A Real-Time 6 Degrees-of-Freedom Image Guided Radiation Therapy Technology Using Internal-External Motion Correlation Modelling

Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...

A Tumor Tracking Method in Surface-Guided Radiotherapy

Authors: Penghao Gao, Zejun Jiang

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: Real-time tumor tracking can effectively compensate for the impact of respiratory motion on dose distribution. We propose a patient-specific external-internal correlation model driven by opti...

Assessing the Need for Online Adaptive Prostate SBRT Using the MR-Linac

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Samuel Richter, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the necessity and potential benefits of online adaptive stereotactic body radiotherapy (SBRT) for prostate cancer using the ViewRay MR-Linac system. By leveraging real-ti...

Clinical Application of Biology-Guided Radiotherapy (BgRT) to Patient Having a Cardiac Implantable Electronic Device (CIED)

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...

Designing Impactful Radiotherapy Training for Skill Development and Long-Term Growth

Authors: Stephanie Bennett, Sean L. Berry, Caroline M. Colbert, Dustin J. Jacqmin, James A. Kavanaugh, Minsun Kim, Maura L. Kirk, Emily Kruse, Benjamin Li, Mu-Han Lin, Lindsey A. Olsen, Jose Carlos Pichardo, Justin R. Roper, Leah K. Schubert, Chunhao Wang, Sua Yoo

Affiliation: University of Wisconsin, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Abington - Jefferson Health, Mayo Clinic, University of Washington, University of Colorado Health, University of Colorado Denver, Department of Radiation Oncology, University of Washington and Fred Hutch Cancer Center, Duke University, Pichardo Physics LLC, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: As clinics in lower- and middle-income countries (LMICs) transition to advanced radiotherapy techniques like IMRT and VMAT, gaps in training can result in suboptimal planning. To help support...

Developing and Using Barcode-Reading Type Portable OCT Imaging System to Detect Surgical Margin

Authors: Dukagjin Blakaj, Zhilin Hu, Stephen Kang, Abberly Lott Limbach, Lanchun Lu, Henry Xiang, Jie Zhang

Affiliation: Pharostek, Department of Pediatrics, The Ohio State University, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiology, University of Kentucky, Department of Pathology, The Ohio State University, Department of Radiation Oncology, The Ohio State University, Department of Otolaryngology, The Ohio State University

Abstract Preview: Purpose: Detect surgical margin in vivo using an original barcode-reading type portable OCT imaging system.
Methods: We developed a barcode-reading type portable optical coherence tomography (OCT) ...

Development of an Innovative and Efficient KBP-Based Automated Method for IMRT Optimization

Authors: Somayeh Gholami, Saeedeh Ketabi, Jeremy Kunz, Ali Yousefi

Affiliation: Department of Radiation Oncology, University of Utah, University of Utah, Department of Management- Operations Research, University of Isfahan

Abstract Preview: Purpose: This paper aims to present a novel approach for automatic knowledge-based planning optimization for Intensity Modulated Radiotherapy, along with the two downsizing techniques for improving th...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Failure Mode and Effects Analysis (FMEA) on Use of Surface Guided Imaging

Authors: Victoria Noelle Bry, Tamara Egan, Eric C. Ford, Angelia Landers, Juergen Meyer

Affiliation: Fred Hutch Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) can improve patient safety, however, its complex integration may expose processes to increased risk of error. This work identifies potential failures f...

Feasibility of Real-Time Monitoring in Tumor Treating Fields Therapy Using Electrical Impedance Tomography: Analysis of Current Injection and Measurement Patterns

Authors: Sung Hwan Ahn, Yongha Gi, Jinju Heo, Jinyoung Hong, Yunhui Jo, Yousun KO, Hyeongjin Lim, Sang Yoon PARK, Myonggeun Yoon

Affiliation: Institute of Global Health Technology (IGHT), Korea University, Republic of Korea, Korea University, Samsung Medical Center

Abstract Preview: Purpose:
This study aims to evaluate the feasibility of real-time monitoring of conductivity changes induced by thermal variations during tumor treating fields (TTFields) therapy using Electrical I...

Feasibility of Using 68ga-PSMA for Biology-Guided Radiotherapy (BgRT) Treatment

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Neil Desai, Aurelie Garant, Orhan Oz, Elizeva Phillips, Rameshwar Prasad, Chenyang Shen, Robert Timmerman

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: This study reports findings from the first-in-human imaging-only trial evaluating the feasibility of using the novel PET tracer 68Ga-PSMA-11 (Illuccix) to guide external beam radiotherapy on ...

