Search Submissions 🔎

Results for "reference phantoms": 71 found

3D Image Quality Evaluation of a New CT Scanner Employing 3D Landmark Scans, Super Resolution Reconstruction, and Ag Beam Filtration

Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White

Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ

Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...

A Clarification on the Bandwidth Difference Method for MRI B0 Homogeneity Assessment

Authors: Christina Brunnquell, Daniel Vergara, Joseph Everett Wishart

Affiliation: University of Minnesota, University of Washington

Abstract Preview: Purpose: To propose and validate a correction to the bandwidth difference method presented in Task Group Report No. 325 for quantifying static magnetic field homogeneity (ΔB0).
Methods: A clarifica...

A Dosimetric Study of Small-Field Apertured Spot-Scanning Proton Stereotactic Radiosurgery for Pediatric Brain Tumors

Authors: Chin-Cheng Chen, Chia-Ho Hua, Christopher J. Kutyreff, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: A dosimetric study was conducted to determine the optimal field parameters for a commercially available small-field applicator (SFA) used in spot-scanning proton stereotactic radiosurgery, pa...

A Dynamic Reconstruction and Motion Estimation Framework for Cardiorespiratory Motion-Resolved Real-Time Volumetric MR Imaging (DREME-MR)

Authors: Jie Deng, Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Based on a 3D pre-treatment MRI scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a moti...

A Fast Low-Dose Method for Beam Blocker-Based CBCT Scatter Correction

Authors: Yidong Yang, Haolin Zhan

Affiliation: Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop a fast low-dose method for beam blocker-based CBCT scatter correction and evaluate image quality in phantom study.
Methods: The full number of scatter projections were collected...

A Refined Model of Reference Mesh-Type Female Breast Model Vasculature and Glandular Structures for Internal Circulating Lymphocyte Dosimetry

Authors: Wesley E. Bolch, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Lazaro Fuentes Alfonso, Shreya P. Pathak, Julia D. Withrow

Affiliation: University of Florida

Abstract Preview: Purpose: To develop tetrahedral mesh-based tissue models within the breasts of the International Commission on Radiological Protection (ICRP) adult female mesh-type reference computational phantom (AF...

A Setup and Workflow for Fully Automated Electromagnetic Tracking-Based Implant Reconstruction in Intraoperative Prostate HDR Brachytherapy

Authors: Ioannis Androulakis, Miranda E.M.C. Christianen, Jérémy Godart, Mischa Hoogeman, Inger-Karine K. Kolkman-Deurloo, Lorne Luthart, Remi A. Nout, Henrike Westerveld

Affiliation: Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
Despite the advantages of transrectal ultrasound-based treatment planning for HDR prostate cancer brachytherapy which allows on-line treatment delivery in the intraoperative setting, it is...

Analysis of Noise Power Spectra in MR Parallel Imaging

Authors: Sulaiman D. Aldoohan, Gerardo Garcia

Affiliation: University of Toledo Medical Center

Abstract Preview: Purpose: To evaluate the noise power spectra (NPS) of images acquired using parallel imaging with varying acceleration factors in 1-D and 3-D spaces and to compare the level of the power of the noise ...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

BEST IN PHYSICS MULTI-DISCIPLINARY: Motion-Resolved Dynamic CBCT Reconstruction Using Prior-Model-Free Spatiotemporal Gaussian Representation (PMF-STGR)

Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Cherenkov to Dose Trends with Small Field Beams

Authors: Jeremy Eric Hallett, Aubrey Parks, Brian W Pogue

Affiliation: University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Cherenkov imaging visualizes radiotherapy beams, assuming emission is proportional to deposited dose. However, attempts for Cherenkov as a quantitative dose estimation have been unsuccessful ...

Comparative Analysis of Soft Tissues and 3D Printing Materials Using Euclidean Distance for Linear Attenuation Coefficient

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Elsa Bifano Pimenta

Affiliation: University of SĂŁo Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study evaluates the similarity between the linear attenuation coefficients of soft tissues and 3D printing materials in diagnostic imaging range using the Euclidean distance approach.

