A Method for Automatic Working Angle Prediction during Intracranial Aneurysms Embolization

Authors: Tina Ehtiati, Grace Jianan Gang, Limei Ma, Oleg Shekhtman, Visish M. Srinivasan

Affiliation: Siemens Medical Solutions USA, Inc., University of Pennsylvania

Abstract Preview: Purpose: Saccular aneurysms are the most common type of intracranial aneurysm and are typically treated by endovascular embolization. The procedure requires approximately orthogonal fluoroscopy images...

A Novel Feature Selection Method for Survival Prediction of Head-and-Neck Following Radiation Therapy

Authors: Xiaoying Pan, X. Sharon Qi

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, School of Computer Science and technology,Xi'an University of Posts and Telecommunications

Abstract Preview: Purpose:
Survival prediction for cancer presents a substantial hurdle in personalized oncology, due to intricate, high-dimensional medical data. Our study introduces an innovative feature selection...

A Pilot Survey on Medical Physics Residency Education in External Beam Special Procedures

Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng

Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester

Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...

An Analytical Framework to Quantify the Effect Obstructing Anatomical Features in Intrafractional Spectral Imaging Using a Dual-Layer Kv Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory

Abstract Preview: Purpose:
Dual-layer kV imager (DLI) architecture enables the capability for single-shot dual-energy (DE) intrafraction imaging. As noise from individual DLI layers are primarily uncorrelated, simpl...

Automated Classification of Treatment Sites from Physician Consult Notes Using a Large Language Model

Authors: Klea Hoxha, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, UCLA Radiation Oncology

Abstract Preview: Purpose: Ambiguities in physician simulation orders lead to workflow disruptions during CT simulation. Often, information that could provide
helpful context to simulation therapists and planners is...

Beam Orientation Optimization in IMRT Using Sparse Mixed Integer Programming and Non-Convex IMRT Fluence Map Optimization

Authors: Yabo Fu, Yang Lei, Yu Lei, Haibo Lin, Ruirui Liu, Tian Liu, Kenneth Rosenzweig, Charles B. Simone, Shouyi Wei, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York Proton Center

Abstract Preview: Purpose: Beam orientation optimization (BOO) in intensity-modulated radiation therapy (IMRT) is traditionally a complex, non-convex problem tackled with heuristic methods. This study benchmarks global...

Characterization of a Novel Large-Sized Epid System from the Newly Released Ring Shape Radiation Therapy Halos Tx

Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang

Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment

Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...

Differential Hole-Size Lattice Patterns for Escalating SFRT Dose to Large, Deep-Seated, and Unresectable Masses

Authors: Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumor’s center, surrounded by smaller diameter spheres. W...

Dynamic Winston-Lutz Testing for FFF Beams

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...

Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Feasibility Study of Single Gantry Angle Proton Minibeam Lattice Radiotherapy

Authors: Anthony Hong Cheol Lim, Rayyan L Mahmood, Alexander Stanforth, Chris C. Wang, Mingyao Zhu

Affiliation: Georgia Institute of Technology, Emory University

Abstract Preview: Purpose: The purpose of this project is to test the feasibility of proton minibeam lattice radiotherapy within an existing clinical setting.
Methods:
The TOPAS code is used to model a scenario i...

Film-Based Method for Accurate Radiation Isocenter Determination in Linear Accelerators Using 3D Starshot

Authors: Robert A. Corns, Mohammad Kanber

Affiliation: East Carolina University, East Carolina University Brody School of Medicine

Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...

Gaze Angle Selection in Proton Therapy for Ocular Tumors with Machine Learning

Authors: Ling Chen, Alexei V. Trofimov, Yi Wang, Dufan Wu

Affiliation: Massachusetts General Hospital, MGH

Abstract Preview: Purpose:
Selecting gaze angles of the eye is an important part of set-up of proton therapy for ocular tumors, ensuring that the treatment beam could irradiate the tumor while maximally sparing impo...

Improving Output Stability with Angular Correction Factor on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...

Investigating the Dosimetric Benefits of Enhanced Solid Angle Accessibility in a Self-Shielded Radiosurgery System

Authors: Peter Jermain, Ying Niu, Abdul Rashid, Yuan Yuan, Mohammad Zarenia

Affiliation: Medstar Georgetown University Hospital, MedStar Georgetown University Hospital, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose: ZAP-X is a self-shielded radiosurgery system that utilizes a linac-based isocentric technique and a compact gyroscopic gantry design. While it provides a large solid angle for beam orientatio...

Monte Carlo Simulation of a Prototype Fluence Field Modulated Cone Beam CT System

Authors: Gregory J Bootsma, Tunok Mondol

Affiliation: University Health Network, Princess Margaret Cancer Center

Abstract Preview: Purpose:
To evaluate the impact of prototype fluence field modulation (FFM) cone-beam CT (CBCT) on dose reduction and image quality using Monte Carlo simulations. This study particularly looks at t...

Multi-Center Evaluation of an AI Beam Angle Prediction Model for Liver Treatments Using Pencil Beam Scanning Proton Therapy

Authors: Christopher Ackerman, Chang Chang, Yan-Cheng Huang, Robert Kaderka, Che Lin, Hsin-Chih Lo, Iain MacEwan, Yi-Chin Tu, James Urbanic

Affiliation: University of California San DIego, Taiwan AI Labs, National Taiwan University, California Protons Cancer Therapy Center, University of Miami, Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: To investigate the performance of an existing AI beam angle prediction model on external patient datasets for liver proton treatments. The AI model was trained on datasets exclusively from on...

Rapid Reconstruction of Extremely Accelerated Liver 4D MRI Via Chained Iterative Refinement

Authors: Mary Feng, Yi Lao, Hui Lin, Hengjie Liu, Xin Miao, Michael Ohliger

Affiliation: University of California, Los Angeles, Department of Radiation Oncology, University of California San Francisco, Department of Radiation Oncology, City of Hope National Medical Center, University of California San Francisco, Siemens Medical Solutions USA Inc.

Abstract Preview: Purpose: 4D MRI with high spatiotemporal resolution is vital to characterize the tumor/tumor motion for liver radiotherapy. However, high-quality 4D MRI requires an impractically long scanning time fo...

Real Time Monte Carlo Dose Calculation for Clinical Cyberknife Radiation Therapy Based on Deep Learning Diffusion Model

Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...