A Motion Tracking Quality Assurance Platform for the Leksell Gamma Knife Hdmm System

Authors: Tsuicheng D. Chiu, Strahinja Stojadinovic, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: Design and develop an automated verification and validation platform for the Elekta Leksell Gamma Knife (GK) Icon/Esprit High-Definition Motion Management (HDMM) system.

Methods: The H...

A Practical Experimental Software Validation Method for Voxel-Based Personalised Dosimetry in Radiopharmaceutical Therapy

Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal

Affiliation: University Hospital Southampton

Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...

A Simplified, Rigorous Procedure for Ultrasound Quality Assurance

Authors: Paul L. Carson, Sander Dekker, Stephen Z Pinter, Megan K. Russ

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Michigan, Cablon Medical B.V., Univ of Michigan, Dept. of Radiology

Abstract Preview: Purpose:
To promote a simplified, inexpensive, but rigorous set of ultrasound QA tests and to evaluate their potential using a Randomly-placed very Hypoechoic Sphere Phantom (RHSP) in comparison to...

An Automated Approach to Monitoring Clinical Protocols Against a Master Protocol

Authors: Jeremy Christophel, Zhihua Qi

Affiliation: Henry Ford Health

Abstract Preview: Purpose: To demonstrate a method to compare DICOM metadata from clinical scanners with institutional protocols as validation that clinical use matches the master protocol.
Methods: DICOM metadata i...

Automatic 4D Lung PET-CT Segmentation Using Hybrid Deep Neural Network

Authors: Hongyi Jiang, Fang-Fang Yin

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...

Automatic Specific Absorption Rate (SAR) Prediction for Hyperthermia Treatment Planning (HTP) Using Deep Learning Method

Authors: Yankun Lang, Lei Ren, Dario B. Rodrigues

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose:
HTP of microwave (MW) phased-array systems determine MW antenna settings to maximize energy absorption (SAR in W/kg) in tumor. Conventional HTP algorithms calculate SAR based on electromag...

Brachyplancheck: An Independent Monte Carlo Dose Calculation Tool for Brachytherapy Using Egs_Brachy

Authors: Amy Tien Yee Chang, Chi Wai Cheung, Tin Lok Chiu, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study introduces BrachyPlanCheck, an independent Monte Carlo (MC)-based dose calculation tool for 192Ir brachytherapy retrospective study or algorithm commissioning.
Methods: BrachyPl...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Clinical Validation of AI-Driven Segmentation Model for Pediatric Craniospinal Irradiation: Marked Reduction in Contouring Time and Enhanced Workflow Efficiency

Authors: Alexander Choi, William Ross Green, Christine Hill-Kayser, Gary D. Kao, Michael LaRiviere, Rafe A. McBeth, Steven Philbrook

Affiliation: Department of Radiation Oncology, University of Pennsylvania

Abstract Preview: Purpose: To validate the potential of clinical deployment of an in-house AI-driven auto-segmentation tool for pediatric craniospinal irradiation (CSI) in proton therapy, with goals of reducing manual ...

Contrast-Free Enhancement of Coronary Artery Stenosis: Synthetic Ccta from Non-Contrast CT Using Diffusion Model

Authors: Abdusalam Abdukerim

Affiliation: Institute for Medical Imaging Technology, Ruijin Hospital

Abstract Preview: Purpose:
Coronary computed tomography angiography (CCTA) is the gold-standard non-invasive test for coronary artery disease (CAD), but iodine contrast agents (ICA) pose limitations in specific popu...

Design and Construction of a Geometrical and Head Phantom with Internal Carotid Inserts for Flow Simulation in Image-Derived Input Function with 3T and 7T MR-Brainpet Insert Studies.

Authors: Dirk Grunwald, Hans Herzog, Hidehiro Iida, N. Jon Shah, Usman Khalid, Manfred Lennartz, Philipp Lohmann, Ceren Memis, Tobias Meurer, Claudia Regio Brambilla, Jürgen Scheins, Lutz Tellmann, Christoph W. Lerche, Martin Wiesmann, Karl Ziemons

Affiliation: FH Aachen University of Applied Sciences, Department of Chemistry and Biotechnology, Clinic for Diagnostic and Interventional Neuroradiology, Uniklinik Aachen,, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH,, Central Institute for Engineering, Electronics and Analytics (ZEA-1), Forschungszentrum, Turku PET Center, Institute of Biomedicine, Faculty of Medicine, University of Turku,

Abstract Preview: Purpose: Quantitative brain studies with positron emission tomography (PET) often require an arterial input function (AIF), which traditionally requires arterial cannulation. However, this is invasive...

Diffusion-Based PET Image Enhancement in Bgrt

Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie

Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The RefleXion® X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...

Evaluating Tumor Shrinkage Using Fractionated Radiotherapy: A Mixed Finite Element Method (FEM) for Free Boundary Problem

Authors: Xianjin Dai, PhD, Xiang Wan, Lei Xing, Qiuyun Xu, Lewei Zhao, Zeyu Zhou

Affiliation: Department of Radiation Oncology, Stanford University, Carl Zeiss X-ray Microscopy, Department of Mathematics and Statistics, Loyola University Chicago, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: The purpose of this study is to examine and quantify tumor shrinkage over time in response to fractionated radiotherapy. We seek to establish a predictive model that can provide a systematic ...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

G4BraggReflection: Pioneering Wave-Particle Simulations for Convergent Radiotherapy and Beyond

Authors: Dirk A Bartkoski, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour

Affiliation: The University of Texas MD Anderson Cancer Center, Convergent-RnR

Abstract Preview: Purpose:
To develop and validate G4BraggReflection, a novel physics process within Geant4, designed to incorporate diffraction properties resulting in Bragg reflection into Monte Carlo simulations....

Micro-Ultrasound Guided Focal Prostate Radiotherapy: Development and Testing of a Novel Device.

Authors: Kevin Barker, David Jeffrey Contella, Chandima Edirisinghe, Aaron Fenster, Douglas A Hoover, Elizabeth Huynh

Affiliation: Robarts Research Institute, University of Western Ontario, London Health Sciences Center, Department of Radiation Oncology, London Health Sciences Centre

Abstract Preview: Purpose: We aim to develop a system that integrates micro-ultrasound into focal prostate cancer radiotherapy. This requires developing a mechatronic stepper capable of performing motorized rotation of...

Novel 915 MHz Annular Phased Array Applicator for Hyperthermia Treatment of Brain Lesions

Authors: Jason Ellsworth, Mark Mishra, Jason K Molitoris, Lei Ren, Dario B. Rodrigues, Paul Turner, Graeme Woodworth

Affiliation: University of Maryland School of Medicine, Department of Neurosurgery, University of Maryland School of Medicine, University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Pyrexar Medical

Abstract Preview: Purpose: Hyperthermia therapy (HT) involves increasing tumor temperatures to 40-44°C and is a potent radio- and chemosensitizer for treating solid tumors. Current clinical strategies to heat deep-seat...

Reliable Markerless Lung Tumor Tracking with Built-in Patient-Specific Quality Assurance

Authors: Weixing Cai, Laura I. Cervino, Qiyong Fan, Yabo Fu, Tianfang Li, Xiang Li, Jean M. Moran, Hai Pham, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: AAPM Task Group Report 273 emphasizes the importance of rigorous validation to ensure the generalizability and robustness of machine learning-based clinical tools before their implementation ...

Validation and Benchmarking of Mirdct Software for Organ Dose Estimation in Routine CT Protocols

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...

Validation of Synthetic CT-Based Online Monitoring for Adaptive Proton Therapy

Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...