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Cross-Calibration of CT Number to Electron and Physical Density: Feasibility of Using Diagnostic Scans for Treatment Planning

Authors: Afrouz Ataei, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Even though many patients undergo diagnostic CT scans prior to treatment, simulation CT scans are commonly required for treatment planning. This study evaluates whether prior diagnostic CT sc...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development and Evaluation of Fat Fraction Reference Materials for Magnetic Resonance Imaging

Authors: Hyo-Min Cho, Cheolpyo Hong, Changwoo Lee, Sunyoung Lee

Affiliation: Daegu Catholic University, Korea Research Institute of Standards and Science (KRISS), Korea Research Institute of Standards and Science

Abstract Preview: Purpose: With the increasing prevalence of metabolic syndrome, the importance of diagnosing obesity and fatty liver diseases has grown significantly. As a result, there is a rising demand for non-inva...

Development and Validation of a Principal Component Analysis Statistical Shape Pediatric/Adolescent Breast Model for Pre-CT Era Breast Dose Reconstruction in Late Effect Studies of Female Childhood Cancer Survivors

Authors: Gregory T. Armstrong, James E. Bates, Kristy K. Brock, Laurence Edward Court, Matt Ehrhardt, Danielle Friedman, Aashish C. Gupta, Donald Hancock, Rebecca M. Howell, Cindy Im, Tera S Jones, Choonsik Lee, Wendy Leisenring, Taylor Meyers, Lindsay Morton, Chaya Moskowitz, Joe Neglia, Vikki Nolan, Caleb O'Connor, Kevin C. Oeffinger, Constance A. Owens, Arnold C. Paulino, Chelsea C. Pinnix, Sander Roberti, Cecile Ronckers, Susan A. Smith, Kumar Srivastava, Lucie Turcotte

Affiliation: Department of Medicine, Duke University School of Medicine, Department of Epidemiology and Cancer Control, St. Jude Children’s Research Hospital, The University of Texas MD Anderson Cancer Center, Department of Oncology, St. Jude Children’s Research Hospital, Department of Pediatrics, Memorial Sloan Kettering Cancer Center, Division of Pediatric Epidemiology and Clinical Research, University of Minnesota, Division of Childhood Cancer Epidemiology, University Medicine at Johannes Gutenberg University Mainz, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Pediatrics, University of Minnesota, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Department of Biostatistics, St. Jude Children’s Research Hospital, Clinical Research Division, Fred Hutchinson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: To (1) develop and validate a novel anatomically realistic pediatric/adolescent population-based breast model, (2) incorporate model into an age-scalable female reference phantom, and (3) dem...

Development of a Whole-Body Blood Flow Framework Based on the Icrp Blood Phantom

Authors: Jung Han Nam, Wonmo Sung

Affiliation: Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract Preview: Purpose: This study aims to develop a whole-body blood flow framework based on the ICRP 145 standard vascular phantom to simulate the spatiotemporal trajectories of blood cells in the human vasculatur...

Dosimetric Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT Techniques: Analysis with Central and Peripheral Lung Tumors

Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav

Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute

Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...

Dosimetric Parameter Cross-Check Evaluations for Dedicated Biologically-Guided Radiotherapy Linac Using Two Water Phantom Systems

Authors: Nguyen Phuong Dang, Mason Hazlett, Lijun Ma, Yutaka Natsuaki, William T. Watkins, Zhengzheng Xu, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, Radiation Oncology, Keck School of Medicine of USC, RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: This is the first study reporting the beam dosimetric parameter cross-checks of Reflexion linac using different water phantom systems and detectors. The difference in measurements using diffe...

Dosinme: A 3D Visualization Platform for Internal Dosimetry and Radionuclide Behavior in Computational Human Phantoms

Authors: Lotem Buchbinder Shadur, Shaheen Dewji, Martin Graffigna, Alejandro Rafael Martinez, Emmanuel Mate-Kole, Antonio McClain, Samuel Taylor, Jeffrey Wang

Affiliation: Student, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: DosInMe is an internal dosimetry visualization tool developed by the Radiological Engineering, Detection, and Dosimetry Laboratory at Georgia Tech to assist researchers and professionals in v...

