3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

4π Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4π non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Comparison of on-Isocenter Vs Off-Isocenter Planning for Lung SBRT on the Viewray Mridian

Authors: Nebi Demez, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Treatment plans on the ViewRay MRIdian are often planned with the target placed off isocenter due to the proximity of the bore to the patient, allowing for limited shifts. This is especially ...

A Modular Approach to Reversible and Stackable Medical Imaging Translation Models: CBCT-Based Synthetic MRI with Multiple U-Nets in Series (MUNETs)

Authors: Eric Chang, Nguyen Phuong Dang, Andrew Lim, Lauren Lukas, Lijun Ma, Yutaka Natsuaki, Zhengzheng Xu, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: Harnessed the power of AI and Deep Learning (DL), Generalized Neural Network models for medical image transformation are trained to predict target images from reference images, often requirin...

A Novel Process for Electron Beam Matching on Varian True Beams

Authors: Andrew Clarke Grice, Evan A. Silverstein

Affiliation: Sutter Medical Foundation, Sutter Health

Abstract Preview: Purpose: To implement an efficient and effective process for Electron beam matching between 5 Varian True Beams (TB).
Methods: We adapted the Varian installation/acceptance process for TBs, whereby...

A Radiomics and Dosomics-Based Approach for Predicting Hematologic Toxicity in Patients with Cervical or Endometrial Cancer

Authors: Yongrui Bai, Xuming Chen, Yong Liu, Xiumei Ma

Affiliation: Department of Radiation Oncology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China, Department of Radiation Oncology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

Abstract Preview: Purpose: Hematologic toxicity (HT) is a common complication in patients with cervical or endometrial cancer. This study aims to develop a precise predictive model for acute HT in patients with cervica...

A Retrospective Assessment of Proton Radiation Response in Brain Tumor Patients Using Diffusion-Weighted MR Imaging

Authors: Liu Hong, Wen C. Hsi, Faraz Kalantari, Romy Megahed, Ganesh Narayanasamy, Maida Ranjbar, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: Quantitative apparent diffusion coefficients (ADC) in diffusion-weighted MRI (dMRI) reflect water diffusivity and thus provide tissue cellular density information. Functional diffusion mappin...

A Self-Supervised Deep Learning Approach for Automatic Identification and Metal Artifact Reduction in Cone-Beam CT for Brachytherapy

Authors: Rani Anne', Wenchao Cao, Yingxuan Chen, Wookjin Choi, Firas Mourtada, Yevgeniy Vinogradskiy

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: In-room mobile cone-beam CT (CBCT) is emerging to enhance high-dose-rate (HDR) brachytherapy workflow using on-demand imaging. However, metal artifacts from X-ray markers inside gynecological...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Advancing Cardiac Sparing with Upright Patient Geometry and Deep Learning

Authors: Shae Gans, Carri K. Glide-Hurst, Mark Pankuch, Chase Ruff, Niek Schreuder, Nicholas R. Summerfield, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center, Leo Cancer Care

Abstract Preview: Purpose: Novel upright patient positioners coupled with diagnostic-quality vertical CT at treatment isocenter introduce a significant opportunity for improved image-guided particle therapy. Treating p...

An Automated Tool for the Categorization of a Clinical Database By Anatomic Region for Big Data Applications

Authors: Yasin Abdulkadir, Justin Hink, James M. Lamb, Jack Neylon

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: Curation remains a significant barrier to the use of ‘big data’ radiotherapy planning databases of 100,000 patients or more. Anatomic site of treatment is an important stratification for almo...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Assessing an Improvement to Hyperarc SRS Planning: Comparing the Efficiency Index of Hyperarc Alone Vs Hyperarc + Surface Area Informed Optimization

Authors: Ivan L. Cordrey, Dharmin D. Desai, Ellis Lee Johnson

Affiliation: Cumberland Medical Center - Cancer Center, University of Kentucky, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: HyperArc (HA) is known to produce a high quality SRS plan. Adding Surface Area Informed Optimization (SAIO) to HA has been shown to improve plan quality metrics R50% and the Conformality Inde...

Assessing the Potential of Virtual Grid Portable Radiographic Systems for Radiation Dose Reduction: A Comparative Evaluation of Deviation Index in Abdominal Imaging

Authors: Gary Y. Ge, Azmul Siddique, Jie Zhang

Affiliation: Department of Radiology, University of Kentucky, University of Kentucky

Abstract Preview: Purpose: Virtual grid technology addresses scattered radiation without a physical grid, offering the potential to reduce patient radiation dose while maintaining image quality. However, this potential...

