using Coded Aperture Tomography with Photon Counting Detector

Authors: David P. Adam, Xun Jia, Youfang Lai, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Radiopharmaceutical therapy is experiencing a resurgence in interest due to its potential of treating widespread metastatic disease in a patient-specific manner. Accurately measuring and desc...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

The Z Dimension Matters: 3D Noise Power Spectrum of a Clinical Photon Counting Detector CT System

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, Humberto Monsivais, John Rong

Affiliation: Purdue University, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To investigate the noise characteristics of a clinical photon counting detector CT (PCD-CT) system along axial and through-plane (Z) dimensions using 3D NPS measurements.
Methods: This stu...

Two's Company, Three's a Crowd? a Bayesian Approach to Optimizing the Number of Measurement Readings in Radiation Therapy QA

Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...