EBT4 Film Dosimetry and the Significance of the Œ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Electronic Brachytherapy Dosimetric Reference Datasets Using Model-Based Dose Calculation Algorithms

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Laval University, Princess Margaret Cancer Centre, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta

Abstract Preview: Purpose: Modelling electronic brachytherapy (eBT) sources is difficult because of the high-dose gradients and challenges associated with low-energy modelling. This study examines the accuracy of avail...

Emulating Human Perception of Low-Dose CT Image Quality Via Deep Generative Models

Authors: Jongduk Baek, Jooho Lee, Adam S. Wang

Affiliation: Stanford University, Yonsei University

Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Establishing a Protocol for Quality Assessment of Ultrasound Shear Wave Elastography (SWE) and Application to a Musculoskeletal (MSK) Task

Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...

Estimating Organ Dose of Standard Pediatric CT Protocols to Computational Phantoms through the Dukesim CT Simulator

Authors: Dean Darnell, Iyanna M Lewis, Francesco Ria, William Paul Segars

Affiliation: Duke University, Duke University Medical Physics Graduate Program, Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Duke University Medical Center

Abstract Preview: Purpose: To estimate radiation dose to pediatric patients during standard CT imaging of the chest and abdomen and determine how dose varies with patient age, height and weight and how measurements com...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: ClĂ­nica Iram, Clinica Alemana, Hospital ClĂ­nico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluation of Hypersight CBCT Scanning Techniques for Motion Management in Online Adaptive Radiotherapy: A Comparative Study of Slow, Fast, and Averaged Scans

Authors: Fan Liu, Adam C. Riegel, Yi-Fang Wang

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, Varian Medical Systems' latest CBCT technology, integrates rapid 6-second data acquisition with advanced iterative reconstruction, enabling precise real-time contouring and dose c...

Evaluation of Ion Chamber Performance and Suitability for Flash Proton Therapy Dosimetry

Authors: Seohyeon An, Yoonsun Chung, Seonghoon Jeong, Seongmoon Jung, Chae-Eon Kim, In Jung Kim, Sung Hun Kim, Se Byeong Lee, Sang-il Pak, Jong In Park

Affiliation: POHANG ACCELERATOR LABORATORY, Hanyang University, Korea Research Institute of Standards and Science (KRISS), Ilsan Paik Hospital, National Cancer Center, National Cancer Center Korea, Korea Research Institute of Standards and Science

Abstract Preview: Purpose: To evaluate the performance of three ion chambers—Advanced Markus (AMC), PinPoint, and Roos—under FLASH proton beam conditions and assess the response of the nozzle monitor chamber for their ...

Evaluation of MR Proton Density Fat Fraction (PDFF) for Bone Marrow Protection in RT

Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang

Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital

Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of Time Delays in a Surface-Guided Radiotherapy-Based Gating System Using Exactrac Dynamic and Truebeam Linear Accelerator

Authors: Hiroki Katayama, Hiroki Kawasaki, Motonori Kitaoka, Yosuke Takahashi, Takashi Tanii, Masato Tsuzuki

Affiliation: Kagawa University Hospital

Abstract Preview: Purpose:
Surface-guided radiotherapy (SGRT) with ExacTrac Dynamic (ETD) allows motion tracking and beam gating during treatment delivery. Accurate evaluation of beam-on and beam-off delays is essen...

Feasibility of 3D Printing for Fabricating Anthropomorphic Kidney Phantoms

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Wagner Henrique Marques, Raphael Morata, Victor H.F Oliveira

Affiliation: University of SĂŁo Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study investigates the feasibility of 3D printing materials in creating anthropomorphic kidney phantoms that accurately simulate the radiological properties of human tissues, for applica...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

Finding the Best Match of 4D-CT Phases to Delineate Volumes for Bgrt

Authors: Resat Aydin, Joseph Barbiere, Brett Lewis, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
Accurately compensating for respiratory-induced tumor motion is critical in BgRT, where precise delineation of volumes ensures effective dose delivery. We propose an integrated approach th...