Automated MR Segmentation for Online Adaptive MR-Linac Therapy Using an in-House Model

Authors: David L. Barbee, David Byun, Matt Long, Jose R. Teruel Antolin, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
Online adaptive MR-Linac therapy requires contour adaptation, often adding 20 minutes to treatment time and reducing machine throughput. This study introduces a fully automated MR contour ...

Benchmarking Patient Doses for Barium Fluoroscopy Procedures: A Single-Institution Study

Authors: Wilfred R Furtado, Gary Y. Ge, Jie Zhang

Affiliation: Department of Radiology, University of Kentucky, University of Kentucky

Abstract Preview: Purpose: The United Kingdom and several other countries already have well-established diagnostic reference levels (DRLs) for gastrointestinal fluoroscopic procedures, whereas the United States does no...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Comparison of Biological Effectiveness of COMS Eye Plaques with I-125 and Pd-103 Sources Using Equivalent Uniform RBE-Weighted Dose

Authors: Jonathan J. Chen, Alexei V. Chvetsov, Yulun He, Ramesh Rengan, Andrew Stacey, Kent Wallner

Affiliation: University of Washington and Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: To show that the RBE of low-energy photon sources used in COMS (Collaborative Ocular Melanoma Study) eye plaques compensates for protracted irradiation and attenuation of low-energy photons i...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Contrastive Learning and Hybrid CNN-Transformer Model for Unpaired MR Image Synthesis in Acute Cerebral Infarction

Authors: Kota Hirose, Daisuke Kawahara, Jokichi Kawazoe, Yuji Murakami

Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University

Abstract Preview: Purpose: Synthesizing medical images can address the lack of or unscanned medical images, reducing scanner time and costs. However, paired image scarcity remains a challenge for image synthesis. We pr...

Demographic Attributes of the Train-Test Sets and Their Impact on AI Performance: Medical Imaging Applications

Authors: Maryellen L. Giger, Fahd Hatoum, Robert Tomek, Heather M. Whitney

Affiliation: The University of Chicago

Abstract Preview: Purpose: To assess the importance of applying stratified sampling across demographic attributes (including age, sex, race, and ethnicity) when constructing training and testing datasets for ML-based d...

Development of Sphere Phantoms for Quantitative Evaluation of Computed Tomography Systems Resolution

Authors: Hyo-Min Cho, Changwoo Lee

Affiliation: Korea Research Institute of Standards and Science

Abstract Preview: Purpose: We develop sphere phantoms to assess spatial resolution of computed tomography (CT) systems and validate its usability using table-top X-ray experiment systems.
Methods: We manufactured sp...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Diffusion-Weighted MRI: An Early Biomarker for Treatment Response in MR-Guided Treatment of Rectal Cancer

Authors: Huiming Dong, Jonathan Pham, X. Sharon Qi, Ann Raldow

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: The study aimed to investigate longitudinal apparent diffusion coefficient (ADC) as an early biomarker of treatment response in patients with locally advanced rectal cancer (LARC) undergoing ...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko Salomón Alva Sánchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Eclipse AFI Manual Planning Versus Brainlab Auto-Planning: A Comparison of SRS Plan Quality

Authors: Dharmin D. Desai, Ellis Lee Johnson, Philip J. Kallenberg, Kapil M. Mishra

Affiliation: Spectrum Medical Physics, University of Kentucky, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: The “Ask For It” (AFI) manual optimization strategy has been shown to generate high quality SRS plans within Eclipse. The purpose of this work is to directly compare manually generated Eclips...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Enhancing Dose Conformity in Halcyon SRS Plans: A Novel Approach Using Optimized Collimator Angles and Sub-Arcs.

Authors: David Chighvinadze, Chieh-Wen Liu, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic Sandusky, Cleveland Clinic

Abstract Preview: Purpose: To explore the feasibility of using coplanar beams with collimator angle optimization for brain SRS plans with Halcyon system.
Methods: This study used a dataset of 26 patients with 2-3 br...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Finding the Best Match of 4D-CT Phases to Delineate Volumes for Bgrt

Authors: Resat Aydin, Joseph Barbiere, Brett Lewis, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
Accurately compensating for respiratory-induced tumor motion is critical in BgRT, where precise delineation of volumes ensures effective dose delivery. We propose an integrated approach th...

Follow-the-Leader Framework for Adaptable Target Segmentation in Radiotherapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study introduces a novel template-guided deep learning framework for primary gross tumor volume (GTVp) segmentation, addressing challenges posed by diverse tumor types and enabling a uni...

