Authors: Hongyu An, Phillip Cuculich, H Michael Gach, Yao Hao, Trevor McKeown, Clifford Robinson, Yuhao Wang, Deshan Yang
Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Duke University, Department of Radiation Oncology, Duke University, Washington University in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis
Abstract Preview: Purpose: Cardiorespiratory motion management is crucial in stereotactic arrhythmia radiotherapy to define target margins and minimize cardiac toxicity. While respiratory 4DCT (r4DCT) images can infer ...
Authors: Hideaki Hirashima, Haruo Inokuchi, Nobutaka Mukumoto, Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao, Keiko Shibuya, Linna Zhang
Affiliation: Kyoto University, Osaka Metropolitan University
Abstract Preview: Purpose:
To transform the quality of 2D cine MR images acquired during online adaptive MR-guided radiotherapy (OA-MRgRT) by utilizing a conditional diffusion model to achieve image quality comparab...
Authors: Kristy K. Brock
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: N/A...
Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Samuel Richter, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: This study evaluates the necessity and potential benefits of online adaptive stereotactic body radiotherapy (SBRT) for prostate cancer using the ViewRay MR-Linac system. By leveraging real-ti...
Authors: Matthew J Ferris, Jason K Molitoris
Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland
Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...
Authors: Quan Chen, Xue Feng, Chunhui Han, Gaofeng Huang, Trevor Ketcherside, Yi Lao, Yun Rose Li, An Liu, Bo Liu, Kun Qing, William T. Watkins
Affiliation: Graduate Program in Bioengineering, University of California San Francisco-UC Berkeley, Department of Radiation Oncology, City of Hope National Medical Center, Mayo Clinic Arizona, Carina Medical LLC
Abstract Preview: Purpose: New treatment platforms such as Ethos (Varian Medical Systems) allow the introduction of multi-modal imaging into adaptive radiotherapy workflow to facilitate an up-to-date view of patients’ ...
Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute
Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...
Authors: Cem Dede, Clifton David Fuller, Renjie He, Laia Humbert Vidan, Stephen Y. Lai, Amy Moreno, Mohamed Naser, Kareem Abdul Wahid, Natalie A West
Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Head and neck cancers (HNC) treated with radiation therapy can result in radiation-induced bone injury. In CT, changes in radiodensity correlate to changes in bone integrity. Most studies use...
Authors: Yibin Ling, Qihui Lyu, Ke Sheng
Affiliation: University of California Berkeley, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
High Dose Rate (HDR) brachytherapy enables radiation to concentrate on the tumor by sending the high-dose-rate radioactive source directly to the treatment site. On the other hand, the sha...
Authors: Rex Carden, Carlos E. Cardenas, Ho-hsin Rita Chang, John B Fiveash, Heinzman A. Katherine, Yogesh Kumar, Gaurav Nitin Rathi, Richard A. Popple, Kayla Lewis Steed
Affiliation: University of Alabama at Birmingham
Abstract Preview: Purpose: Brain metastases (BMs) often require multiple radiotherapy (RT) courses as new lesions appear. Comparing follow-up imaging with prior RT plans is time-intensive. We developed an AI tool that ...
Authors: Abdusalam Abdukerim
Affiliation: Institute for Medical Imaging Technology, Ruijin Hospital
Abstract Preview: Purpose:
Coronary computed tomography angiography (CCTA) is the gold-standard non-invasive test for coronary artery disease (CAD), but iodine contrast agents (ICA) pose limitations in specific popu...
Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman
Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity
Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...
Authors: Sarah Burleson, Antonio L. Damato, Yabo Fu, Laura Happersett, Tianfang Li, Xiang Li, Himanshu Nagar, Pengpeng Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: An iodinated hydrogel perirectal spacer, injected between the prostate and rectum, reduces rectal high-dose exposure during prostate SBRT. We assessed the feasibility of tracking the spacer a...
Authors: Derek A. Fiedler, Nixon Gutierrez, Quyen L. Jones, Zejian Liu, Tatsiana Reynolds
Affiliation: Texas Oncology, Minnesota Oncology, US Oncology
Abstract Preview: Purpose: Optimize patient safety and treatment efficacy during radiation re-treatment planning. Provide a comprehensive comparison of the methods by focusing on their applicability, accuracy, and limi...