Generation of Patient-Specific Phantom for Head & Neck Proton Therapy Based on Xcat

Authors: Cheng-En Hsieh, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu, An-Ci Yang

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose:
The aim of this study is to develop a framework of generating patient-specific phantom tailored for head and neck proton therapy. From these phantoms, digital reference objects based on th...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

High-Resolution Limited-Angle CBCT Image Reconstruction for Non-Coplanar Radiation Therapy Via Dual-Domain Ordered-Subset Neural Representation with Prior Embedding (DDOS-NeRP)

Authors: Yu Gao, Lei Xing, Siqi Ye

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) scans are often the only option for non-coplanar radiation therapy to prevent potential mechanical collisions. However, the consecutive angular occlusion of pr...

Hybrid Prior-Enhanced Deep Image Prior (HPEDIP) Image Reconstruction for Ultra-Short Scans

Authors: Renee Farrell, Jinkoo Kim, Xin Qian, Ziyu Shu, Zhaozheng Yin, Tiezhi Zhang

Affiliation: Stony Brook Medicine, Washington University in St. Louis, Stony Brook University, Stony Brook University Hospital

Abstract Preview: Purpose: Ultra-short CT scan allows fast imaging speed, dose reduction, and compact system design. We developed a deep image prior (DIP) based reconstruction method named Hybrid Prior-Enhanced Deep Im...

Icrp Mesh-Type Reference Computational Phantoms Representing Pregnant Women and Fetuses

Authors: Wesley E. Bolch, Chansoo Choi, Chan Hyeong Kim, Suhyeon Kim, Bangho Shin, Yeon Soo Yeom

Affiliation: Hanyang University, University of Florida, 2) Department of Radiation Convergence Engineering, Yonsei University

Abstract Preview: Purpose: Task Group 103 of International Commission on Radiological Protection (ICRP) recently released new-generation adult and pediatric mesh-type reference computational phantoms (MRCPs) via ICRP P...

Impact of Tissue Heterogeneity on Proton LET and RBE Distributions: A Monte Carlo Study

Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences

Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...

Implementing TG-191 for Robust Calibration of Scintillation Imaging As a Clinical dosimetry Tool

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...

Improvement of Spine Phantom for MR Imaging of the Spine

Authors: Richard Dortch, Thammathida Ketsiri, Zhiqiang Li, Shiv P. Srivastava

Affiliation: Barrow Neurological Institute, Dignity Health Cancer Institute, St. Joseph's Hospital & Medical Center

Abstract Preview: Purpose: Imaging the spinal cord post-surgery is challenging due to metal surgical implants, which induce signal loss and geometric distortions. Together, this hinders the visualization of the spinal ...

Investigation of Metallic Artefact Reduction Capabilities of Hypersight Enabled Platforms

Authors: Harald Keller, Iymad Mansour, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Monte Carlo Simulation of Dose Perturbations in HAM Applicator HDR Brachytherapy Treatments

Authors: Sam Beddar, Brett Bocian, David B. Flint, Benjamin Abraham Insley, Patrick James Jensen, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Reza Reiazi, Gabriel O. Sawakuchi

Affiliation: University of Miami, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Empyrean Medical Systems, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The Harrison-Anderson-Mick (HAM) applicator is an Ir-192 High-Dose-Rate (HDR) intraoperative radiotherapy device. It features a silicone body with embedded catheters that guide the Ir-192 sou...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

Novel Fast Cone-Beam CT for Adaptive Radiotherapy: Assessment of Image Distortion, Auto-Contouring, and Dose Delivery Accuracy in the Presence of Periodic Subject Motion

Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania

Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...