High Dose Rate Electron Beam Depth Dose Characterization

Authors: Fitria P Krisna, Mardon Limena, Supriyanto Ardjo Pawiro, Jhon H Saragih, Wahyu E. Wibowo, Poonam Yadav, Ummu M Zahro

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Radiation Oncology Dr. Cipto Mangunkusumo National Central Public Hospital, Department of Physics, Mathematics and Natural Sciences, University of Indonesia, Department of Radiotherapy, Mandaya Hospital, Department of Radiation Oncology, Mitra Keluarga Kenjeran Hospital, Department of Radiotherapy, Mandaya Royal Hospital, Radiation Oncology, Santosa Hospital

Abstract Preview: Purpose: To perform depth dose characteristics of High Dose Electron Beam and utility of various commercially available detectors.
Methods: The measurements were performed using an Elekta Versa HD ...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

HyperArcTM Automated Radiosurgery Planning Enables Accurate a Priori Isotoxic Prescription Dose Selection

Authors: Rex A. Cardan, Carlos E. Cardenas, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li, Rodney J. Sullivan, Natalie N. Viscariello, Christopher Willey

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: vBrain radiosurgery toxicity-rate is estimated via clinically-relevant isodose volume (IDV) thresholds according to HyTEC (e.g., V12Gy≤10cc). HyperArcTM (HA) automated planning allows accurat...

Image Quality Improvement Using a Patient-Specific Post-Trigger Delay Protocol for Coronary CT Angiography

Authors: Cecelia Brewington, Connor Edwards Miles All Leska-Kent, Kyrillos Grace, Katherine Hyde, Sabee Molloi, Shiva Mostafavi, Liqiang Ren, Alireza Shojazadeh, Justin Truong

Affiliation: Department of Radiology, UT Southwestern Medical Center, University of California, Irvine, University of Texas Southwestern

Abstract Preview: Purpose: To retrospectively assess image quality in coronary CT angiography (CCTA) using a patient-specific post-trigger delay (PTD) protocol, developed using half of the injection time plus a dispers...

Impact of Lung Density on Plan Quality and Delivery Parameters in Lung Stereotactic Body Radiation Therapy (SBRT) Plans

Authors: David Chighvinadze, Indra J. Das, Jeremy D. Donaghue, Kevin Stephans, Gregory Videtic, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic, Cleveland Clinic Sandusky, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Cleveland Clinic Fairview

Abstract Preview: Purpose:: Evaluate the impact of lung density variations on plan quality and delivery parameters in lung SBRT Plans.
Methods: For a hypothetical case with a real patient anatomy, three GTVs with vo...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

In-Silico Clinical Trials Enabled By Digital Twin Approach Can Accurately and Prospectively Predict Outcomes of Clinical Trials Combining Radiation and Systemic Therapy

Authors: Clemens Grassberger, David (Bo) McClatchy, Harald Paganetti

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Massachusetts General Hospital

Abstract Preview: Purpose: While randomized controlled trials (RCTs) are the gold standard for demonstrating efficacy, nearly 50% of late-stage clinical trials fail to meet their endpoint. Tools to study the design of ...

Initial Three-Year Machine Performance Assessment of a Superficial Radiation Therapy Unit

Authors: Vibha Chaswal, Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, William Romaguera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: To report machine performance of our superficial radiation therapy unit (SRT-100 Vision, Sensus Healthcare, Boca Raton, FL) for the first three years after commissioning of the unit.
Metho...

Knowledge-Based Online Adaptive Proton Stereotactic Ablative Radiotherapy (SABR) for Localized Prostate Cancer Using Gaussian Process Regression

Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...

Large Scale Deployment of a Tailored and Hybrid Educational Strategy for Wartime Capacity Building: Aapm/HUG/Uamp Initiative to Transition Ukraine from Co-60 to IMRT through a Comprehensive Medical Physics Training Program

Authors: Victoria Susan Ainsworth, Stephen M. Avery, Serhii Brovchuk, Thomas Brown, Sean A. Dresser, Matthew D. Goss, Viktor M. Iakovenko, Kelly Kisling, Nataliya Kovalchuk, Robert F. Krauss, Wilfred F. Ngwa, Jatinder R. Palta, Julie A. Raffi, Peter Allan Sandwall, Natalka Suchowerska, William Swanson, Shada J. Wadi-Ramahi, Ruslan Zelinskyi

Affiliation: Allegheny Hospital, Johns Hopkins University, Virginia Commonwealth University, Stanford University, O.O. Shalimov National Institute of Surgery and Transplantology, Department of Radiation Oncology, UT Southwestern Medical Center, School of Physics, The University of Sydney, MaineHealth, University of California, San Diego, Duke University, Emory University, University of Pennsylvania, University of Pittsburgh Medical Center, Medical Physics Department, Medical center of Yuriy Spizhenko, OhioHealth, University of Massachusetts Lowell, St. Francis Hospital

Abstract Preview: Purpose: The AAPM International Council, in collaboration with Help Ukraine Group (HUG) and Ukrainian Association of Medical Physicists (UAMP), developed a novel hybrid year-long training course to as...