Authors: Neha Devi, Deon M. Dick
Affiliation: Jaeger Corporation
Abstract Preview: Purpose: To evaluate the impact of bladder volume variation on small bowel dose in prostate cancer patients with nodal involvement and assess the efficacy of a 'half-full bladder' guideline for minimi...
Authors: Christian Fiandra, Marco Fusella, Gianfranco Loi, Silvia Pesente, Lorenzo Placidi, Claudio Vecchi, Orlando Zaccaria, Stefania Zara
Affiliation: Abano Terme Hospital, University of Turin, Maggiore della Carità, Tecnologie Avanzate Srl, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Abstract Preview: Purpose: Deformable-image-registration (DIR) is essential in modern radiotherapy for adaptive RT, re-irradiation, and other clinical applications. Multimodal DIR is especially important in MRI-only wo...
Authors: Hacene Azizi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Mohamed Lamine Seghier
Affiliation: Khalifa University Biomedical Engineering & Biotechnology, Laboratory of dosing, analysis and characterization in high resolution, Ferhat Abbas Setif 1 University, Khalifa University Physics Department, Khalifa University
Abstract Preview: Purpose:
To ensure accurate alignment of cone-beam computed tomography (CBCT) and computed tomography (CT) images for image-guided radiotherapy, this study evaluates a foundation model guidance fra...
Authors: Cheng-En Hsieh, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu, An-Ci Yang
Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou
Abstract Preview: Purpose:
The aim of this study is to develop a framework of generating patient-specific phantom tailored for head and neck proton therapy. From these phantoms, digital reference objects based on th...
Authors: So Hyun Ahn, Chris Beltran, Byongsu Choi, Jeong Heon Kim, Jin Sung Kim, Bo Lu, Justin Chunjoo Park, Bongyong Song, Jun Tan
Affiliation: Mayo Clinic, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Ewha Medical Research Institute, Ewha Womans University College of Medicine, UC San Diego, Yonsei University College of Medicine
Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) is widely used in IGRT for patient positioning but suffers from low resolution and poor soft tissue contrast. Synthetic CT (sCT) generated from CBCT ad...
Authors: Ana Maria Barragan Montero, Damien Dasnoy, Sylvain Deffet, Valentine Dormal, Colin Gaban, Melanie Ghislaine, Valentin Hamaide, Guillaume Janssens, John A. Lee, Eliot Peeters, Danah Pross, Luciano Rivetti, Benjamin Roberfroid, Romain Schyns, Kevin Souris, Edmond S. Sterpin, Sophie Wuyckens
Affiliation: Ion Beam Applications SA, Hospital Riviera-Chablais, UCLouvain, Multitel, Université Catholique de Louvain, IBA, Faculty of Mathematics and Physics, University of Ljubljana, Universite Catholique de Louvain
Abstract Preview: Purpose: Treatment planning systems (TPSs) are essential for simulating and optimizing radiotherapy treatments. However, clinical TPSs are expensive software commercialized by private companies and of...
Authors: Yao Chen, Lesley A Jarvis, Allison Matous, Rongxiao Zhang
Affiliation: Dartmouth College, University of Missouri, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose: Precise patient positioning is critical in accelerated partial breast irradiation (aPBI) to ensure accurate dose delivery to the tumor bed while minimizing exposure to surrounding healthy tis...
Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu
Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health
Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...
Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu
Affiliation: Mayo Clinic
Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)
Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...
Authors: Tatsuya Fujisaki, Hiraku Fuse, Shin Miyakawa, Hiroki Nosaka, Masato Takahashi, Kenji Yasue
Affiliation: Ibaraki Prefectural University of Health Sciences
Abstract Preview: Purpose: This study aimed to evaluate the robustness of Jacobian-based and HUchange-based CT ventilation imaging (CTVI) against respiratory amplitude variations using a custom-designed alveolar phanto...
Authors: Jeremy S. Bredfeldt, Benito De Celis Alonso, Braian Adair Maldonado Luna, Kevin M. Moerman, Gerardo Uriel Perez Rojas, René Eduardo Rodríguez-Pérez, Kamal Singhrao
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Mechanical Engineering, University of Galway, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla
Abstract Preview: Purpose: Online adaptive radiotherapy replanning for single-isocenter bone cancer metastasis treatment reduces on-table treatment time and patient discomfort compared to the multi-isocenter standard-o...
Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang
Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University
Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...
Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.
Methods: CT and CBCT images from 65 abdominal pat...