Search Submissions 🔎

Results for "setup errors": 42 found

A Hybrid 4π-Proton Arc Robust Optimization

Authors: Wenhua Cao, Xianjin Dai, PhD, Hadis Moazami Goudarzi, Gino Lim, Miaolan Xie, Lei Xing, Lewei Zhao

Affiliation: University of Chicago Booth School of Business, Department of Radiation Oncology, Stanford University, Department of Industrial Engineering, University of Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) delivers a continuous dose of radiation during gantry rotation. 4π is a non-coplanar technique used for advanced proton therapy delivery. This work proposes a hybrid ...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

A Setup and Workflow for Fully Automated Electromagnetic Tracking-Based Implant Reconstruction in Intraoperative Prostate HDR Brachytherapy

Authors: Ioannis Androulakis, Miranda E.M.C. Christianen, Jérémy Godart, Mischa Hoogeman, Inger-Karine K. Kolkman-Deurloo, Lorne Luthart, Remi A. Nout, Henrike Westerveld

Affiliation: Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
Despite the advantages of transrectal ultrasound-based treatment planning for HDR prostate cancer brachytherapy which allows on-line treatment delivery in the intraoperative setting, it is...

Automated Tool for Radiotherapy Initial Patient Setup: A Robust Approach Based on Vertebral Identification

Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute

Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...

BEST IN PHYSICS MULTI-DISCIPLINARY: Motion-Resolved Dynamic CBCT Reconstruction Using Prior-Model-Free Spatiotemporal Gaussian Representation (PMF-STGR)

Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...

Could Synthetic CTs Simulating Patient Anatomical Changes Help Improve the Robustness of Head-and-Neck Proton Plans?

Authors: Nrusingh C. Biswal, Matthew J Ferris, Michael J. MacFarlane, Jason K Molitoris, Byong Yong Yi, Mark J. Zakhary

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland

Abstract Preview: Purpose: Proton head-and-neck treatment plans often struggle to maintain plan quality over the course of treatment due to tumor response, weight-loss, and setup variability. Plan robustness to these c...

Data-Driven Forward Projector for Optimization of the Proton Stopping Power Calibration in Treatment Planning Based on Sparse Proton Radiographies

Authors: Hector Andrade-Loarca, Ines Butz, Chiara Gianoli, Prof. Gitta Kutyniok, Jianfei Li, Katia Parodi, Prof. Vincenzo Patera, Angelo Schiavi, Prof. Ozan Öktem

Affiliation: Sapienza University of Rome, Department of Mathematics, Royal Institute of Technology, School of Computation, Information and Technology, Technische Universitaet Muenchen, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Mathematics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München

Abstract Preview: Purpose: To explore and demonstrate the feasibility of accurate and fast prediction of the water equivalent thickness (WET) distribution of tissue traversed by a proton imaging pencil beam, aiming at ...

Deep Learning-Based Fast CBCT Imaging with Orthogonal X-Ray Projections for Gynecological Cancer Radiotherapy

Authors: Beth Bradshaw Ghavidel, Chih-Wei Chang, Yuan Gao, Priyanka Kapoor, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Jill Remick, Justin R. Roper, Zhen Tian, Xiaofeng Yang

Affiliation: Whinship Cancer Institute, Emory University, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Current cone-beam computed tomography (CBCT) typically requires no less than 200 degrees of angular projections, which prolongs scanning time and increases radiation exposure. To address thes...

Detector Physics-Incorporated Diffusion Denoising Models for Digital Breast Tomosynthesis with Dual-Layer Flat Panel Detectors

Authors: Alexander Bookbinder, Matthew Tivnan, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Massachusetts General Hospital

Abstract Preview: Purpose: To investigate and benchmark a system-adaptive diffusion-based digital breast tomosynthesis (DBT) denoising model for a direct-indirect dual-layer flat panel detector (DI-DLFPD) with a k-edge...

Development of a Fast Quality Assurance Software Tool for Helical Online Adaptive Radiation Therapy

Authors: Guang-Pei Chen, Mi Huang, Haidy G. Nasief, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Recently, kV imaging has been integrated into the Accuray Radixact platform, facilitating online adaptive and scan-plan-treat workflows with helical delivery in the near future. In order to s...

Development of a Quantitative Surface Mapping Analysis Framework Involving a Robust Mask Removal Algorithm for Improved Objective Patient Setup Assessment in Head and Neck Intensity Modulated Proton Therapy

Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Michael H. Shang, Stephen Shang, Timothy R Williams

Affiliation: South Florida Proton Therapy Institute, SFPRF, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose:
Daily image guidance for head and neck intensity-modulated proton therapy (IMPT) presents significant challenges due to large target volumes and anatomical changes. Geometric deviations al...