On the Sensitivity Evaluation of End-to-End Test in Radiotherapy

Authors: Yussuf A. Abdelal, Sebastien A. Gros, Luke Layman, Anil Sethi

Affiliation: Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago

Abstract Preview: Purpose:
End-to-end (E2E) test is a vital QA check of the overall radiotherapy process from simulation imaging to treatment delivery. Although clinical passing criteria are available, guidelines on...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Posterior-Mean Diffusion Model for Realistic PET Image Reconstruction

Authors: Osama R. Mawlawi, Yiran Sun

Affiliation: RICE University, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Conventional PET reconstruction methods often produce noisy images with artifacts due to data/model mismatches and inconsistencies. Recently, deep learning-based conditional denoising diffusi...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

Robustness of Jacobian-Based and HU Change-Based CT Ventilation Imaging to Respiratory Amplitude Variations: A Study Using a Custom Phantom with Respiratory Amplitude Control

Authors: Tatsuya Fujisaki, Hiraku Fuse, Shin Miyakawa, Hiroki Nosaka, Masato Takahashi, Kenji Yasue

Affiliation: Ibaraki Prefectural University of Health Sciences

Abstract Preview: Purpose: This study aimed to evaluate the robustness of Jacobian-based and HUchange-based CT ventilation imaging (CTVI) against respiratory amplitude variations using a custom-designed alveolar phanto...

S Values for a Monkey Computational Model for Internally Distributed Radiation Sources

Authors: Jae Won Jung, Daniel Lee

Affiliation: Thomas S. Wootton High School, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: Monkeys have played a key role in enhancing our understanding of the behavior of radioactive materials within living organisms in the field of nuclear medicine. However, detailed dosimetric d...

Signal-to-Noise Ratio Estimation from Polynomial Fitting of Acr MRI Phantom Images

Authors: Alex Lindgren-Ruby, Jeffrey M. Moirano, Joseph Everett Wishart

Affiliation: University of Washington

Abstract Preview: Purpose:
To evaluate polynomial fitting of signal intensity for signal-to-noise ratio (SNR) estimation from weekly QC ACR MRI phantom images and compare against other SNR estimation methods as well...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

The Unspoken Impact of Couch Sag on Breathing-Traces Collected during Patient Simulation

Authors: Giorgi Archuadze, William P. Donahue, David Kanchaveli, Shih-Chi Lin, Sebastian Meyer, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Breathing traces captured at simulations are often used for deep-inspiration breath-hold (DIBH) treatments. However, systematic drift can occur in the traces that is unrelated to the patients...

Toward Harmonized AI-Based Quantitative CT: A Voxel-Printed, Patient Specific Phantom for Cross-Platform Harmonization

Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...

Towards Arbitrary Phantom Patient Specific IMRT QA on Reflexion X1

Authors: Andrew Groll, Ayan Mitra, PhD, Manoj Narayanan, Sanchit Sharma, Ray Yang, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: To develop a versatile QA tool enabling dose recalculation of a patient’s plan sinogram redeployed onto arbitrary replacement phantom geometry, and extract computed dose along detector planes...

Validation and Benchmarking of Mirdct Software for Organ Dose Estimation in Routine CT Protocols

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...

Variance and Estimation of Patient Specific S-Values for I-131 Administration.

Authors: Jae Won Jung, Choonsik Lee, Jason C. Mace, Sergio Morato Rafet

Affiliation: East Carolina University, Carilion Clinic, National Cancer Institute

Abstract Preview: Purpose: Dosimetry for radionuclides used in nuclear medicine can be accurately calculated if sufficient data is available. However, in most cases crucial information cannot or will not be known a pri...

Variations in Radiation Isocenter Offsets from the Winston-Lutz Test Performed on Different Photon Energies

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: To quantity variations in Winston Lutz (WL) test results due to different energies used in SBRT, SRT or SRS.
Methods: A WL phantom with a 6.4 mm diameter center radio-opaque sphere is used...

“See” through Surface: Transforming Surface Imaging into a Real-Time Three-Dimensional Imaging Solution for Intra-Treatment Image Guidance

Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...