Search Submissions 🔎

Results for "reference assessment": 28 found

A Clarification on the Bandwidth Difference Method for MRI B0 Homogeneity Assessment

Authors: Christina Brunnquell, Daniel Vergara, Joseph Everett Wishart

Affiliation: University of Minnesota, University of Washington

Abstract Preview: Purpose: To propose and validate a correction to the bandwidth difference method presented in Task Group Report No. 325 for quantifying static magnetic field homogeneity (ΔB0).
Methods: A clarifica...

A New Voxel-Based Similarity Approach for Assessing Contour Similarity and Clinical Dosimetric Effect

Authors: Shari Damast, Svetlana Kuznetsova, Christopher J. Tien

Affiliation: Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Current contour similarity evaluation approaches (Dice Similarity Coefficient, Mean Distance to Agreement) are limited to geometric agreement without assessment of ultimate dosimetric impact....

A No-Reference Medical Image Quality Assessment Method Based on Automated Distortion Recognition Technology: Application to Preprocessing in MRI-Guided Radiotherapy

Authors: Jiayun Chen, Shengqi Chen, Yuan Tang, Zilin Wang, Guohua Wu, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, School of Electronic Engineering, Beijing University of Posts and Telecommunications, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose:
To develop a novel no-reference image quality assessment (NRIQA) method for evaluating the effectiveness of image preprocessing in MRI-guided radiotherapy (MRIgRT), thereby enhancing clini...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

A Self-Supervised Deep Learning Approach for Automatic Identification and Metal Artifact Reduction in Cone-Beam CT for Brachytherapy

Authors: Rani Anne', Wenchao Cao, Yingxuan Chen, Wookjin Choi, Firas Mourtada, Yevgeniy Vinogradskiy

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: In-room mobile cone-beam CT (CBCT) is emerging to enhance high-dose-rate (HDR) brachytherapy workflow using on-demand imaging. However, metal artifacts from X-ray markers inside gynecological...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

Assessment of Daily Target Volume and Dose Variations in Adaptive MR-Guided Radiotherapy for Pancreatic Cancer Patient

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose:
Pancreatic cancer poses therapeutic challenges due to the proximity of critical organs, requiring precise radiotherapy. Magnetic resonance (MR)-guided linear accelerators provide daily ima...

Assessment of Deep Learning Models for 3D Dose Prediction in Prostate Cancer SIB-IMRT Using MR-Linac

Authors: Hao-Wen Cheng, Jonathan G. Li, Chihray Liu, Wen-Chih Tseng, Guanghua Yan

Affiliation: University of Florida

Abstract Preview: Purpose: This study develops and evaluates deep learning (DL) models for predicting 3D dose distributions in simultaneous integrated boost (SIB) prostate cancer treatment using the Elekta Unity MR-Lin...

Assessment of the Auto Registration Feature of the PET/CT Linac Used for Biology Guided Radiation Therapy (BGRT)

Authors: Emily Hansen, Tyler Kaulfers, Alois M. Ndlovu, Francia Romero, Niara Rowe, Roland Teboh

Affiliation: Montefiore Einstein University Hospital, Hackensack University Medical Center

Abstract Preview: Purpose: Daily use and reliance on the auto registration feature requires a performance check. Clinical application of auto registration is performed without a selected region of interest (ROI), requi...

Automation of Clinical Protocol Imports for Treatment Planning System Version Update Compatibility

Authors: Michael Ashenafi, Mario Ramos Gallardo, Amy Herman, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: Updates to the Varian Eclipse Treatment Planning System (TPS) have introduced new objects to replace pre-existing Clinical Protocols to aide clinicians in plan quality assessment. We have cre...

Can AI Agent be a Good Judge for Online Adaptive Radiotherapy Plan Evaluation?

Authors: Steve B. Jiang, Mu-Han Lin, Dan Nguyen, Beiqian Qi, Daniel Yang, Ying Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Online adaptive radiotherapy (oART) is a resource-intensive workflow requiring significant time and effort required from clinicians, particularly for the online evaluation of plan quality....

Clinical Assessment of Synthetic CT in MR-Only Brain Radiotherapy

Authors: Ergun E. Ahunbay, Colette Gage, Abdul Kareem Parchur, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: AI-generated synthetic CT (sCT) images address challenges with prior sCT approaches, including atlas- and threshold-based methods. Commercial AI-based sCT tools have been introduced. This wor...

Creation of Customized Workflows in a New Surface-Guided Radiation Therapy (SGRT) System

Authors: Sorour Hosseini, YuHuei Jessica Huang, Jeremy Kunz, Nicholas Pierre Nelson, Ryan G. Price, Prema Rassiah, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To investigate the feasibility and clinical implications of creating customized workflows in a new SGRT system: LUNA 3D (LAP, Florida).
Methods: Three clinical SGRT workflows were designed...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko Salomón Alva Sánchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Dosinme: A 3D Visualization Platform for Internal Dosimetry and Radionuclide Behavior in Computational Human Phantoms

Authors: Lotem Buchbinder Shadur, Shaheen Dewji, Martin Graffigna, Alejandro Rafael Martinez, Emmanuel Mate-Kole, Antonio McClain, Samuel Taylor, Jeffrey Wang

Affiliation: Student, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: DosInMe is an internal dosimetry visualization tool developed by the Radiological Engineering, Detection, and Dosimetry Laboratory at Georgia Tech to assist researchers and professionals in v...