Developments of a Low-Cost Multi-Target Winston-Lutz Phantom and Software for SRS Linac Machines

Authors: Nellie Brovold, Wenbo Gu, Huan Amanda Liu, Lin Ma

Affiliation: University of Pennsylvania, Mayo Clinic

Abstract Preview: Purpose: To develop a low-cost comprehensive QA phantom and software for single-iso multi-target SRS Linac machines. This phantom can perform 1) Winston-Lutz QA test for on-axis and off-axis targets, ...

Direct-to-Unit Dose Calculations for Stereotactic Radiosurgery on a C-Arm Linac with Modern on-Board Imaging Solutions

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...

Dosimetric Effect of Patient Positioning Errors in Dual-Isocenter VMAT for Bilateral Breast Cancer Treatment: A Quantitative Assessment

Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the dosimetric effects of patient positioning errors, including setup inaccuracies and yaw deviations, on dual-isocenter volumetric modulated arc therapy (VMAT) plans for...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Dosimetric Impact on Patient Roll/Yaw Change for Whole Breast 3D Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of target coverage and organ at risk (OARs) sparing for whole breast patient setup roll/yaw change in 3D-conformal radiotherapy.
Methods: 8 whole breast cases...

Efficient Robustness Optimization in Intensity Modulated Proton Therapy for Head and Neck Cancer Via Visual State Space Attention Generative Adversarial Networks (VSSA-GAN)

Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang

Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...

Enhancing Urethral Visualization for Prostate SBRT Using Post-Void T2-Weighted Imaging on a Low-Field 0.35T MR-Linac System

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Accurate delineation of the urethra is critical for optimizing tumor control and minimizing urethral toxicity in prostate stereotactic body radiation therapy (SBRT). The purpose of this study...

Evaluating Stent-Induced Dose Perturbations in Intravascular Brachytherapy with EBT4 Films

Authors: Yijian Cao, Jenghwa Chang, Nicholas Coupey, Lyu Huang, Jessica Jung

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
The Synergy bioabsorbable polymer (BP) stent, made of Platinum Chromium Alloy, is widely utilized in treating coronary artery disease. This study investigates dose perturbations caused by ...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

FMEA for Direct to Unit Adaptive Radiotherapy

Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert

Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis

Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...

Failure Mode and Effects Analysis (FMEA) on Use of Surface Guided Imaging

Authors: Victoria Noelle Bry, Tamara Egan, Eric C. Ford, Angelia Landers, Juergen Meyer

Affiliation: Fred Hutch Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) can improve patient safety, however, its complex integration may expose processes to increased risk of error. This work identifies potential failures f...

Fast 3D Scintillation Dosimetry Using Single View Deep Learning Reconstruction

Authors: Louis Archambault, Nicolas Drouin, Alexis Horik, Simon Thibault

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de Physique, de Génie Physique et D'optique, et Centre d'optique, photonique et laser, Université Laval

Abstract Preview: Purpose: To develop a novel type of real-time 3D dosimeter for the quality assurance of linear accelerators used in external beam radiotherapy.
Methods: An experimental setup was constructed using ...

First in-Vivo Proton Radiography Experiments for an Image-Guided Small Animal Irradiation Platform with a TimePix3-Based Detector Setup

Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl

Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam

Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.

Methods:...

Hypersight® Offline Adaptive Workflow

Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC

Abstract Preview: Purpose: The goal of the HyperSight® offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...

Iguard: A Fully Unsupervised Image-Guidance Anomaly Recognition and Detection Framework in CBCT-Guided Radiotherapy.

Authors: James M. Lamb, Dishane Chand Luximon, Jack Neylon, Rachel Petragallo, Moritz Ritter, Timothy Ritter

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, ETH Zurich, VCU Health System, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: Anomalies in cone beam computed tomography (CBCT) radiotherapy image guidance can signal treatment deviations. Repetitive review of setup image registrations by humans is inefficient, prone t...

Impact of Patient Setup Errors on the MR Linac-Based SBRT Treatment for Prostate Cancer

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: In radiation therapy, patient setup errors have been a primary concern impacting dose delivery accuracy. A robust treatment plan is essential to mitigate these errors. This study aimed to eva...

Improving Operational Efficiency in Head and Neck Proton Therapy through Adaptation Analysis

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey

Affiliation: Thompson Proton Center

Abstract Preview: Purpose: Proton therapy plans can be highly sensitive to both anatomical changes and positional errors, making the acquisition of Quality Assurance CT (QACT) images a routine clinical practice during ...

