Search Submissions 🔎

Results for "range verification": 29 found

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

An Automated Approach to Monitoring Clinical Protocols Against a Master Protocol

Authors: Jeremy Christophel, Zhihua Qi

Affiliation: Henry Ford Health

Abstract Preview: Purpose: To demonstrate a method to compare DICOM metadata from clinical scanners with institutional protocols as validation that clinical use matches the master protocol.
Methods: DICOM metadata i...

Analyzing Backlight Runtime and Corresponding Performance in Diagnostic Displays

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the correlation between the backlight runtime in diagnostic displays and their corresponding performance, which may aid in making informed decisions regarding the timi...

BEST IN PHYSICS MULTI-DISCIPLINARY: Evaluation of Spot-Level N-12 PET Imaging for Online Range Verification in Multi-Field Intensity Modulated Proton Therapy

Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos

Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen

Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...

BEST IN PHYSICS THERAPY: Population-Based Automated Organs-at-Risk Contouring Outlier Detection and Visualization without Requiring Patient-Specific Reference Contour

Authors: Rex A. Cardan, Carlos E. Cardenas, Quan Chen, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Yi Rong, Dennis N. Stanley, Natalie N. Viscariello, Libing Zhu

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, Mayo Clinic Arizona, University of Alabama at Birmingham

Abstract Preview: Purpose: Manual verification of organs-at-risk(OARs) delineations is a critical yet time-intensive process, often susceptible to unintentional oversights. To assist the reviewing process, a population...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Clinically Ready Simulation Package for Monitoring Gamma Hotspot Emission, and Detection in Patient Anatomy

Authors: Ananta Raj Chalise, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tool to investigate the PG emission during proton therapy and optimize ...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Development and Clinical Validation of an Analytical Approach for 3D Positron Emitter Distribution Prediction in Carbon Ion Therapy

Authors: Julia Bauer, Tianxue Du, Katia Parodi, Marco Pinto, Thomas Tessonnier

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose:
Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing irradiation-induced PE...

Dosex As a per-Pulse Uhdr and Conventional Electrometer Compatible with Sandard Clinical Probes

Authors: Petr Bruza, David J. Gladstone, Austin Sloop, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Health

Abstract Preview: Purpose: UHDR-specific probes are becoming available on the market but often demand high costs and long order times. The reduced sensitivity of these probes often imposes challenges when measuring con...

Dual-Modality Protoacoustic and Ultrasound Imaging for Real-Time Monitoring of Proton Therapy In Vivo

Authors: Kristina Bjegovic, Yong Chen, Lucia Rodriguez Gonzalez, Marti Roper, Liangzhong Xiang

Affiliation: University of California, Irvine, University of California Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is an increasingly popular cancer treatment due to its precision, enabled by the Bragg Peak (BP), which minimizes side effects. This profile necessitates in-patient localizatio...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Expert Verification of AI-Generated Cardiac Substructures and Dosimetric Differences between Auto-Contoured and Manually Delineated Contours

Authors: Stephen R. Bowen, Richard Cheng, Kylie Kang, Janice Kim, Ana Paula Santos Lima, Dominic A. Maes, Juergen Meyer, Karen Ordovas, Kerry Reding

Affiliation: Department of Radiation Oncology, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiology, University of Washington, Division of Cardiology, University of Washington, Department of Biobehavioral Nursing and Health Informatics, School of Nursing, University of Washington

Abstract Preview: Purpose: Artificial intelligence (AI)-based auto-segmentation tools can increase the efficacy and reproducibility of radiotherapy (RT) treatment planning. This study evaluates the quality of AI-genera...

First In Vivo Proton Beam Irradiation of Mice with Quasi-Real-Time Range Verification with the Sirmio PET Scanner

Authors: Niels Bassler, Jonathan Bortfeldt, Francesco Evangelista, Giulio Lovatti, Jasper Nijkamp, Rasmus Nilsson, Munetaka Nitta, Katia Parodi, Marco Pinto, Per R. Poulsen, Brita Singers Sørensen, Peter Thirolf, Erik Traneus, Taiga Yamaya

Affiliation: RaySearch Laboratories AB, National Institutes for Quantum Science and Technology, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: Within the SIRMIO project (Small Animal Proton Irradiator for Research in Molecular Image-Guided Radiation Oncology), we aimed to perform the first in vivo proton beam treatment with a dedica...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Investigation of a Novel Snout-Mounted Compton Camera System for Monitoring Dose Depth

Authors: Ananta Raj Chalise, Matthias K Gobbert, Hajar Moradmand, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, University of Maryland, Baltimore County, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: We are developing a novel Compton Camera (CC) system mounted orthogonally on the treatment nozzle for prompt gamma (PG) imaging-based proton range verification during treatment. This study in...

Knowledge-Based Three-Dimensional Dose Prediction for High Dose Rate Prostate Brachytherapy

Authors: Mojtaba Behzadipour, Suman Gautam, Tianjun Ma, Ikchit Singh Sangha, Bongyong Song, William Song, Kumari Sunidhi

Affiliation: UC San Diego, Virginia Commonwealth University

Abstract Preview: Purpose: This study aims to develop a knowledge-based voxel-wise dose prediction system using a convolutional neural network (CNN) for high-dose-rate (HDR) prostate brachytherapy and to evaluate its p...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

Objective Verification of Mechanical and Radiation Isocenters Independent of Setup

Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.

Abstract Preview: Purpose: The novel machine quality assurance (QA) device nüFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...

Patient-Specific Imaging Modality Agnostic Virtual Digital Twins Modeling Temporally Varying Digestive Motion

Authors: James M. Balter, Lando S. Bosma, Jorge Tapias Gomez, Nishant Nadkarni, Mert R Sanbuncu, William Paul Segars, Ergys D. Subashi, Neelam Tyagi, Harini Veeraraghavan

Affiliation: University of Michigan, The University of Texas MD Anderson Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Cornell University, University Medical Center Utrecht, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Develop patient-specific virtual digital twin (VDT) cohorts modeling physically realistic spatio-temporal gastrointestinal (GI) organs (stomach and duodenum) digestive motion.
Methods: Pat...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Radiopharmaceutical-Free Assessment of Tumor Vasculature Condition in Particle Therapy By Means of Range-Verification PET: A Feasibility Rat Study

Authors: Go Akamatsu, Han Gyu Kang, Chie Seki, Hitomi Sudo, Hideaki Tashima, Chie Toramatsu, Hidekatsu Wakizaka, Iwao Yamaya, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose:
Tumor oxygen status, which provides important information to optimize particle therapy, may constantly change during a treatment period of several weeks. However, it is impractical to perf...

Reproducibility of Target Position during Surface-Guided Breath-Hold Adaptive SBRT of Liver Cancer

Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

Visualization of Irradiation Field in Carbon-Ion Therapy By Openpet: Preliminary Analysis of Clinical Data

Authors: Go Akamatsu, Hiroaki Ikawa, Yuma Iwao, Han Gyu Kang, Masashi Koto, Hideyuki Mizuno, Akram Mohammadi, Makoto Shinoto, Minoru Tajiri, Hideaki Tashima, Chie Toramatsu, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In-beam positron emission tomography (PET), in which positron emitters produced through fragmentation reactions are visualized, is a practical method for range verification in particle therap...