Search Submissions 🔎

Results for "sids 100": 31 found

4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A Knowledge-Based Approach for High-Quality Accelerated Partial Breast Irradiation Using Stereotactic Body Radiotherapy

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Allison Dalton, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: External-beam Accelerated Partial Breast Irradiation (APBI) using stereotactic-body radiotherapy (SBRT) is increasingly adopted as an alternative to whole-breast radiation, offering targeted ...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Surface-Conforming Flexible Collimator for Improving Electron Radiotherapy

Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz

Affiliation: UT Health San Antonio

Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...

An Advanced Automated Pipeline for Brain Tumor Segmentation on MRI Images in Gamma Knife Radiotherapy

Authors: Zachery Colbert, Matthew Foote, Michael Huo, Mark Pinkham, Prabhakar Ramachandran, Mihir Shanker

Affiliation: Radiation Oncology, Princess Alexandra Hospital, Ipswich Road, Princess Alexandra Hospital

Abstract Preview: Purpose: The study aimed to develop and implement deep learning-based autosegmentation models for the autosegmentation of four key tumor types: brain metastasis, pituitary adenoma, vestibular schwanno...

An Alpha Irradiation System for Radiobiological Studies with Versatile Dose Rate Control

Authors: Harsh Arya, Yan Chang, Yujie Chi, Varghese Anto Chirayath, Joshua Rajan, Pan Zui

Affiliation: University of Texas at Arlington, Department of Physics, University of Texas at Arlington

Abstract Preview: Purpose: In targeted alpha therapy (TAT), absorbed dose rates can vary significantly spatially and temporally, impacting therapeutic efficacy as well as carcinogenic potential. This study reports the ...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Construction and Application Study of a Deep Learning-Based Iscout-Guided Precision Radiotherapy Positioning Error Prediction Model for Breast Cancer

Authors: Fangfen Dong, Jiaming Li, Xiaobo Li, Weipei Wang, Zhixin Wang, Bing Wu, Benhua Xu, Yong Yang, Yifa Zhao

Affiliation: Department of Radiation Oncology, Fujian Medical University Union Hospital/Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematologi, Zhangpu County Hospital, School of Medical Imaging, Fujian Medical University

Abstract Preview: Purpose: To explore the construction and clinical application value of a deep learning-based positioning error prediction model, providing a reference for optimizing iSCOUT system-guided precision rad...

Decoupling Cardiorespiratory Motion of Cardiac Substructures Via 5D-MRI for Radiotherapy

Authors: Carri K. Glide-Hurst, Thomas M Grist, Kevin M. Johnson, Prashant Nagpal, Tarun Naren, Chase Ruff, Oliver Wieben, Jiwei Zhao

Affiliation: Department of Biostatistics and Medical Informatics, University of Wisconsin - Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison

Abstract Preview: Purpose: Cardiotoxicity is a devastating side effect for thoracic radiotherapy (RT). Currently, standard RT imaging is insufficient to decouple cardiorespiratory motion, limiting substructure-specific...

Deep Learning Aided Oropharyngeal Cancer Autoplanning

Authors: Mark Bowers, Gabriel Carrizo, Jimmy Caudell, Vladimir Feygelman, Kevin Greco, Christian Hahn, Jihye Koo, Kujtim Latifi, Fredrik Lofman, Jacopo Parvizi, Muqeem Qayyum, Caleb Sawyer

Affiliation: RaySearch Laboratories, Moffitt Cancer Center

Abstract Preview: Purpose: Head and neck (H&N) radiotherapy planning is complex, with multiple competing objectives. We endeavored to improve efficiency of planning by developing a deep learning (DL) model trained to p...

Development and Clinical Validation of an Analytical Approach for 3D Positron Emitter Distribution Prediction in Carbon Ion Therapy

Authors: Julia Bauer, Tianxue Du, Katia Parodi, Marco Pinto, Thomas Tessonnier

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose:
Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing irradiation-induced PE...