Investigation into the Robustness of Spine Stereotactic Body Radiotherapy Plans to Patient Setup Errors

Authors: Yukio Fujita, Syoma Ide, Fumiki Ito, Kei Ito, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki, Riku Watanabe

Affiliation: Komazawa University Graduate School, Komazawa University, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital

Abstract Preview: Purpose: Spine stereotactic body radiotherapy (SBRT) demands high precision due to the target's proximity to the spinal cord and steep dose gradients, which complicate treatment planning. Consequently...

Investigations on Intensity-Modulated Proton Therapy Robust-Optimization Strategies and Their Dosimetric Effects on Head and Neck Cancers

Authors: Shen Fu, Zhangmin LI, Zuofeng LI, Yuanshui Zheng

Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center

Abstract Preview: Purpose: To investigate the influence of different robustness optimization strategies and parameters in proton therapy plans for head and neck tumors on target coverage and OAR (organ at risk) sparing...

Mask-Less Adaptable Headrest for Head-and-Neck Radiotherapy

Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater

Affiliation: Saint Louis University

Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patients’ setups. MAHR complements current image-guidance...

Mid-Range Planning for Efficient and Robust Proton Arc Therapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Objective Verification of Mechanical and Radiation Isocenters Independent of Setup

Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.

Abstract Preview: Purpose: The novel machine quality assurance (QA) device nüFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...

QA Your QA:3 Steps to Ensure a Robust QA Review Workflow.

Authors: Shahid B. Awan, Harold Li, Aba Lippuner

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: QA review is a necessary component of QA management but is often pushed aside owing to time constraints and overreliance on vendor solutions. At our multicenter institution, we designed a 3-s...

Quantitative 3D Surface Mapping of Cherenkov Images for Real-Time Beam Deviation Detection in Radiotherapy

Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone

Affiliation: Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Cherenkov images are two-dimensional projections of the surface light emissions, and lack spatial information about the radiotherapy beam delivery. We implement the first fusion of Cherenkov ...

Rapid CBCT Imaging with Ultra-Sparse X-Ray Projections for Head & Neck Cancer Radiotherapy

Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...

Reproducibility of a Unique Prone Head and Neck Setup Evaluated with In Vivo Epid Dosimetry System

Authors: Salim Balik, Eric Chang, Kristine Garcia, Andrew Islas, Lijun Ma, Zhilei Liu Shen, Elizabeth Zhang-Velten

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: NRG protocols recommend simulating and treating head and neck (HN) cancer patients in a supine position for optimal setup reproducibility. However, certain patients cannot tolerate the supine...

Robustness Enhancement for VMAT-TBI Planning and Treatment Delivery

Authors: Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Edward L. Clouser, Yi Rong, Jun Tan, Jennifer Yan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
To identify planning techniques that consistently result in robust VMAT-TBI plans that allow for larger patient setup errors.
Methods:
Conventional planning method often results in p...

Standardized Immobilization and Setup Procedure Improves Accuracy of Multi-Time Point SPECT/CT Image Registration for Radiopharmaceutical Therapy (RPT) Dosimetry

Authors: Bryan Bednarz, Laura Bennett, Abby E. Besemer, Tyler J Bradshaw, Steve Y Cho, John M. Floberg, Joseph Grudzinski, Elissa Khoudary, Michael J. Lawless

Affiliation: Department of Radiology, University of Wisconsin, University of Wisconsin-Madison Department of Medical Physics, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Voximetry, Inc, University of Pennsylvania, Department of Radiology, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: To assess the impact of using a standardized immobilization setup for multi-time-point SPECT/CT imaging on radiopharmaceutical therapy (RPT) dosimetry image registration.

Methods: Ten ...

Uncertainty Analysis of Hyperarc VMAT Plans for Stereotactic Radiosurgery Patients with Multiple Brain Metastases

Authors: Shifeng Chen, Yannick P. Poirier, Huijun Xu, Byong Yong Yi, Baoshe Zhang, Hong Zhang, Jinghao Zhou

Affiliation: University of Maryland School of Medicine, University of Maryland Shore Regional Cancer Center, Vanderbilt University Medical Center, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center

Abstract Preview: Purpose: To thoroughly assess the resilience of HyperArc VMAT plans for multiple brain metastases (MBT) in relation to (i) high-definition MLC leaf positional inaccuracies and (ii) patient rotational ...

Validation of an Ivim Tool for Liver Hypoxia Assessment for an Online Adaptive MR-Linac System

Authors: Jean-Pierre Bissonnette, Catherine Coolens, Laura Dawson, Ryan A Kuhn, Michael Maddalena, Teo Stanescu

Affiliation: Princess Margaret Hospital, The Princess Margaret Cancer Centre - UHN, University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To investigate the generation and reproducibility of 3D hypoxia maps in liver hepatocellular carcinoma (HCC) patients using data derived from an Intravoxel Incoherent Motion (IVIM) MR sequenc...