Search Submissions 🔎

Results for "real tracking": 44 found

A Conditional Point Cloud Diffusion Model for Deformable Liver Motion Tracking Via a Single Arbitrarily-Angled X-Ray Projection (PCD-Liver)

Authors: Yunxiang Li, Hua-Chieh Shao, Chenyang Shen, Jing Wang, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Accurate liver deformable motion tracking is essential in image-guided radiotherapy to enable precise tumor targeting during treatment. We developed a conditional point cloud diffusion model ...

A Dynamic Reconstruction and Motion Estimation Framework for Cardiorespiratory Motion-Resolved Real-Time Volumetric MR Imaging (DREME-MR)

Authors: Jie Deng, Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Based on a 3D pre-treatment MRI scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a moti...

A Hybrid-PCA Based Accelerated MR Method for Real-Time Target Tracking and Motion Management

Authors: B. Gino Fallone, Keith D. Wachowicz, Mark G. Wright, Jihyun Yun

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com

Abstract Preview: Purpose: This work focusses on a hybrid Principal Component Analysis (PCA) based MR acceleration method for prospectively acquired undersampled data on a hybrid MR-Linac system for real-time target-tr...

A Mechatronic Biopsy Guidance System for an Integrated 3D TRUS with Prostate-Specific PET System

Authors: Jeffrey Bax, Ian A. Cunningham, Aaron Fenster, Lori Gardi, Sule Karagulleoglu Kunduraci, Alla Reznik, David Tessier

Affiliation: Robarts Research Institute, Imaging Research Laboratories, Robarts Research Institute, Lakehead University

Abstract Preview: Purpose: Image-guided biopsy is critical for early diagnosis of prostate cancer (PCa), the most common cancer in men worldwide. While the prostate-specific PET (P-PET) system offers enhanced sensitivi...

A Method to Estimate Tumor Motion with Respiration Based on CBCT Projections

Authors: Jie Liu

Affiliation: Inova Health System

Abstract Preview: Purpose:
The respiratory signal commonly acquired by using external surrogates or detecting the diaphragm position only represents the phase information and has poor correlation with the tumor moti...

A Real-Time Framework for Fiducial Tracking and Intrafraction Motion Assessment of Cyberknife in Stereotactic Body Radiation Therapy for Liver Cancer

Authors: Ruiyan Du, Mingzhu Li, Ying Li, Wei Liu, Shihuan Qin, Yiming Ren, Biao Tu, Hui Xu, Lian Zhang, Xiao Zhang, Zengren Zhao

Affiliation: Department of General Surgery, Hebei Key Laboratory of Colorectal Cancer Precision Diagnosis and Treatment, The First Hospital of Hebei Medical University, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Mayo Clinic, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Fiducial tracking is widely used in CyberKnife to dynamically guide the gantry for moving target like liver cancer stereotactic body radiation therapy (SBRT). This study developed a robust fr...

A Tumor Tracking Method in Surface-Guided Radiotherapy

Authors: Penghao Gao, Zejun Jiang

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: Real-time tumor tracking can effectively compensate for the impact of respiratory motion on dose distribution. We propose a patient-specific external-internal correlation model driven by opti...

AI-Powered Real-Time x-Ray Guided Tracking to Improve Stereotactic Arrythmia Radioablation: Proof of Principle

Authors: Vicky Chin, Mark Gardner, Nicholas Hindley, Paul J. Keall, Adam Mylonas

Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: Stereotactic Arrhythmia Radioablation (STAR) is a non-invasive method to treat cardiac arrhythmias by targeting aberrant electrical conduction regions in the heart. Targeting is challenging g...

BEST IN PHYSICS IMAGING: Population-Based Cardio-Respiratory Motion Model to Simulate 4D CT Angiography and 2D+t Fluoroscopy for Percutaneous Coronary Intervention

Authors: Debarghya China, Junghoon Lee, Ali Uneri

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins Univ

Abstract Preview: Purpose: This study aims to develop a population-based cardio-respiratory motion model and apply it to patient-specific 3D CTA to simulate 4D CTA and 2D+t fluoroscopy sequences. The developed motion m...

Brain Vessel Segmentation and Tracking in Longitudinal Glioblastoma MRI Scans

Authors: Evan Calabrese, Edward Robert Criscuolo, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose: Glioblastoma (GBM) is the most common and aggressive form of brain cancer. Deformable image registration (DIR) is a powerful tool to compute anatomical changes in longitudinal MRI scans, whic...

