Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega
Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...
Authors: Jonathan Dowell, Grace Francis, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Iridesce Solutions, Inc.
Abstract Preview: Purpose: A novel radiation therapy quality assurance (RT QA) device has been designed, constructed and tested. The nüFilmTM machine QA system provides a method for collecting light, mechanical and rad...
Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan
Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle
Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...
Authors: Ivan L. Cordrey, Dharmin D. Desai, Ellis Lee Johnson
Affiliation: Cumberland Medical Center - Cancer Center, University of Kentucky, Varian Advanced Oncology Solutions
Abstract Preview: Purpose: HyperArc (HA) is known to produce a high quality SRS plan. Adding Surface Area Informed Optimization (SAIO) to HA has been shown to improve plan quality metrics R50% and the Conformality Inde...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...
Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Jacob Gooslin, Ellis Lee Johnson, Damodar Pokhrel
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: HyperArc radiosurgery permits treatment of multiple brain lesions using a single-isocenter improving treatment planning efficiency and workflow. A key stereotactic planning aspect is an indep...
Authors: Nellie Brovold, Wenbo Gu, Huan Amanda Liu, Lin Ma
Affiliation: University of Pennsylvania, Mayo Clinic
Abstract Preview: Purpose: To develop a low-cost comprehensive QA phantom and software for single-iso multi-target SRS Linac machines. This phantom can perform 1) Winston-Lutz QA test for on-axis and off-axis targets, ...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...
Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue
Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...
Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao
Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine
Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...
Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang
Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...
Authors: Jessica Fagerstrom, Juliana Ama Kplorfia, Abigail N.M. Quaye, Mercy T Schandorf, Bishwambhar Sengupta, Peniel T Twum, Afua A. Yorke
Affiliation: University of Ghana Medical Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Medical Equipment and Ancillary Services, Girls Excellence Movement, Global Communities
Abstract Preview: Purpose: To empower and promote diversity in Science, Technology, Engineering, and Mathematics (STEM), an educational presentation and hands-on session were organized to raise awareness of STEM career...
Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng
Affiliation: UC San Diego, UCSD, University of California San Diego
Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...
Authors: Maria de la Luz De Ornelas, Yunze Yang
Affiliation: University of Miami
Abstract Preview: Purpose:
An extended Winston-Lutz test (EWL), also known as off-axis Winston-Lutz, was performed to assess the linear accelerator’s (linac) deviations at isocenter and five off-iso targets. The imp...
Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman
Affiliation: Salem Health Cancer Center, Salem Health
Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...
Authors: Rex A. Cardan, Carlos E. Cardenas, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li, Rodney J. Sullivan, Natalie N. Viscariello, Christopher Willey
Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham
Abstract Preview: Purpose: vBrain radiosurgery toxicity-rate is estimated via clinically-relevant isodose volume (IDV) thresholds according to HyTEC (e.g., V12Gy≤10cc). HyperArcTM (HA) automated planning allows accurat...
Authors: William E Burrell, Philip F. Durham, Anne N Hubbard, Yohan Akeakamai Walter, Hsinshun Terry Wu
Affiliation: Willis Knighton Cancer Center
Abstract Preview: Purpose: Linear accelerator (LINAC)-based single-isocenter, multi-target (SIMT) treatment has streamlined the stereotactic radiosurgery (SRS) workflow. However, off-isocenter treatment carries multipl...
Authors: Anupama Chundury, Hyejoo Kang, John C. Roeske, Iris A. Rusu
Affiliation: Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago
Abstract Preview: Purpose: To quantify the dosimetric impact of six degrees of freedom (6DoF) intrafractional errors on gross tumor volume (GTV) and planning target volumes (PTV) for single-isocenter multi-target stere...
Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu
Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...
Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang
Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...
Authors: Molokotima Kekana, Dennis S. Mackin, Stephen W. Peterson, Jerimy C. Polf
Affiliation: Department of Physics, University of Cape Town, M3D, Inc, The University of Texas MD Anderson Cancer Center, Houston
Abstract Preview: Purpose: To study the imaging characteristics of a prototype prompt gamma (PG) imaging system consisting of multiple rotating Compton cameras (CC).
Methods: The prototype CC imaging system is c...
Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold
Affiliation: Scripps Cancer Center
Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...
Authors: Anthony J. Doemer, Yimei Huang, Benjamin Movsas, Ellen Park, Mira Shah, Salim Siddiqui, Karen C. Snyder, Kundan S Thind, Bo Zhao
Affiliation: Henry Ford Health
Abstract Preview: Purpose: The 6 degrees-of-freedom (6-DoF) robotic couch is considered essential for linac-based stereotactic radiosurgery (SRS), particularly for irregularly shaped targets adjacent to critical organs...
Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang
Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center
Abstract Preview: Purpose: Using mixed fractionation schemes is a common technique in treating CNS lesions. This article describes an innovative plan-and-split approach for more efficient planning on the ZAP-X and thus...
Authors: Colton Baley, Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz
Affiliation: UT Health San Antonio, Texas Oncology, University of Texas HSC San Antonio
Abstract Preview: Purpose: To evaluate the accuracy of off-axis winston lutz (WLT) for linac based stereotactic radiosurgery (SRS) treatments using in-house phantom.
Methods: Traditional WLT that uses cone and s...
Authors: Mark W. Geurts, Bridget Ann Melke
Affiliation: Aspirus Health
Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...
Authors: Weiliang Du
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Winston-Lutz (WL) tests are often used to localize the radiation isocenter of a linac. The selection of gantry and collimator angles can affect the accuracy of the resulting isocenter. The ef...
Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu
Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company
Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...
Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din
Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University
Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...
Authors: John Ginn, Zhuoyun Huang, Yongbok Kim, Ke Lu, Chunhao Wang, Yibo Xie, Zhenyu Yang, Jingtong Zhao
Affiliation: Duke University, Duke Kunshan University
Abstract Preview: Purpose: This study aims to develop and validate a machine learning model for predicting V60%, a critical dosimetric metric in LINAC-based Single-Isocenter-Multiple-Targets (SIMT) stereotactic radiosu...
Authors: Albert Admasu, Kayla Alfonso, Maria de la Luz De Ornelas, Nesrin Dogan, Eric Mellon, Yunze Yang
Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Rotational uncertainties in single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) HyperArc treatments can cause additional target displacement, potentially degrading overall pl...
Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...
Authors: Jeremy S. Bredfeldt, Benito De Celis Alonso, Braian Adair Maldonado Luna, Kevin M. Moerman, Gerardo Uriel Perez Rojas, René Eduardo Rodríguez-Pérez, Kamal Singhrao
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Mechanical Engineering, University of Galway, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla
Abstract Preview: Purpose: Online adaptive radiotherapy replanning for single-isocenter bone cancer metastasis treatment reduces on-table treatment time and patient discomfort compared to the multi-isocenter standard-o...
Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West
Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma
Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...
Authors: Zhaohui Han, Piotr Zygmanski
Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: Real-time motion tracking/gating are oftentimes limited to a single sagittal plane on many magnetic resonance linear accelerators (MR-Linac). Out-of-plane motion is therefore difficult to det...
Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao
Affiliation: Varian AOS @Epic Care, UC Berkeley
Abstract Preview: Purpose: To quantity variations in Winston Lutz (WL) test results due to different energies used in SBRT, SRT or SRS.
Methods: A WL phantom with a 6.4 mm diameter center radio-opaque sphere is used...