A Fast Low-Dose Method for Beam Blocker-Based CBCT Scatter Correction

Authors: Yidong Yang, Haolin Zhan

Affiliation: Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop a fast low-dose method for beam blocker-based CBCT scatter correction and evaluate image quality in phantom study.
Methods: The full number of scatter projections were collected...

An Accelerated Scatter Estimation for Spectral CBCT Based on Linear Boltzmann Transport Equation

Authors: Zhiqiang Chen, Hewei Gao, Li Zhang, Guoxi Zhu

Affiliation: Tsinghua University

Abstract Preview: Purpose: Spectral cone-beam CT has better performance in material identification and quantitative analysis compared to single-energy cone-beam CT. However, X-ray scattering introduces significant scat...

Comparative Study between Sparse Primary Sampling Grid Scatter Correction and Low-Count Monte Carlo-Based Scatter Reduction with 3-D Richardson-Lucy Denoising

Authors: Alan Rui Li, Qihui Lyu, Dan Ruan, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
The Sparse Primary Sampling (SPS) grid was shown in a previous computational study to improve image quality by correcting scatter-induced effects and artifacts in Cone-beam Computed Tomogr...

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Design of Next Generation Hemispherical Brain PET System Aiming for 1mm Resolution

Authors: Go Akamatsu, Yuma Iwao, Kurumi Narita, Hideaki Tashima, Taiga Yamaya, Eiji Yoshida

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In brain positron emission tomography (PET), higher spatial resolution is better for visualizing detailed structures such as small nuclei and the layered structure of the cerebral cortex. The...

Development and Clinical Validation of a Tissue Maximum Ratio (TMR)-Based Monitor Units Second Check Script for Dynamic Conformal-Based Hyperarc Brain Radiosurgery Plans Via Scatter Correction Factors

Authors: Jacob Gooslin, Ellis Lee Johnson, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: HyperArc radiosurgery permits treatment of multiple brain lesions using a single-isocenter improving treatment planning efficiency and workflow. A key stereotactic planning aspect is an indep...

Dual-Domain Neural Network Cone-Beam CT Correction for Online Adaptive Proton Therapy

Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey

Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong

Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...

Investigation of a Novel Snout-Mounted Compton Camera System for Monitoring Dose Depth

Authors: Ananta Raj Chalise, Matthias K Gobbert, Hajar Moradmand, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, University of Maryland, Baltimore County, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: We are developing a novel Compton Camera (CC) system mounted orthogonally on the treatment nozzle for prompt gamma (PG) imaging-based proton range verification during treatment. This study in...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Monte Carlo Simulation of a Prototype Fluence Field Modulated Cone Beam CT System

Authors: Gregory J Bootsma, Tunok Mondol

Affiliation: University Health Network, Princess Margaret Cancer Center

Abstract Preview: Purpose:
To evaluate the impact of prototype fluence field modulation (FFM) cone-beam CT (CBCT) on dose reduction and image quality using Monte Carlo simulations. This study particularly looks at t...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Optimizing Dosimetry in Rpt Clinics: Tackling Initial Hurdles and Ensuring Image Accuracy.

Authors: Siju C. George, Alonso N. Gutierrez, Vivek Mishra, Ranjini P. Tolakanahalli

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute

Abstract Preview: Purpose: This presentation focuses on optimizing dosimetry in RPT clinics by tackling initial setup challenges and ensuring the accuracy of SPECT/CT imaging for dosimetry. It will address the qualific...

Synthetic Vs. Conventional Planar Imaging: Performance and Clinical Feasibility

Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman

Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University

Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...

Task-Specific Deep-Neural-Network Architecture Optimization for CBCT Scatter Correction

Authors: Hoyeon Lee

Affiliation: University of Hong Kong

Abstract Preview: Purpose: Deep-learning approaches are widely investigated for Cone-Beam CT (CBCT) scatter correction to improve the quality of the linear-accelerator mounted CBCT. This study aims to optimize the deep...

Using Multi-Peak Reconstructions for Dosimetry of Fast and Quantitative Lutetium-177 SPECT/CT

Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija

Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging

Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...