Dosimetric Assessment of Multicriteria Optimization for Accelerated Partial Breast Irradiation (APBI)

Authors: Alyssa Gadsby, William J. Godwin, Jennifer L. Harper, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: Multi-Criteria Optimization (MCO) theoretically allows for increased dose control during optimization. This study is the first to compare standard optimization (SO) and MCO for accelerated pa...

Dosimetric Impact on Patient Roll/Yaw Change for Whole Breast 3D Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of target coverage and organ at risk (OARs) sparing for whole breast patient setup roll/yaw change in 3D-conformal radiotherapy.
Methods: 8 whole breast cases...

Effects of Plan Optimization Techniques on Relative Biological Effective Dose in a Thin Intracranial Target Volume

Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center

Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Evaluation of Lead Glasses Efficiency in Reducing Eye Radiation Exposure during Angiography Using Optically Stimulated Luminescence Dosimeters

Authors: Yu-Ying Lin, Yu Chen Shen

Affiliation: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou

Abstract Preview: Purpose: This study evaluates the protective efficiency of lead glasses against radiation exposure to the eyes during angiography using optically stimulated luminescence dosimeters (OSLDs).
Methods...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Multi-Sid Optimization for 4 Pi Robotic Radiotherapy

Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...

Normal Tissue Dosimetry during Intra-Cavitary HDR Brachytherapy

Authors: Palanisamy Karunanithi, Karthikeyan Perumal, Siva Subramanian Vadivel

Affiliation: Dr. Kamakshi Memorial Hospital

Abstract Preview: Purpose:
Recent advancements in high dose-rate (HDR) brachytherapy include the image guidance, new applicators, and dose calculation algorithms. Brachytherapy has steep dose gradient, hence relativ...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Optimizing the Design for a Directional Brachytherapy Source

Authors: Akire Trestrail

Affiliation: University of Wisconsin

Abstract Preview: Purpose: To investigate the feasibility of using 125I as a HDR directional brachytherapy source.
Methods: Monte Carlo (MC) simulations were performed using the EGSnrc software toolkit. Dose rate di...

Physics-Informed Neural Network for In Vivo Dosimetry during Proton Therapy Using Protoacoustic Tomography

Authors: Kristina Bjegovic, Yong Chen, Gilberto Gonzalez, Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu

Affiliation: University of Maryland School of Medicine, University of California, Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is becoming an increasingly popular choice for cancer treatment due to its precision, reduced side effects, and effectiveness. While dosimetry is fundamental to the success of ...

Quantum-Inspired Genetic Optimization Tailored for Patient Scheduling in Radiation Oncology

Authors: Arezoo Modiri, Robabeh Rahimi, Akira SaiToh, Amit Sawant

Affiliation: Maryland University Baltimore, University of Maryland, University of Maryland in Baltimore, Department of Computer and Information Sciences, Sojo University

Abstract Preview: Purpose: It has been a longstanding challenge to optimize the daily schedule of radiation treatment rooms toward minimum patient wait times, efficient use of clinical staff and reduced running cost of...

Towards Penile Small Vessel Imaging with Ferumoxytol-Enhanced MRI

Authors: Darren Fang, Amar Kishan, Justin McWilliams, Dan Ruan, Xiaodong Zhong

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Department of Radiological Sciences, University of California, Los Angeles

Abstract Preview: Purpose: Prostate radiotherapy can malform penile vasculature, contributing to erectile dysfunction and compromising quality of life. To detect, quantify, and preferably avoid such occurrences, this p...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...

Using Machine Learning to Predict Esophagitis Risk in Lung Cancer Radiotherapy Based on Clinical and Dosimetric Factors

Authors: Ibtisam Almajnooni, Siyong Kim, Nathaniel Miller, Elisabeth Weiss, Lulin Yuan

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: Radiation-induced esophagitis (RE) is a common concern in lung cancer IMRT. Recent studies have indicated that the risk of radiation side effects varies greatly with patients’ baseline clinic...

Validation of 3D Pseudo-Dose Map Reconstructed from Multi-View Cherenkov Images in Total Skin Electron Therapy

Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison

Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...