Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma
Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences
Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...
Authors: Ming Su, Yuenan Nancy Wang
Affiliation: Northeastern University, Hartford Healthcare
Abstract Preview: Purpose: High Z elements such as lead are often used to protect critical structures in clinical radiotherapy. Nanoparticles have different properties than bulk materials. We proposed a polymer matrix ...
Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health
Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...
Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC
Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...
Authors: Izabella L. Barreto, Aroon Pressram
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: Our clinical dual energy CT (DECT) head protocol reconstructs iodine-suppressed virtual non-contrast (VNC) images using the vendor-recommended slope for material discrimination. However, this...
Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser
Affiliation: Christiana Care
Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...
Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...
Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos
Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen
Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...
Authors: Paul Boisseau, Eric S. Diffenderfer, Andrew Friberg, Wenbo Gu, Matthew Nichols, Kan Ota, Xiaokun Teng, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou
Affiliation: Department of Radiation Oncology, University of Pennsylvania, Pyramid Technical Consultants, Inc., University of Pennsylvania
Abstract Preview: Purpose: Traditional quality assurance procedures for proton pencil beam energies involve water tank setups or multiple solid water phantoms and are time-consuming. This study demonstrates that an inn...
Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo
Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center
Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...
Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal
Affiliation: Sunnybrook Health Sciences Centre
Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...
Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant
Affiliation: University of Maryland School of Medicine, Maryland University Baltimore
Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...
Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine
Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...
Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...
Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon
Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center
Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...
Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan
Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center
Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...
Authors: Nguyen Phuong Dang, Mason Hazlett, Lijun Ma, Yutaka Natsuaki, William T. Watkins, Zhengzheng Xu, Timothy Pok Chi Yeung
Affiliation: Reflexion Medical Inc,, Radiation Oncology, Keck School of Medicine of USC, RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: This is the first study reporting the beam dosimetric parameter cross-checks of Reflexion linac using different water phantom systems and detectors. The difference in measurements using diffe...
Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal
Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center
Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...
Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao
Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine
Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...
Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez
Affiliation: University of Miami
Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...
Authors: Nema Bassiri, Kristen A. Duke, Neil A. Kirby, Thomas Wilson Klender, Christien Kluwe, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz, Michelle de Oliveira
Affiliation: Miami Cancer Institute, University of Texas HSC San Antonio, UT Health San Antonio
Abstract Preview: Purpose: Determine the practical usability for three phantoms to be used with the ExacTrac Dynamic thermal imaging system. Thermal-guided imaging can be used for inter and intra motion management, pat...
Authors: Yijian Cao, Jenghwa Chang, Nicholas Coupey, Lyu Huang, Jessica Jung
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose:
The Synergy bioabsorbable polymer (BP) stent, made of Platinum Chromium Alloy, is widely utilized in treating coronary artery disease. This study investigates dose perturbations caused by ...
Authors: Yunzhi Ma, Ling Zhuang
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...
Authors: Anthony Hong Cheol Lim, Rayyan L Mahmood, Alexander Stanforth, Chris C. Wang, Mingyao Zhu
Affiliation: Georgia Institute of Technology, Emory University
Abstract Preview: Purpose: The purpose of this project is to test the feasibility of proton minibeam lattice radiotherapy within an existing clinical setting.
Methods:
The TOPAS code is used to model a scenario i...
Authors: Robert A. Corns, Mohammad Kanber
Affiliation: East Carolina University, East Carolina University Brody School of Medicine
Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...
Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell
Affiliation: Mount Sinai Beth Israel
Abstract Preview: Purpose: Commissioning of Flexitron HDR horizontal Leipzig applicators typically includes indirect or direct output verification, using a well chamber specific Revised Correspondence Factor (CFrev) or...
Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...
Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma
Affiliation: University of California San Francisco, University of California, San Francisco, University of California
Abstract Preview: Purpose: Introduced in 2018, the Varian Halcyon platform has increased in popularity due to its reduced cost, user-friendly design, and operational efficiency. As this platform ages, major repairs, in...
Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny
Affiliation: Department of Radiation Oncology, University of Rochester
Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...
Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous
Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...
Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler
Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC
Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...
Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren
Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University
Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...
Authors: Robert A. Dahl
Affiliation: Mayo Foundation
Abstract Preview: Purpose: To develop tools to simplify/accelerate the quality assurance testing of the Mobetron mobile linear accelerator and increase safety when moving it to different OR’s.
Methods: The Mobet...
Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto
Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...
Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...
Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din
Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University
Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...
Authors: Jack Neylon
Affiliation: Department of Radiation Oncology, University of California, Los Angeles
Abstract Preview: Purpose: Commissioning surface applicators is notoriously laborious. In addition, when commissioning Varian surface applicators with vertically positioned source, we found limited data and resources a...
Authors: Paul J. Black, Jordan B Lunsford, James D. Ververs, India Wood
Affiliation: Atrium Health Wake Forest Baptist, Wake Forest University School of Medicine, Wake Forest School of Medicine
Abstract Preview: Purpose:
To develop a 3D-printed modular CT simulator phantom that allows the assessment of all AAPM TG-66 recommended monthly quality assurance (QA) tests.
Methods:
A modular CT simulator mo...
Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...
Authors: Thomas Furno, Arjen Winkel, Ramtin Zakikhani
Affiliation: Genesis Care USA, QLRAD, SMH
Abstract Preview: Purpose: To quantify the dosimetric impact of the newly introduced “Inframammary Fold (IMF) Breast WedgeTM ” device by QLRAD inc. in the region of the inframammary fold during breast radiotherapy.
...
Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison
Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...
Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag
Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia
Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...