Combining Flat-Panel Imaging and Internal BB Markers for Precise HDR Brachytherapy Source Localization

Authors: Yibin Ling, Qihui Lyu, Ke Sheng

Affiliation: University of California Berkeley, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
High Dose Rate (HDR) brachytherapy enables radiation to concentrate on the tumor by sending the high-dose-rate radioactive source directly to the treatment site. On the other hand, the sha...

Deep Learning-Based Denoising for Template Matching in Real-Time Tumor Tracking Using Kv Scattered X-Ray Imaging

Authors: Weikang Ai, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Real-time tumor tracking is critically important for respiratory motion management for lung cancer radiotherapy. A previously proposed application of a photon counting detector involves measu...

Deep Learning-Based Eye Monitoring and Tracking System for Ocular Proton Therapy in a Regular Gantry Room

Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai

Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...

Deep Learning-Based Segmentation Using Cine Epid Images for Real-Time Tumor Monitoring

Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita

Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital

Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...

Deep-Dive Comparative Assessment between Digitally Reconstructed Radiographs and X-Ray Digital Radiographs from Lung CT Scans

Authors: Xinyi Fu, Dan Ruan, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Digitally reconstructed radiographs (DRRs) are easy to generate and widely used to establish research protocols in pulmonary diagnosis and image-guided radiotherapy tasks. A question remai...

Development of a Robust 3D-Ultrasound (3DUS) Quality Assurance (QA) Framework for a Real-Time Needle-Tracking System in HDR GYN Brachytherapy

Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity

Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Development of an Orthogonal X-Ray Projections-Guided Cascading Volumetric Reconstruction and Tumor-Tracking Model for Adaptive Radiotherapy

Authors: Penghao Gao, Zejun Jiang, Huazhong Shu, Linlin Wang, Gongsen Zhang, Jian Zhu

Affiliation: Laboratory of Image Science and Technology, Key Laboratory of Computer Network and Information Integration, Southeast University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: We propose a cascading framework for time-varying anatomical volumetric reconstruction and tumor-tracking, guided by onboard orthogonal-view X-ray projections.
Methods: We employe multiple...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dynamic Winston-Lutz Testing for FFF Beams

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...

Dynamic X-Ray Acoustic Computed Tomography (XACT)

Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan

Affiliation: University of California, Irvine

Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...

Enhancing the Capability of Intrafractional Target Tracking for Prostate SBRT Via Tissue Decomposition Imaging

Authors: Sarah Burleson, Antonio L. Damato, Yabo Fu, Laura Happersett, Tianfang Li, Xiang Li, Himanshu Nagar, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: An iodinated hydrogel perirectal spacer, injected between the prostate and rectum, reduces rectal high-dose exposure during prostate SBRT. We assessed the feasibility of tracking the spacer a...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluating Phantom Usability for Thermal Imaging Localization in Radiation Therapy

Authors: Nema Bassiri, Kristen A. Duke, Neil A. Kirby, Thomas Wilson Klender, Christien Kluwe, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz, Michelle de Oliveira

Affiliation: Miami Cancer Institute, University of Texas HSC San Antonio, UT Health San Antonio

Abstract Preview: Purpose: Determine the practical usability for three phantoms to be used with the ExacTrac Dynamic thermal imaging system. Thermal-guided imaging can be used for inter and intra motion management, pat...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Frameless and Maskless Stereotactic Radiosurgery: Evaluating a Novel Robotic Head Motion Compensation Device

Authors: Michelle Alonso-Basanta, Carl Denis, Wenbo Gu, Xinmin Liu, Ahmad Sakaamini, Rodney D. Wiersma

Affiliation: UCLA, University of Pennsylvania, CDR Systems

Abstract Preview: Purpose: Stereotactic radiosurgery (SRS) is a non-invasive technique used to treat functional abnormalities and small brain tumors. Traditional SRS relies on a rigidly fixed metal head ring, causing d...

Impact of Tracking By Jaws or Mlc on Treatment Accuracy in Synchrony Modality for Tomohelical Technique

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...

Improving Head and Neck Radiotherapy Accuracy through Real-Time Volumetric Imaging Using a Kalman Filter Approach

Authors: Youssef Ben Bouchta, Chen Cheng, Owen Thomas Dillon, Mark Gardner, Paul J. Keall, Purnima Sundaresan

Affiliation: Radiation Oncology Network, Western Sydney Local Health District, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: There are three clinical motivations for real time IGRT in head and neck cancer radiation therapy: (1)50% of patients experience anxiety from the patient mask (2)patient motion still occurs d...