MRI Radiomics-Based Machine Learning Model for Predicting BNCT Treatment Response in Glioblastoma

Authors: Huang Chi-Shiuan, Wu Chih-Chun, Hui-Yu Cathy Tsai, Chen Yan-Han, Chen Yi-Wei, Pan Yi-Ying

Affiliation: Institute of Nuclear Engineering and Science, National Tsing Hua University, Taipei Veterans General Hospital, Tri-Service General Hospital

Abstract Preview: Purpose:
This study aims to develop and validate a machine learning (ML) model based on MRI-derived radiomic features to predict progressive disease (PD) in glioblastoma (GBM) patients four months ...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Mechanistical Modeling of Radiation Response of Parotid in Head and Neck Cancer Radiotherapy

Authors: Rachel B. Ger, Xun Jia, Youfang Lai, Todd R. McNutt, Xingyi Zhao

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Radiotherapy (RT) plays an essential role for head and neck (HN) cancer treatment but often results in xerostomia due to salivary gland damage. It is important to mechanistically model the ra...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Multimodal Framework for Predicting Radiation-Induced Severe Acute Esophagitis in Esophageal Cancer

Authors: Yeona Cho, Chloe Min Seo Choi, Joseph O. Deasy, Jue Jiang, Jihun Kim, Jin Sung Kim, Nikhil Mankuzhy, Aneesh Rangnekar, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: University of Freibrug, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Memorial Sloan Kettering Cancer Center, Yonsei University

Abstract Preview: Purpose: We hypothesized that combining clinical, imaging, and radiotherapy dose-distribution features could increase predictive model accuracy in radiation-induced severe acute esophagitis (SAE) in e...

Novel AI-Powered Tool to Objectively Evaluate Brain Dose for Multi-Met Stereotactic Radiosurgery Optimization

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Richard A. Popple, Wenyin Shi, Rodney J. Sullivan, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: Objectively evaluating brain sparing as a plan-quality indicator for patients receiving stereotactic radiosurgery (SRS) to multiple metastases (multi-met) is complicated by variability in tar...

Novel Design for a Mechanically Tunable Ceramic Volume Resonator for 9.4T Pre-Clinical MRI

Authors: Victor B. Kassey, Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert

Affiliation: Dartmouth College

Abstract Preview: Purpose: High-resolution magnetic field uniformity is essential for quantitative and pre-clinical MRI research. Imaging uniformity is affected by the B0 field, which can be corrected using manual or a...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Pancrea-Seg-Net: A Semi-Supervised Deep Learning Framework for Pancreatic Tumor and Vessel Segmentation

Authors: Manju Liu, Ning Wen, Fuhua Yan, Yanzhao Yang, Zhenyu Yang, Haoran Zhang, Lei Zhang, Yajiao Zhang

Affiliation: Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Pancreatic ductal adenocarcinoma (PDAC) is a highly aggressive malignancy where precise segmentation of tumors and adjacent vessels is crucial for effective treatment planning. This study dev...

Photon-Counting CT Versus Dual Energy CT for Liver Fat Volume Fraction Assessment

Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou

Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...

Quantifying Respiratory Motion Effects in Lung Cancer Radiotherapy Using 4DCT Voxel Analysis

Authors: Chih-Chiang Chang, Chingyun Cheng, Ben Durkee, Minglei Kang, Elissa Khoudary, Yangguang Ma, Xuanqin Mou, YuFei Wang, Tengda Zhang, Wang Zhengda

Affiliation: Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Medical Physics, Columbia University, University of Pennsylvania, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study presents a voxel-based analysis method based on deformable image registration to accurately quantify respiratory-induced motion and deformation of both targets and organs at risk (...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Task Specific Image Quality Assessment Using Spectral Photon-Counting CT.

Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...

Water-Equivalent Thickness Mapping (WET-MAP) – a Potential Alternative to 4D Robust Optimization for Motion Management in Proton Treatment Planning

Authors: Duncan Henry Bohannon, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
4D robust optimization, incorporating additional images (e.g., maximum inhale/exhale phases), is commonly used to account for target motion in proton treatment planning. However, the incre...