Search Submissions 🔎

Results for "reconstruction tracking": 24 found

4D CBCT Dynamic Images Recovery Using a 4D Neural Network

Authors: Ziheng Deng, Yao Hao, Runping Hou, Deshan Yang, Jun Zhao, Yufu Zhou

Affiliation: Department of Radiation Oncology, Duke University, School of Biomedical Engineering, Shanghai Jiao Tong University, Washington University School of Medicine, Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: 4D CBCT has been developed to provide dynamic images for image-guided radiation therapy. However, as projection data are sorted into sparse and clustered phase-specific bins, 4D CBCT images a...

A Dynamic Reconstruction and Motion Estimation Framework for Cardiorespiratory Motion-Resolved Real-Time Volumetric MR Imaging (DREME-MR)

Authors: Jie Deng, Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Based on a 3D pre-treatment MRI scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a moti...

A Hybrid Transformer-CNN for Tracking-Free 3D Ultrasound Volume Reconstruction from 2D Freehand Scans

Authors: Wenfeng He, Tian Liu, Pretesh Patel, Richard L.J. Qiu, Keyur Shah, Tonghe Wang, Xiaofeng Yang, Chulong Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Emory University, Medical Physics Graduate Program, Duke Kunshan University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study introduces a tracking-free approach to reconstruct 3D ultrasound (US) volumes from 2D freehand US scans. By eliminating the reliance on external tracking systems, this method aims ...

A Hybrid-PCA Based Accelerated MR Method for Real-Time Target Tracking and Motion Management

Authors: B. Gino Fallone, Keith D. Wachowicz, Mark G. Wright, Jihyun Yun

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com

Abstract Preview: Purpose: This work focusses on a hybrid Principal Component Analysis (PCA) based MR acceleration method for prospectively acquired undersampled data on a hybrid MR-Linac system for real-time target-tr...

A Real-Time Framework for Fiducial Tracking and Intrafraction Motion Assessment of Cyberknife in Stereotactic Body Radiation Therapy for Liver Cancer

Authors: Ruiyan Du, Mingzhu Li, Ying Li, Wei Liu, Shihuan Qin, Yiming Ren, Biao Tu, Hui Xu, Lian Zhang, Xiao Zhang, Zengren Zhao

Affiliation: Department of General Surgery, Hebei Key Laboratory of Colorectal Cancer Precision Diagnosis and Treatment, The First Hospital of Hebei Medical University, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Mayo Clinic, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Fiducial tracking is widely used in CyberKnife to dynamically guide the gantry for moving target like liver cancer stereotactic body radiation therapy (SBRT). This study developed a robust fr...

A Setup and Workflow for Fully Automated Electromagnetic Tracking-Based Implant Reconstruction in Intraoperative Prostate HDR Brachytherapy

Authors: Ioannis Androulakis, Miranda E.M.C. Christianen, Jérémy Godart, Mischa Hoogeman, Inger-Karine K. Kolkman-Deurloo, Lorne Luthart, Remi A. Nout, Henrike Westerveld

Affiliation: Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
Despite the advantages of transrectal ultrasound-based treatment planning for HDR prostate cancer brachytherapy which allows on-line treatment delivery in the intraoperative setting, it is...

Afterloader Integrated Electromagnetic Tracking Can be Used to Accurately Define and Assess the Dwell Position Model of Venezia™ Gynaecological Brachytherapy Applicators

Authors: Ioannis Androulakis, Jérémy Godart, Mischa Hoogeman, Inger-Karine K. Kolkman-Deurloo, Remi A. Nout, Robin Straathof, Henrike Westerveld, Myra van Laar

Affiliation: Department of BioMechanical Engineering, Delft University of Technology, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
In brachytherapy for gynaecological cancers using intracavitary applicators, implant reconstruction is commonly performed using applicator libraries. These libraries contain applicator geo...

Comparison of Respiratory Motion between 4D-MR and 4D-CT in Compression Belt Patients

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...

Deep Learning-Based Eye Monitoring and Tracking System for Ocular Proton Therapy in a Regular Gantry Room

Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai

Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...