Emulating Human Perception of Low-Dose CT Image Quality Via Deep Generative Models

Authors: Jongduk Baek, Jooho Lee, Adam S. Wang

Affiliation: Stanford University, Yonsei University

Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...

Enhanced Lung Function Assessment through Machine Learning Analysis of 4DCT Subregional Respiratory Dynamics

Authors: Jing Cai, Zhi Chen, Hong Ge, Yu-Hua Huang, Bing Li, Zihan Li, Ge Ren

Affiliation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University and Henan Cancer Hospital

Abstract Preview: Purpose: Algorithms based on subregional respiratory dynamics (SRD) capture spatiotemporal heterogeneity in the ventilation process, though rely on empirical modelings to map surrogate ventilation. Gi...

Establishing a Protocol for Quality Assessment of Ultrasound Shear Wave Elastography (SWE) and Application to a Musculoskeletal (MSK) Task

Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...

Eye-Tracking Analysis of Radiologist Preferences in PET Imaging: Comparing 5-Ring and 6-Ring Detector Configurations

Authors: Samuel L. Brady, Joseph G. Meier, Elanchezhian Somasundaram, Andrew T Trout

Affiliation: Cincinnati Children's Hospital Medical Ctr, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To analyze eye-tracker gaze data for insights into radiologists’ areas of focus in an observer study of whole-body PET images.
Methods:
For a comparative study of dose matched PET im...

High-Resolution Limited-Angle CBCT Image Reconstruction for Non-Coplanar Radiation Therapy Via Dual-Domain Ordered-Subset Neural Representation with Prior Embedding (DDOS-NeRP)

Authors: Yu Gao, Lei Xing, Siqi Ye

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) scans are often the only option for non-coplanar radiation therapy to prevent potential mechanical collisions. However, the consecutive angular occlusion of pr...

Improving the Robustness of AI-Based Detection and Segmentation for Brain Metastasis By Optimizing Loss Function and Multi-Dataset Training

Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte

Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine

Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...

Integrating Knowledge-Based Planning with Ethos 2.0 for High-Quality Online Adaptive Lung SABR

Authors: Shahed Badiyan, Chien-Yi Liao, Mu-Han Lin, Dan Nguyen, Justin D. Visak, Hui Ju Wang, Brien Timothy Washington, Kenneth Westover, Yuanyuan Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Knowledge-based planning (KBP) plays a crucial role in improving treatment plans by leveraging previous clinical data to guide new cases. KBP is applied to the Ethos 2.0 Intelligent Optimizat...

Linac Based Dose-Escalated Radiation Therapy for Pancreatic Cancer: Assessing Respiratory Motion

Authors: Neal Andruska, Lianna D. DiMaso-Myers

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To provide details on how our clinic assesses respiratory motion during treatment of a pancreatic adenocarcinoma during dose escalated radiation therapy on a linear accelerator with the aid o...

Novel Fast Cone-Beam CT for Adaptive Radiotherapy: Assessment of Image Distortion, Auto-Contouring, and Dose Delivery Accuracy in the Presence of Periodic Subject Motion

Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania

Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...

Optimizing Vessel Wall Visualization Using a Novel Black-Blood CT Technique on Craniocervical CT Angiography

Authors: Xiaohu Li, Jianjun Shen, Guozhi Zhang, Sihua Zhong, Jingjie Zhou

Affiliation: United Imaging Healthcare

Abstract Preview: Purpose:
Visualization of carotid artery vessel wall on computed tomography angiography (CTA) imaging is challenging. This study aims to develop a novel post-processing technique, black-blood compu...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Quantification of Global Dosimetry Audit Performance: Assessing the Sensitivity and Specificity of Dosimetry Audits to Establish Reciprocity Among Different International Clinical Trials Credentialing Organizations

Authors: Fre'Etta Brooks, Catharine H Clark, Patricia Diez, Peter B. Greer, Hideaki Hirashima, Rebecca M. Howell, Mohammad Hussein, Stephen F. Kry, Joerg Lehmann, Jessica Lye, Mitsuhiro Nakamura, Christopher L. Nelson, Rushil Patel, Christine Peterson, Julianne M. Pollard-Larkin

Affiliation: Kyoto University, The University of Texas MD Anderson Cancer Center, Radiotherapy Trials Quality Assurance Group, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Medical Physics & Biomedical Engineering, University College London, Metrology for Medical Physics, National Physical Laboratory, Austin Health, University of Washington Medical Center, University of Newcastle

Abstract Preview: Purpose: To assess the consistency of end-to-end dosimetry audits currently used by different international clinical trial QA organizations with the goal of harmonizing audits and reducing audit overl...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...