Motion Correction-Driven Patient-Specific 2D Cine MRI-Based Dynamic Volumetric Reconstruction for MRI-Guided Radiotherapy Intra-Fractional Motion Monitoring

Authors: Karyn A Goodman, Yang Lei, Tian Liu, D. Michael Lovelock, Charlotte Elizabeth Read, Jing Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Real-time volumetric MRI is essential for precise motion management in MRI-guided radiotherapy (MRIgRT). While 2D Cine MRI offers high temporal resolution for motion tracking, it inherently l...

Optimizing Motion Management QA: Clinical Integration of Aapm TG-306 for the Radixact Synchrony System

Authors: Hulya Ozdemir Buss, Jeffrey Geiger, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The Radixact Synchrony system integrates real-time motion tracking and compensates to improve treatment accuracy for moving targets. This study presents a streamlined and efficient quality as...

PET Guided Radiation Therapy for Large Planning Target Volume Expansions of Small PET-Active Gross Tumor Volumes

Authors: Sarah Dumont, Trevor Ketcherside, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose:
The RefleXion X1 SCINTIX algorithm convolves beam fluence with real-time PET distributions for tracking and plan adaptation, but radiotherapy Planning Target Volumes (PTVs) are often signi...

Patient-Specific Orthogonal Projection Based Real-Time Volumetric X-Ray Imaging for Proton Therapy

Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...

Patient-Specific Ultra-Sparse k-Space Reconstruction Using Motion Decomposition and Sinusoidal Representation Networks for Dynamic Volumetric MRI in Radiotherapy

Authors: Karyn A Goodman, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Qian Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Beth Israel Deaconess Medical Center

Abstract Preview: Purpose: Accurate motion management in MRI-guided radiotherapy (MRIgRT) relies on real-time volumetric MRI to track intra-fractional anatomical changes. Dense k-space sampling, while capable of produc...

Prior-Model-Free Dynamic CBCT Reconstruction Via Combined Optical Surface and X-Ray Imaging

Authors: Hua-Chieh Shao, Guoping Xu, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Advancements in onboard X-ray hardware allow high-quality CBCT imaging with a short scan time (~6s for Varian HyperSight), enabling CBCT-based dose calculation and treatment planning. Howe...

Prostate Dosimetric Comparison between Cyberknife and Radixact Modalities Using Precision and Raystation Planning Systems

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: The Accuray Synchrony real-time motion fiducial tracking solution allows for prostate stereotactic treatment on both Cyberknife and Radixact machines. In our radiotherapy department, two solu...

Reliable Markerless Lung Tumor Tracking with Built-in Patient-Specific Quality Assurance

Authors: Weixing Cai, Laura I. Cervino, Qiyong Fan, Yabo Fu, Tianfang Li, Xiang Li, Jean M. Moran, Hai Pham, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: AAPM Task Group Report 273 emphasizes the importance of rigorous validation to ensure the generalizability and robustness of machine learning-based clinical tools before their implementation ...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Towards Real-Time Marker-Less Prostate Tracking on Standard Radiation Therapy Systems

Authors: Freeman Jin, Paul J. Keall, Alistair MacDonald, Adam Mylonas, Chandrima Sengupta

Affiliation: Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Image X Institute, School of Health Sciences, University of Sydney

Abstract Preview: Purpose: During radiation therapy, tumours in the prostate may move from the planned treatment position, leading to significant dose deviations above clinical tolerances Surveys have indicated the nee...

Towards Real-Time Radiotherapy Monitoring By Cherenkov Imaging: Applications of Patient-Specific Bio-Morphological Features Segmented Via Deep Learning

Authors: Petr Bruza, Yao Chen, David J. Gladstone, Lesley A Jarvis, Brian W Pogue, Kimberley S Samkoe, Yucheng Tang, Shiru Wang, Rongxiao Zhang

Affiliation: NVIDIA Corp, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri, University of Wisconsin - Madison

Abstract Preview: Purpose: Cherenkov imaging provides real-time visualization of megavoltage radiation beam delivery during radiotherapy. Patient-specific bio-morphological features, such as vasculature, captured in th...

Two-Element Complementary Sensor for out-of-Plane Tracking in MR-Guided Radiotherapy

Authors: Zhaohui Han, Piotr Zygmanski

Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: Real-time motion tracking/gating are oftentimes limited to a single sagittal plane on many magnetic resonance linear accelerators (MR-Linac). Out-of-plane motion is therefore difficult to det...

Using AI Enables Real-Time Markerless Tracking of Soft Tissue Tumors on Conventional Linacs

Authors: Mark Gardner

Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: N/A...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...

“See” through Surface: Transforming Surface Imaging into a Real-Time Three-Dimensional Imaging Solution for Intra-Treatment Image Guidance

Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...