Search Submissions 🔎

Results for "skin surface": 37 found

3D Wideband Late Gadolinium-Enhanced MRI for Radiotherapy of Ventricular Tachycardia: A Preliminary Study in Healthy Participants and Patient

Authors: Arash Bedayat, Jason Bradfield, Minsong Cao, Robert K Chin, Huiming Dong, J Paul Finn, Fei Han, Justin Hayase, Shu-Fu Shih, Xiaodong Zhong

Affiliation: Cardiac Electrophysiology, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Siemens Healthineers

Abstract Preview: Purpose: Cardiac SBRT is a promising treatment for ventricular tachycardia (VT). Success depends on accurate target delineation, for which 2D narrowband late gadolinium-enhanced (LGE) MRI offers valua...

A Novel 3D Printed Template for Electron Treatments to Aid Patient Positioning and Targeting.

Authors: Christopher J. Mart, Inna V. McGowin

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: Electron treatments are prone to setup variations and uncertainties due to absence of imaging or surface guided alignment. Patient setup relies on daily marking and visual verification. A 3D-...

A Pilot Survey on Medical Physics Residency Education in External Beam Special Procedures

Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng

Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester

Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...

A Surface-Conforming Flexible Collimator for Improving Electron Radiotherapy

Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz

Affiliation: UT Health San Antonio

Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...

AI-Assisted Algorithm to Generate Patient Postures for Tset Dose Evaluation

Authors: Kostas Danniidis, Agelos Kratimenos, Yufu Wang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to develop software and algorithms utilizing artificial intelligence (AI) to seamlessly create 3D patient postures during Total Skin Electron Therapy (TSET). The resulting mes...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

Automated Quantitative Method for Source Position Calculation in Annual Quality Assurance of High Dose Rate Brachytherapy Gynecological Applicators

Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...

Beam Characteristics of a Proposed Dielectric Wall Proton Accelerator Design

Authors: Julien Bancheri, Chau Giang Bui, Christopher M Lund, Morgan J Maher, Jamiel Nasser, Amy Parent, Monica Serban, Jan P. Seuntjens, Jason Z Yuan

Affiliation: University of Toronto, Medical Physics Unit, McGill University, Princess Margaret Cancer Centre, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: Proton therapy (PT) has demonstrated greater precision and superior healthy tissue sparing compared to photon radiotherapy for various sites; however, PT systems are expensive, which limits g...

Breastplan-Helper: Publicly Shared Source Scripting Toolset to Assist in 3D Breast Planning

Authors: Ryan Clark, Anthony Magliari, Luis Felipe Oliveira E Silva, Yang Sheng, Jason R Vickress, Qingrong Jackie Wu, Giulianne Rivelli Rodrigues Zaratim

Affiliation: Verspeeten Family Cancer Center, Office of Medical Affairs, Varian, A Siemens Healthineers Company, Confiar Radioterapia, Duke University Medical Center

Abstract Preview: Purpose: Develop a toolset to replace several of the tedious steps required to manually generate 3D breast treatment plans using static gantry forward planned tangent beams.

Methods: Eclipse Sc...

Can We Use Smaller Margin for the Planned Target Volume with Adaptive Radiotherapy?

Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center

Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Confidence in a Tattoo-Less Transition

Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak

Affiliation: Christiana Care

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...

Correcting for the Cherenkov-to-Dose Conversion for Tset Patients Using Monte Carlo Simulations

Authors: Baozhu Lu, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: Cherenkov intensity can be quantitatively correlated to surface dose but need certain corrections for accurate dose measurements. This study aims to investigate the impact of incident beam an...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Development and Validation of Patient-Specific 3D-Printed Electron Applicators for Precision Radiotherapy

Authors: Md. Jobairul Islam

Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre

Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...

Dosimetric Impact of Catheter Length Changes in HDR Brachytherapy for Accelerated Partial Breast Irradiation

Authors: Dylan Richeson, Dorin A. Todor

Affiliation: Inova Schar Cancer Institute, Virginia Commonwealth University

Abstract Preview: Purpose: High dose-rate (HDR) brachytherapy is prone to errors that can lead to incorrect dose delivery and potential medical events. One common issue is applicator length discrepancies, either due to...

Dosimetric Validation and Algorithmic Limitations of Pencil Beam Scanning Proton Therapy for Thin Chest-Wall Treatments

Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng

Affiliation: New York Proton Center, Scarsdale High School

Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...

Dosimetry Comparison of Surface-Guided and Orthogonal X-Ray Film-Based Setups for Proton Pencil-Beam Scanning in Breast Cancer Treatment

Authors: Darren Kaplan, Chenguang Liu, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center

Abstract Preview: Purpose: This study evaluates the hypothesis that surface-guided radiation therapy for the breast or chest wall using proton PBS provides comparable target coverage and OARs sparing to x-ray-based IGR...

Electronic Brachytherapy Dosimetric Reference Datasets Using Model-Based Dose Calculation Algorithms

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Laval University, Princess Margaret Cancer Centre, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta

Abstract Preview: Purpose: Modelling electronic brachytherapy (eBT) sources is difficult because of the high-dose gradients and challenges associated with low-energy modelling. This study examines the accuracy of avail...

Enhanced Surface Dose Accuracy in Proton Treatment Planning: Optimizing External Volume HU Thresholding.

Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez

Affiliation: University of Miami

Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Estimation of Brain Tumor’s Intra-Fraction Movement during Radiosurgery Using Fiducial Markers on the Skin Surface – a Simulation Study

Authors: Damien C. Mathew, Brandon Hai Nguyen, Satwik Pani, Yoichi Watanabe

Affiliation: Minnespolis Radiation Oncology, Department of Radiation Oncology, University of Minnesota Medical School, Washington University

Abstract Preview: Purpose: To formulate a computational algorithm to quantify the tumor movement from the motion data of landmarks on the brain surface. To estimate the magnitude of tumor movement when the head makes a...

Evaluating the Role of Surface-Guided Radiotherapy in Prone Breast Cancer Treatment

Authors: Shifeng Chen, Mariana Guerrero, Michael J. MacFarlane, Huijun Xu, Baoshe Zhang, Jinghao Zhou

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center

Abstract Preview: Purpose: The clinical value of surface-guided radiotherapy (SGRT) in prone breast cancer setups is much less established than in supine setups. This study explores SGRT's potential for prone breast pa...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

GPU Accelerated Monte Carlo Simulation for Tset Dose Calculation

Authors: Veng Jean Heng, Jan P. Seuntjens, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Princess Margaret Cancer Centre & University of Toronto, University of Pennsylvania

Abstract Preview: Purpose: We have developed a GPU-accelerated Monte Carlo (MC) simulation to determine the cumulative dose distribution of patients undergoing Total Skin Electron Therapy (TSET) using the Stanford tech...

Improving Adversarial Approaches to Synthetic CT Image Generation with Skin Surface Masks

Authors: Mahya Ahmadzadeh, Nagarajan Kandasamy, Keyur Shah, Gregory C. Sharp, Santhosh Vadivel, John MacLaren Walsh

Affiliation: Electrical and Computer Engineering Department, Massachusetts General Hospital, Emory University, Drexel University

Abstract Preview: Purpose: In image-guided radiotherapy (IGRT), cone beam CTs (CBCTs) suffer from distortions that degrade registration with planning CTs. While CycleGANs can generate synthetic CTs (sCTs) from CBCTs, e...

Improving Segmentation Precision in Prostate Cancer Adaptive Radiotherapy with the Intentional Deep Overfit Learning (IDOL) Approach

Authors: Seungryong Cho, Donghyeok Choi, Joonil Hwang, Byung-Hee Kang, Jin Sung Kim, Eungman Lee, Younghee Park

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, KAIST, Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Ewha Womans University of Medicine

Abstract Preview: Purpose: Radiation therapy (RT) is critical for cancer treatment, but changes in tumor size and shape during therapy challenge precise dose delivery. Adaptive radiation therapy (ART) addresses these v...

Integrating Clinical Knowledge Via Llms for Precise Organ-at-Risk Segmentation in Pancreatic Cancer SBRT

Authors: Karyn A Goodman, Yang Lei, Tian Liu, Pretesh Patel, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study aims to improve organ-at-risk (OAR) segmentation in pancreatic cancer stereotactic body radiotherapy (SBRT) by integrating clinical guidelines into deep learning workflows. We use ...

NA-Unetr: A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Authors: Hassan Bagher-Ebadian, Ahmed I Ghanem, Joshua P. Kim, Chengyin Li, Rafi Ibn Sultan, Kundan S Thind, Dongxiao Zhu

Affiliation: Wayne State University, Department of Radiation Oncology, Henry Ford Health-Cancer, Detroit, MI and Alexandria Department of Clinical Oncology, Faculty of Medicine, Alexandria University, Henry Ford Health

Abstract Preview: Purpose: Accurate segmentation of the Left Anterior Descending (LAD) artery in free-breathing 3D treatment planning CT is crucial for radiotherapy but remains challenging due to its small size, comple...

Non-Contact Electroacoustic Imaging Monitoring Electroporation Therapy

Authors: Zhongping Chen, Yuchen Song, Leshan Sun, Liangzhong Xiang, Yifei Xu

Affiliation: University of California, Irvine, University of California Irvine

Abstract Preview: Purpose: Electroacoustic tomography (EAT) monitors the distribution of electrical energy in tissues by detecting acoustics signals induced by electrical pulses during irreversible electroporation (IRE...

Quantification of Wet Towel As Bolus on Skin Dose for VMAT Partial Breast Irradiation

Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang

Affiliation: Cleveland Clinic

Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.

Methods: Two VMAT partial breast plans (3000 cGy in 5...

Reproducibility of Target Position during Surface-Guided Breath-Hold Adaptive SBRT of Liver Cancer

Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Surface Dose Distribution Analysis Using Cherenkov Imaging for Total Skin Electron Therapy (TSET) with Scintillator and Osld Validation

Authors: Baozhu Lu, Hongjing Sun, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to validate the feasibility of using Cherenkov imaging for surface dose distribution measurement during Total Skin Electron Therapy (TSET) by developing a perspective-correcte...

Utilizing All Acquired Images from Fluoroscopically-Guided Interventions: Test Application with Event-By-Event Patient Dosimetry Calculations

Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas

Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...

Validation of 3D Pseudo-Dose Map Reconstructed from Multi-View Cherenkov Images in Total Skin Electron Therapy

Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison

Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...