Development of a Whole-Body Blood Flow Framework Based on the Icrp Blood Phantom

Authors: Jung Han Nam, Wonmo Sung

Affiliation: Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract Preview: Purpose: This study aims to develop a whole-body blood flow framework based on the ICRP 145 standard vascular phantom to simulate the spatiotemporal trajectories of blood cells in the human vasculatur...

Development of an Orthogonal X-Ray Projections-Guided Cascading Volumetric Reconstruction and Tumor-Tracking Model for Adaptive Radiotherapy

Authors: Penghao Gao, Zejun Jiang, Huazhong Shu, Linlin Wang, Gongsen Zhang, Jian Zhu

Affiliation: Laboratory of Image Science and Technology, Key Laboratory of Computer Network and Information Integration, Southeast University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: We propose a cascading framework for time-varying anatomical volumetric reconstruction and tumor-tracking, guided by onboard orthogonal-view X-ray projections.
Methods: We employe multiple...

Dynamic X-Ray Acoustic Computed Tomography (XACT)

Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan

Affiliation: University of California, Irvine

Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...

Eye-Tracking Analysis of Radiologist Preferences in PET Imaging: Comparing 5-Ring and 6-Ring Detector Configurations

Authors: Samuel L. Brady, Joseph G. Meier, Elanchezhian Somasundaram, Andrew T Trout

Affiliation: Cincinnati Children's Hospital Medical Ctr, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To analyze eye-tracker gaze data for insights into radiologists’ areas of focus in an observer study of whole-body PET images.
Methods:
For a comparative study of dose matched PET im...

Latent Diffusion for 3D CT Reconstruction from Biplanar X-Rays

Authors: Guha Balakrishnan, Osama R. Mawlawi, Yiran Sun, Ashok Veeraraghavan

Affiliation: RICE University, UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Previous deep learning (DL) techniques such as X2CT-GAN [1] has shown great promise in reconstructing realistic CT volume from biplanar X-rays, however they introduce numerous artifacts in...

Leveraging Photon Counting Detector CT and Advance Reconstructions to Improve the Accuracy of Vessel Tracing in Prostate Artery Embolization

Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...

Motion Correction-Driven Patient-Specific 2D Cine MRI-Based Dynamic Volumetric Reconstruction for MRI-Guided Radiotherapy Intra-Fractional Motion Monitoring

Authors: Karyn A Goodman, Yang Lei, Tian Liu, D. Michael Lovelock, Charlotte Elizabeth Read, Jing Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Real-time volumetric MRI is essential for precise motion management in MRI-guided radiotherapy (MRIgRT). While 2D Cine MRI offers high temporal resolution for motion tracking, it inherently l...

Patient-Specific Orthogonal Projection Based Real-Time Volumetric X-Ray Imaging for Proton Therapy

Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...

Patient-Specific Ultra-Sparse k-Space Reconstruction Using Motion Decomposition and Sinusoidal Representation Networks for Dynamic Volumetric MRI in Radiotherapy

Authors: Karyn A Goodman, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Qian Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Beth Israel Deaconess Medical Center

Abstract Preview: Purpose: Accurate motion management in MRI-guided radiotherapy (MRIgRT) relies on real-time volumetric MRI to track intra-fractional anatomical changes. Dense k-space sampling, while capable of produc...

Prior-Adapted Progressive Motion-Resolved CBCT Reconstruction Using a Dynamic Reconstruction and Motion Estimation Method

Authors: Hua-Chieh Shao, You Zhang, Ruizhi Zuo

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cone-beam CT (CBCT) provides on-board patient anatomy for image guidance and treatment adaptation in radiotherapy. However, to compensate for respiration-induced anatomical motion, motion-res...

Prior-Model-Free Dynamic CBCT Reconstruction Via Combined Optical Surface and X-Ray Imaging

Authors: Hua-Chieh Shao, Guoping Xu, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Advancements in onboard X-ray hardware allow high-quality CBCT imaging with a short scan time (~6s for Varian HyperSight), enabling CBCT-based dose calculation and treatment planning. Howe...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Toward Harmonized AI-Based Quantitative CT: A Voxel-Printed, Patient Specific Phantom for Cross-Platform Harmonization

Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...

“See” through Surface: Transforming Surface Imaging into a Real-Time Three-Dimensional Imaging Solution for Intra-Treatment Image Guidance

Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...