Search Submissions 🔎

Results for "radiochromic film": 22 found

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Surface-Conforming Flexible Collimator for Improving Electron Radiotherapy

Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz

Affiliation: UT Health San Antonio

Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...

An Efficient, Low-Cost, and Accessible Film Dosimetry Scanning System

Authors: Parminder S. Basran, Wyatt Flanders, Skylar Sylvester

Affiliation: Cornell University

Abstract Preview: Purpose: To develop a reliable, efficient, and low-cost methodology for quantifying radiation doses using radiochromic film and a custom-built lightbox and to evaluate the system's performance compare...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Clinical Implementation of a Film Based Psqa System for SBRT on a 1.5T MR-Linac

Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal

Affiliation: Sunnybrook Health Sciences Centre

Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Cross Characterization of a 3D Gamma Camera and Ring Brachytherapy Applicator

Authors: Zachary R. Grelewicz, Kevin C. Jones, Yixiang Liao, Andrew Ogilvy, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To demonstrate the accuracy and QA application of a time-resolved 3D gamma camera, we measured the path traversed by the Ir-192 High-Dose-Rate (HDR) brachytherapy source passing through a rin...

Development of the First Benchtop X-Ray Flash System

Authors: Ruirui Dong, Gernot Echner, Peter Haering, Clarence King, Carlos Murillo, Gavin Poludniowski, Nicholas Sammut, Joao Seco, Steffen Seeber, Maria Francesca Spadea, Elpida Theodoridou

Affiliation: KIT, Department of Physics and Astronomy, Heidelberg University, Karolinska Institutet, DKFZ, University of Malta

Abstract Preview: Purpose:
The goal is to develop the first benchtop X-ray FLASH system based on a conventional small animal irradiator. The small animal irradiator will be modeled using a Monte Carlo toolkit for bo...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Enhanced Surface Dose Accuracy in Proton Treatment Planning: Optimizing External Volume HU Thresholding.

Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez

Affiliation: University of Miami

Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...

Evaluating the Impact of Beam Spot Spacing on Dose Rates and Field Uniformity for Small Animal Proton Ultra-High Dose Rate Irradiation

Authors: Jack Biondo, Audrey Magness, Anthony E. Mascia, Zhiyan Xiao, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center

Abstract Preview: Purpose: Proton FLASH-RT has shown promise reducing normal tissue toxicity while maintaining tumor control. However, in vivo experiments critically depend on achieving ultra-high dose rate (UHDR) and ...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Impact of Tracking By Jaws or Mlc on Treatment Accuracy in Synchrony Modality for Tomohelical Technique

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Modeling of Novel Converging Beam Radiotherapy System in Geant4 Montel Carlo Simulation

Authors: Dirk A Bartkoski, Leonard Che Fru, Benjamin Abraham Insley, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour, Aviad Schori, Ramesh C. Tailor

Affiliation: Empyrean Medical Systems, The University of Texas MD Anderson Cancer Center, Convergent-RnR, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose: A Geant4-based model was created for a G4BraggReflection process to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (CRnR...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Radiological Assessment of Radiochromic Film Models EBT3 and EBT4 in Proton Beams

Authors: Kuan Ling Chen, Jiajin Fan, Rao Khan, Robabeh Rahimi

Affiliation: University of Maryland, Inova Schar Cancer Institute, Howard University

Abstract Preview: Purpose: This study evaluates the dose response, energy dependency, sensitivity, reproducibility, temporal response, and LET dependency along and in the plane perpendicular to a clinical proton beam f...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...