Authors: Arash Bedayat, Jason Bradfield, Minsong Cao, Robert K Chin, Huiming Dong, J Paul Finn, Fei Han, Justin Hayase, Shu-Fu Shih, Xiaodong Zhong
Affiliation: Cardiac Electrophysiology, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Siemens Healthineers
Abstract Preview: Purpose: Cardiac SBRT is a promising treatment for ventricular tachycardia (VT). Success depends on accurate target delineation, for which 2D narrowband late gadolinium-enhanced (LGE) MRI offers valua...
Authors: Christopher J. Mart, Inna V. McGowin
Affiliation: Medical University of South Carolina
Abstract Preview: Purpose: Electron treatments are prone to setup variations and uncertainties due to absence of imaging or surface guided alignment. Patient setup relies on daily marking and visual verification. A 3D-...
Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng
Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester
Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...
Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz
Affiliation: UT Health San Antonio
Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...
Authors: Kostas Danniidis, Agelos Kratimenos, Yufu Wang, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: This study aims to develop software and algorithms utilizing artificial intelligence (AI) to seamlessly create 3D patient postures during Total Skin Electron Therapy (TSET). The resulting mes...
Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...
Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...
Authors: Julien Bancheri, Chau Giang Bui, Christopher M Lund, Morgan J Maher, Jamiel Nasser, Amy Parent, Monica Serban, Jan P. Seuntjens, Jason Z Yuan
Affiliation: University of Toronto, Medical Physics Unit, McGill University, Princess Margaret Cancer Centre, Princess Margaret Cancer Centre & University of Toronto
Abstract Preview: Purpose: Proton therapy (PT) has demonstrated greater precision and superior healthy tissue sparing compared to photon radiotherapy for various sites; however, PT systems are expensive, which limits g...
Authors: Ryan Clark, Anthony Magliari, Luis Felipe Oliveira E Silva, Yang Sheng, Jason R Vickress, Qingrong Jackie Wu, Giulianne Rivelli Rodrigues Zaratim
Affiliation: Verspeeten Family Cancer Center, Office of Medical Affairs, Varian, A Siemens Healthineers Company, Confiar Radioterapia, Duke University Medical Center
Abstract Preview: Purpose: Develop a toolset to replace several of the tedious steps required to manually generate 3D breast treatment plans using static gantry forward planned tangent beams.
Methods: Eclipse Sc...
Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price
Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center
Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...
Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura
Affiliation: University of Massachusetts Chan Medical School
Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...
Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao
Affiliation: The George Washington University, The George Washington University Cancer Center
Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...
Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak
Affiliation: Christiana Care
Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...
Authors: Baozhu Lu, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: Cherenkov intensity can be quantitatively correlated to surface dose but need certain corrections for accurate dose measurements. This study aims to investigate the impact of incident beam an...
Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine
Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...
Authors: Md. Jobairul Islam
Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre
Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...
Authors: Dylan Richeson, Dorin A. Todor
Affiliation: Inova Schar Cancer Institute, Virginia Commonwealth University
Abstract Preview: Purpose: High dose-rate (HDR) brachytherapy is prone to errors that can lead to incorrect dose delivery and potential medical events. One common issue is applicator length discrepancies, either due to...
Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng
Affiliation: New York Proton Center, Scarsdale High School
Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...
Authors: Darren Kaplan, Chenguang Liu, Mark Pankuch
Affiliation: Northwestern Medicine Proton Center
Abstract Preview: Purpose: This study evaluates the hypothesis that surface-guided radiation therapy for the breast or chest wall using proton PBS provides comparable target coverage and OARs sparing to x-ray-based IGR...
Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson
Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Laval University, Princess Margaret Cancer Centre, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta
Abstract Preview: Purpose: Modelling electronic brachytherapy (eBT) sources is difficult because of the high-dose gradients and challenges associated with low-energy modelling. This study examines the accuracy of avail...
Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez
Affiliation: University of Miami
Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...
Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng
Affiliation: UC San Diego, UCSD, University of California San Diego
Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...