First Phantom Testing of Biology-Guided Radiotherapy for Sequential Integrated Boost Radiotherapy

Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...

Impact of IMRT Beam Scatter and Electronic Noise on Real-Time Kv and Fluoroscopy Image Quality

Authors: Wei Luo, Cameron Thayer-Freeman, Yifeng Zhao

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky

Abstract Preview: Purpose: Real-time Kilovoltage (kV) imaging has emerged as a powerful clinical aid, providing high-precision localization of moving targets during treatment. However, the Megavoltage (MV) treatment be...

Impact of Positron Emission Tomography (PET) Image Characteristics on Biology-Guided Radiotherapy (BgRT) Treatment Accuracy

Authors: Angela J Da Silva, Andrew Groll, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: PET-based biology-guided radiotherapy (BgRT) is a radiation therapy technique that uses PET imaging to deliver tracked dose to the tumor in real-time. We characterized the delivery accuracy o...

Improving Head and Neck Radiotherapy Accuracy through Real-Time Volumetric Imaging Using a Kalman Filter Approach

Authors: Youssef Ben Bouchta, Chen Cheng, Owen Thomas Dillon, Mark Gardner, Paul J. Keall, Purnima Sundaresan

Affiliation: Radiation Oncology Network, Western Sydney Local Health District, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: There are three clinical motivations for real time IGRT in head and neck cancer radiation therapy: (1)50% of patients experience anxiety from the patient mask (2)patient motion still occurs d...

Linac Based Dose-Escalated Radiation Therapy for Pancreatic Cancer: Assessing Respiratory Motion

Authors: Neal Andruska, Lianna D. DiMaso-Myers

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To provide details on how our clinic assesses respiratory motion during treatment of a pancreatic adenocarcinoma during dose escalated radiation therapy on a linear accelerator with the aid o...

Mask-Less Adaptable Headrest for Head-and-Neck Radiotherapy

Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater

Affiliation: Saint Louis University

Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patients’ setups. MAHR complements current image-guidance...

One Year Experience of Biology-Guided Radiotherapy (BgRT) on PET-Linac in an Academic Center

Authors: Shahed Badiyan, Girish Bal, Thomas I. Banks, Bin Cai, Tu Dan, Aurelie Garant, Andrew R. Godley, Steve Jiang, Orhan Oz, Arnold Pompos, Rameshwar Prasad, Chenyang Shen, David Sher, Robert Timmerman, Kenneth Westover

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) is a novel FDA-cleared technology for treating lung and bone tumors based on 18F-FDG PET uptake. This study summarizes the first-year experience treating 29...

Python-Based Patient Coaching System for Gated Treatment Delivery

Authors: Usha Robins Abraham, Monique Lockhart Chisem, Alonso N. Gutierrez, Janos Juhasz, Michael Leyva, Carlos M. Rivera, Ranjini P. Tolakanahalli, Vanessa Vega Fleites

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health

Abstract Preview: Purpose:
Accurate breath hold (BH) gated treatments rely heavily on patient cooperation. Maintaining consistent breath-hold levels can be challenging for patients. Surface image guidance (SGRT) is ...

Quantitative 3D Surface Mapping of Cherenkov Images for Real-Time Beam Deviation Detection in Radiotherapy

Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone

Affiliation: Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Cherenkov images are two-dimensional projections of the surface light emissions, and lack spatial information about the radiotherapy beam delivery. We implement the first fusion of Cherenkov ...

Quantitative Evaluation of Eclipse’s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...

Real-Time Fully Automated IMRT Planning without Optimization Process Using a Two-Step AI Framework

Authors: Daisuke Kawahara, Takaaki Matsuura, Yuji Murakami, Ryunosuke Yanagida

Affiliation: Hiroshima High-Precision Radiotherapy Cancer Center, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima

Abstract Preview: Purpose: In recent years, automation in radiation therapy planning using AI has gained significant attention to reduce the workload of treatment planners. Adaptive Radiation Therapy (ART), as a new fo...

Retrospective Study Using Avi Planner for Head and Neck Cancer Cases: Our Experience at Nsia-Luth Cancer Center, South - West Nigeria

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba

Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center

Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...