Search Submissions ๐Ÿ”Ž

Results for "slides scanned": 10 found

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

AI-Based Registration-Free 3T T2-Weighted MRI Synthesis Using Truefisp MRI Acquired on a 0.35T MR-Linac System

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Cynthia Fu-Yu Chuang, Yu Gao, Dimitre Hristov, Lianli Liu, Lawrie Skinner, Lei Xing

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose:
MR-guided radiation therapy has introduced a significant leap in cancer treatment by allowing adaptive treatment. The low-field MR-guided system predominantly uses the TrueFISP sequence, w...

Comparison of Clinical Virtual Unenhanced and True Unenhanced Images on a Prototype Deep Silicon Photon-Counting Detector CT

Authors: Meghan Lubner, Krista McClure, Aria M. Salyapongse, Timothy P. Szczykutowicz, Giuseppe Toia, Ming Yan, Zhye Yin, Meghan Yue

Affiliation: GE HealthCare, Departments of Radiology and Medical Physics, University Wisconsin-Madison, GE Healthcare, University of Wisconsin-Madison, UW-Madison, University of Wisconsin Madison, Department of Radiology

Abstract Preview: Purpose: To evaluate virtual unenhanced (VUE) and true unenhanced (TUE) human subject images on a prototype deep silicon photon-counting detector (PCD) CT with prototype algorithms.
Methods: 5 subj...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

Ensuring Consistency in Digital Pathology: Medical Physics Approaches to Comparison of Scanner Contrast and Chromaticity

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Medical physicists have traditionally supported radiation-based medicine, but their expertise can translate to other image-based fields including pathology. As pathology transitions to digita...

Ensuring Consistency in Digital Pathology: Medical Physics Approaches to Comparison of Scanner Sharpness and Artifact Severity

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Medical physicists traditionally support radiation-based medicine, but their expertise is translatable to image-based fields like pathology. As pathology transitions to digital practices, phy...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Iodine Quantification on a Prototype Deep Silicon Photon-Counting Versus Dual-Energy Energy-Integrating Detector CT

Authors: Meghan Lubner, Aria M. Salyapongse, Teva Shapiro, Scott D. Slavic, Timothy P. Szczykutowicz, Giuseppe Toia, Zhye Yin

Affiliation: GE HealthCare, Departments of Radiology and Medical Physics, University Wisconsin-Madison, GE Healthcare, University of Wisconsin-Madison, University of Wisconsin - Madison, UW-Madison, University of Wisconsin Madison, Department of Radiology

Abstract Preview: Purpose:
To compare iodine quantification on a prototype deep silicon photon-counting detector (PCD) CT and conventional clinical energy-integrating (EID) dual-energy (DE) CT.
Methods:
A phan...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jรคkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...