Authors: Damien C. Mathew, Brandon Hai Nguyen, Satwik Pani, Yoichi Watanabe
Affiliation: Minnespolis Radiation Oncology, Department of Radiation Oncology, University of Minnesota Medical School, Washington University
Abstract Preview: Purpose: To formulate a computational algorithm to quantify the tumor movement from the motion data of landmarks on the brain surface. To estimate the magnitude of tumor movement when the head makes a...
Authors: Shifeng Chen, Mariana Guerrero, Michael J. MacFarlane, Huijun Xu, Baoshe Zhang, Jinghao Zhou
Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center
Abstract Preview: Purpose: The clinical value of surface-guided radiotherapy (SGRT) in prone breast cancer setups is much less established than in supine setups. This study explores SGRT's potential for prone breast pa...
Authors: Yunzhi Ma, Ling Zhuang
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...
Authors: Veng Jean Heng, Jan P. Seuntjens, Timothy C. Zhu, Yifeng Zhu
Affiliation: Department of Radiation Oncology, Stanford University, Princess Margaret Cancer Centre & University of Toronto, University of Pennsylvania
Abstract Preview: Purpose: We have developed a GPU-accelerated Monte Carlo (MC) simulation to determine the cumulative dose distribution of patients undergoing Total Skin Electron Therapy (TSET) using the Stanford tech...
Authors: Mahya Ahmadzadeh, Nagarajan Kandasamy, Keyur Shah, Gregory C. Sharp, Santhosh Vadivel, John MacLaren Walsh
Affiliation: Electrical and Computer Engineering Department, Massachusetts General Hospital, Emory University, Drexel University
Abstract Preview: Purpose: In image-guided radiotherapy (IGRT), cone beam CTs (CBCTs) suffer from distortions that degrade registration with planning CTs. While CycleGANs can generate synthetic CTs (sCTs) from CBCTs, e...
Authors: Seungryong Cho, Donghyeok Choi, Joonil Hwang, Byung-Hee Kang, Jin Sung Kim, Eungman Lee, Younghee Park
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, KAIST, Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Ewha Womans University of Medicine
Abstract Preview: Purpose: Radiation therapy (RT) is critical for cancer treatment, but changes in tumor size and shape during therapy challenge precise dose delivery. Adaptive radiation therapy (ART) addresses these v...
Authors: Karyn A Goodman, Yang Lei, Tian Liu, Pretesh Patel, Jing Wang, Kaida Yang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: This study aims to improve organ-at-risk (OAR) segmentation in pancreatic cancer stereotactic body radiotherapy (SBRT) by integrating clinical guidelines into deep learning workflows. We use ...
Authors: Hassan Bagher-Ebadian, Ahmed I Ghanem, Joshua P. Kim, Chengyin Li, Rafi Ibn Sultan, Kundan S Thind, Dongxiao Zhu
Affiliation: Wayne State University, Department of Radiation Oncology, Henry Ford Health-Cancer, Detroit, MI and Alexandria Department of Clinical Oncology, Faculty of Medicine, Alexandria University, Henry Ford Health
Abstract Preview: Purpose: Accurate segmentation of the Left Anterior Descending (LAD) artery in free-breathing 3D treatment planning CT is crucial for radiotherapy but remains challenging due to its small size, comple...
Authors: Zhongping Chen, Yuchen Song, Leshan Sun, Liangzhong Xiang, Yifei Xu
Affiliation: University of California, Irvine, University of California Irvine
Abstract Preview: Purpose: Electroacoustic tomography (EAT) monitors the distribution of electrical energy in tissues by detecting acoustics signals induced by electrical pulses during irreversible electroporation (IRE...
Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang
Affiliation: Cleveland Clinic
Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.
Methods: Two VMAT partial breast plans (3000 cGy in 5...
Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...
Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...
Authors: Baozhu Lu, Hongjing Sun, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: This study aims to validate the feasibility of using Cherenkov imaging for surface dose distribution measurement during Total Skin Electron Therapy (TSET) by developing a perspective-correcte...
Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas
Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis
Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...
Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison
Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...